Changes in Radial Artery Pulse Pressure During a Fluid Challenge Cannot Assess Fluid Responsiveness in Patients With Septic Shock

被引:5
|
作者
De la Puente-Diaz de Leon, Victor [1 ]
Jaramillo-Rocha, Valente de Jesus [2 ]
Teboul, Jean-Louis [3 ]
Garcia-Miranda, Sofia [4 ]
Martinez-Guerra, Bernardo A. [5 ]
Dominguez-Cherit, Guillermo [1 ]
机构
[1] Inst Nacl Ciencias Med & Nutr Salvador Zubiran, Dept Crit Care Med, Vasco de Quiroga 15, Mexico City, DF, Mexico
[2] Univ Hlth Network, Toronto Gen Hosp, Interdept Div Crit Care, 585 Univ Ave, Toronto, ON M5G 2N2, Canada
[3] Univ Paris Sud, Bicetre Univ Hosp, Med Intens Care Unit, Paris, France
[4] Fdn Clin Med Sur, Dept Internal Med, Mexico City, DF, Mexico
[5] Inst Nacl Ciencias Med & Nutr Salvador Zubiran, Dept Internal Med, Vasco de Quiroga 15, Mexico City, DF, Mexico
关键词
fluid challenge; fluid responsiveness; radial pulse pressure; pulmonary artery catheter; cardiac output; septic shock; CARDIAC-OUTPUT; INTENSIVE-CARE;
D O I
10.1177/0885066617732291
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Arterial blood pressure is the most common variable used to assess the response to a fluid challenge in routine clinical practice. The aim of this study was to evaluate the accuracy of the change in the radial artery pulse pressure (rPP) to detect the change in cardiac output after a fluid challenge in patients with septic shock. Methods: Prospective observational study including 35 patients with septic shock in which rPP and cardiac output were measured before and after a fluid challenge with 400 mL of crystalloid solution. Cardiac output was measured with intermittent thermodilution technique using a pulmonary artery catheter. Patients were divided between responders (increase >15% of cardiac output after fluid challenge) and nonresponders. The area under the receiver operating characteristic curve (AUROC), Pearson correlation coefficient and paired Student t test were used in statistical analysis. Results: Forty-three percent of the patients were fluid responders. The change in rPP could not neither discriminate between responders and nonresponders (AUROC = 0.52; [95% confidence interval: 0.31-0.72] P = .8) nor correlate (r = .21, P = .1) with the change in cardiac output after the fluid challenge. Conclusions: The change in rPP neither discriminated between fluid responders and nonresponders nor correlated with the change in cardiac output after a fluid challenge. The change in rPP cannot serve as a surrogate of the change in cardiac output to assess the response to a fluid challenge in patients with septic shock.
引用
收藏
页码:149 / 153
页数:5
相关论文
共 50 条
  • [41] Pulse-Pressure Variation Predicts Fluid Responsiveness During Heart Displacement for Off-Pump Coronary Artery Bypass Surgery
    Lee, Jong-Hwan
    Jean, Yunseok
    Bahk, Jae-Hyon
    Gil, Nam-Su
    Kim, Ki-Bong
    Hong, Deok Man
    Kim, Hyun Joo
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2011, 25 (06) : 1056 - 1062
  • [42] Effect of two volume responsiveness evaluation methods on fluid resuscitation and prognosis in septic shock patients
    Xu Qianghong
    Yan Jing
    Cai Guolong
    Chen Jin
    Li Li
    Hu Caibao
    CHINESE MEDICAL JOURNAL, 2014, 127 (03) : 483 - 487
  • [43] Easy method to determine fluid responsiveness in septic shock patients: end-tidal CO2 - a prospective observational study
    Ozkarakas, Huseyin
    Ucar, Oguz
    Tekgul, Zeki Tuncel
    Ozmuk, Ozkan
    Ozturk, Mehmet Celal
    Bilgin, Mehmet Ugur
    Samsa, Murat
    Sahinkaya, Halide Hande
    Yesilnacar, Cagri
    ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY, 2024, 30 (02): : 90 - 96
  • [44] Evaluation of the fluid responsiveness in patients with septic shock by ultrasound plus the passive leg raising test
    Wu, Jingyi
    Wang, Zhen
    Wang, Tao
    Yu, Tao
    Yuan, Jing
    Zhang, Qingling
    Lu, Weihua
    Zhang, Xia
    JOURNAL OF SURGICAL RESEARCH, 2018, 224 : 207 - 214
  • [45] Evaluation of ivc and ijv dimensions in prediction of fluid responsiveness in spontaneous breathing patients with septic shock
    A Hasanin
    A Lotfy
    IR Abdel-Aal
    J Elkholey
    A El-Adawy
    H Mohamed
    A Zaghlol
    M Salem
    A Mukhtar
    Intensive Care Medicine Experimental, 3 (Suppl 1)
  • [46] B-type natriuretic peptide, corrected flow time and central venous pressure as predictors of fluid responsiveness in septic shock
    D Sturgess
    R Pascoe
    G Scalia
    B Venkatesh
    Critical Care, 13 (Suppl 1):
  • [47] Extravascular lung water in patients with septic shock during a fluid regimen guided by cardiac index
    Bindels, AJGH
    van der Hoeven, JG
    Meinders, AE
    NETHERLANDS JOURNAL OF MEDICINE, 2000, 57 (03) : 82 - 93
  • [48] The Changes in Pulse Pressure Variation or Stroke Volume Variation After a "Tidal Volume Challenge" Reliably Predict Fluid Responsiveness During Low Tidal Volume Ventilation
    Myatra, Sheila Nainan
    Prabu, Natesh R.
    Vasishtha, Jigeeshu
    Monnet, Xavier
    Kulkarni, Atul Prabhakar
    Teboul, Jean-Louis
    CRITICAL CARE MEDICINE, 2017, 45 (03) : 415 - 421
  • [49] Changes in the mean systemic filling pressure during a fluid challenge in postsurgical intensive care patients
    Maurizio Cecconi
    Hollmann D. Aya
    Martin Geisen
    Claudia Ebm
    Nick Fletcher
    R. Michael Grounds
    Andrew Rhodes
    Intensive Care Medicine, 2013, 39 : 1299 - 1305
  • [50] Efficacy of Left Ventricular Outflow Tract and Carotid Artery Velocity Time Integral as Predictors of Fluid Responsiveness in Patients with Sepsis and Septic Shock
    Chowhan, Ganesh
    Kundu, Riddhi
    Maitra, Souvik
    Arora, Mahesh K.
    Batra, Ravinder K.
    Subramaniam, Rajeshwari
    Baidya, Dalim K.
    Trikha, Anjan
    INDIAN JOURNAL OF CRITICAL CARE MEDICINE, 2021, 25 (03) : 310 - 316