Changes in Radial Artery Pulse Pressure During a Fluid Challenge Cannot Assess Fluid Responsiveness in Patients With Septic Shock

被引:5
|
作者
De la Puente-Diaz de Leon, Victor [1 ]
Jaramillo-Rocha, Valente de Jesus [2 ]
Teboul, Jean-Louis [3 ]
Garcia-Miranda, Sofia [4 ]
Martinez-Guerra, Bernardo A. [5 ]
Dominguez-Cherit, Guillermo [1 ]
机构
[1] Inst Nacl Ciencias Med & Nutr Salvador Zubiran, Dept Crit Care Med, Vasco de Quiroga 15, Mexico City, DF, Mexico
[2] Univ Hlth Network, Toronto Gen Hosp, Interdept Div Crit Care, 585 Univ Ave, Toronto, ON M5G 2N2, Canada
[3] Univ Paris Sud, Bicetre Univ Hosp, Med Intens Care Unit, Paris, France
[4] Fdn Clin Med Sur, Dept Internal Med, Mexico City, DF, Mexico
[5] Inst Nacl Ciencias Med & Nutr Salvador Zubiran, Dept Internal Med, Vasco de Quiroga 15, Mexico City, DF, Mexico
关键词
fluid challenge; fluid responsiveness; radial pulse pressure; pulmonary artery catheter; cardiac output; septic shock; CARDIAC-OUTPUT; INTENSIVE-CARE;
D O I
10.1177/0885066617732291
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Arterial blood pressure is the most common variable used to assess the response to a fluid challenge in routine clinical practice. The aim of this study was to evaluate the accuracy of the change in the radial artery pulse pressure (rPP) to detect the change in cardiac output after a fluid challenge in patients with septic shock. Methods: Prospective observational study including 35 patients with septic shock in which rPP and cardiac output were measured before and after a fluid challenge with 400 mL of crystalloid solution. Cardiac output was measured with intermittent thermodilution technique using a pulmonary artery catheter. Patients were divided between responders (increase >15% of cardiac output after fluid challenge) and nonresponders. The area under the receiver operating characteristic curve (AUROC), Pearson correlation coefficient and paired Student t test were used in statistical analysis. Results: Forty-three percent of the patients were fluid responders. The change in rPP could not neither discriminate between responders and nonresponders (AUROC = 0.52; [95% confidence interval: 0.31-0.72] P = .8) nor correlate (r = .21, P = .1) with the change in cardiac output after the fluid challenge. Conclusions: The change in rPP neither discriminated between fluid responders and nonresponders nor correlated with the change in cardiac output after a fluid challenge. The change in rPP cannot serve as a surrogate of the change in cardiac output to assess the response to a fluid challenge in patients with septic shock.
引用
收藏
页码:149 / 153
页数:5
相关论文
共 50 条
  • [31] Systematic assessment of fluid responsiveness during early septic shock resuscitation: secondary analysis of the ANDROMEDA-SHOCK trial
    Eduardo Kattan
    Gustavo A. Ospina-Tascón
    Jean-Louis Teboul
    Ricardo Castro
    Maurizio Cecconi
    Giorgio Ferri
    Jan Bakker
    Glenn Hernández
    Critical Care, 24
  • [32] Can carotid artery Doppler variations induced by the end-expiratory occlusion maneuver predict fluid responsiveness in septic shock patients?
    Sonia D’Arrigo
    Antonio Maria Dell’Anna
    Claudio Sandroni
    Antonio Messina
    Sofia Cacciola
    Chiara Pacini
    Massimo Antonelli
    Critical Care, 27
  • [33] Prediction of fluid responsiveness in septic shock patients: comparing automated pulse pressure variation by IntelliVue MP monitor and stroke volume variation by FloTrac™/Vigileo™
    B Khwannimit
    R Bhurayanontachai
    Critical Care, 15 (Suppl 1):
  • [34] Disturbed fluid responsiveness and lactate/pyruvate ratio as predictors for mortality of septic shock patients
    Mohamed, Ahmed Abdalla
    Essam, Ahmed
    EGYPTIAN JOURNAL OF ANAESTHESIA, 2016, 32 (04): : 451 - 461
  • [35] Passive leg raising test induced changes in plethysmographic variability index to assess fluid responsiveness in critically ill mechanically ventilated patients with acute circulatory failure
    Mallat, Jihad
    Lemyze, Malcolm
    Fischer, Marc-Olivier
    JOURNAL OF CRITICAL CARE, 2024, 79
  • [36] Right ventricular and pulmonary artery pulse pressure variation and systolic pressure variation for the prediction of fluid responsiveness: an interventional study in coronary artery bypass surgery patients
    Moritz Flick
    Ulrike Sand
    Alina Bergholz
    Karim Kouz
    Beate Reiter
    Doris Flotzinger
    Bernd Saugel
    Jens Christian Kubitz
    Journal of Clinical Monitoring and Computing, 2022, 36 : 1817 - 1825
  • [37] Right ventricular and pulmonary artery pulse pressure variation and systolic pressure variation for the prediction of fluid responsiveness: an interventional study in coronary artery bypass surgery patients
    Flick, Moritz
    Sand, Ulrike
    Bergholz, Alina
    Kouz, Karim
    Reiter, Beate
    Flotzinger, Doris
    Saugel, Bernd
    Kubitz, Jens Christian
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2022, 36 (06) : 1817 - 1825
  • [38] Comparative evaluation of central venous pressure and sonographic inferior vena cava variability in assessing fluid responsiveness in septic shock
    Garg, Manjri
    Sen, Jyotsna
    Goyal, Sandeep
    Chaudhry, Dhruva
    INDIAN JOURNAL OF CRITICAL CARE MEDICINE, 2016, 20 (12) : 708 - 713
  • [39] Pulse Pressure Variation Predicts Fluid Responsiveness in Elderly Patients After Coronary Artery Bypass Graft Surgery
    Yazigi, Alexandre
    Khoury, Eliane
    Hlais, Sani
    Madi-Jebara, Samia
    Haddad, Fadia
    Hayek, Gemma
    Jabbour, Khalil
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2012, 26 (03) : 387 - 390
  • [40] Changes in pulse pressure variation to assess preload responsiveness in mechanically ventilated patients with spontaneous breathing activity: an observational study
    Hamzaoui, Olfa
    Shi, Rui
    Carelli, Simone
    Sztrymf, Benjamin
    Prat, Dominique
    Jacobs, Frederic
    Monnet, Xavier
    Gouezel, Corentin
    Teboul, Jean-Louis
    BRITISH JOURNAL OF ANAESTHESIA, 2021, 127 (04) : 532 - 538