Changes in Radial Artery Pulse Pressure During a Fluid Challenge Cannot Assess Fluid Responsiveness in Patients With Septic Shock

被引:5
|
作者
De la Puente-Diaz de Leon, Victor [1 ]
Jaramillo-Rocha, Valente de Jesus [2 ]
Teboul, Jean-Louis [3 ]
Garcia-Miranda, Sofia [4 ]
Martinez-Guerra, Bernardo A. [5 ]
Dominguez-Cherit, Guillermo [1 ]
机构
[1] Inst Nacl Ciencias Med & Nutr Salvador Zubiran, Dept Crit Care Med, Vasco de Quiroga 15, Mexico City, DF, Mexico
[2] Univ Hlth Network, Toronto Gen Hosp, Interdept Div Crit Care, 585 Univ Ave, Toronto, ON M5G 2N2, Canada
[3] Univ Paris Sud, Bicetre Univ Hosp, Med Intens Care Unit, Paris, France
[4] Fdn Clin Med Sur, Dept Internal Med, Mexico City, DF, Mexico
[5] Inst Nacl Ciencias Med & Nutr Salvador Zubiran, Dept Internal Med, Vasco de Quiroga 15, Mexico City, DF, Mexico
关键词
fluid challenge; fluid responsiveness; radial pulse pressure; pulmonary artery catheter; cardiac output; septic shock; CARDIAC-OUTPUT; INTENSIVE-CARE;
D O I
10.1177/0885066617732291
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Arterial blood pressure is the most common variable used to assess the response to a fluid challenge in routine clinical practice. The aim of this study was to evaluate the accuracy of the change in the radial artery pulse pressure (rPP) to detect the change in cardiac output after a fluid challenge in patients with septic shock. Methods: Prospective observational study including 35 patients with septic shock in which rPP and cardiac output were measured before and after a fluid challenge with 400 mL of crystalloid solution. Cardiac output was measured with intermittent thermodilution technique using a pulmonary artery catheter. Patients were divided between responders (increase >15% of cardiac output after fluid challenge) and nonresponders. The area under the receiver operating characteristic curve (AUROC), Pearson correlation coefficient and paired Student t test were used in statistical analysis. Results: Forty-three percent of the patients were fluid responders. The change in rPP could not neither discriminate between responders and nonresponders (AUROC = 0.52; [95% confidence interval: 0.31-0.72] P = .8) nor correlate (r = .21, P = .1) with the change in cardiac output after the fluid challenge. Conclusions: The change in rPP neither discriminated between fluid responders and nonresponders nor correlated with the change in cardiac output after a fluid challenge. The change in rPP cannot serve as a surrogate of the change in cardiac output to assess the response to a fluid challenge in patients with septic shock.
引用
收藏
页码:149 / 153
页数:5
相关论文
共 50 条
  • [21] Passive leg raising-induced changes in pulse pressure variation to assess fluid responsiveness in mechanically ventilated patients: a multicentre prospective observational study
    Mallat, Jihad
    Fischer, Marc-Olivier
    Granier, Maxime
    Vinsonneau, Christophe
    Jonard, Marie
    Mahjoub, Yazine
    Baghdadi, Fawzi Ali
    Preau, Sebastien
    Poher, Fabien
    Rebet, Olivier
    Bouhemad, Belaid
    Lemyze, Malcolm
    Marzouk, Mehdi
    Besnier, Emmanuel
    Hamed, Fadi
    Rahman, Nadeem
    Abou-Arab, Osama
    Guinot, Pierre-Gregoire
    BRITISH JOURNAL OF ANAESTHESIA, 2022, 129 (03) : 308 - 316
  • [22] Systematic assessment of fluid responsiveness during early septic shock resuscitation: secondary analysis of the ANDROMEDA-SHOCK trial
    Kattan, Eduardo
    Ospina-Tascon, Gustavo A.
    Teboul, Jean-Louis
    Castro, Ricardo
    Cecconi, Maurizio
    Ferri, Giorgio
    Bakker, Jan
    Hernandez, Glenn
    CRITICAL CARE, 2020, 24 (01)
  • [23] Monitoring Changes in Hepatic Venous Velocities Flow after a Fluid Challenge Can Identify Shock Patients Who Lack Fluid Responsiveness
    Du, Wei
    Wang, Xiao-Ting
    Long, Yun
    Liu, Da-Wei
    CHINESE MEDICAL JOURNAL, 2017, 130 (10) : 1202 - 1210
  • [24] Changes in the mean systemic filling pressure during a fluid challenge in postsurgical intensive care patients
    Cecconi, Maurizio
    Aya, Hollmann D.
    Geisen, Martin
    Ebm, Claudia
    Fletcher, Nick
    Grounds, R. Michael
    Rhodes, Andrew
    INTENSIVE CARE MEDICINE, 2013, 39 (07) : 1299 - 1305
  • [25] Can carotid artery Doppler variations induced by the end-expiratory occlusion maneuver predict fluid responsiveness in septic shock patients?
    D'Arrigo, Sonia
    Dell'Anna, Antonio Maria
    Sandroni, Claudio
    Messina, Antonio
    Cacciola, Sofia
    Pacini, Chiara
    Antonelli, Massimo
    CRITICAL CARE, 2023, 27 (01)
  • [26] Pulse pressure variation and prediction of fluid responsiveness in patients ventilated with low tidal volumes
    Alves de Oliveira-Costa, Clarice Daniele
    Friedman, Gilberto
    Rios Vieira, Silvia Regina
    Fialkow, Lea
    CLINICS, 2012, 67 (07) : 773 - 778
  • [27] Decrease in pulse pressure and stroke volume variations after mini-fluid challenge accurately predicts fluid responsiveness
    Mallat, J.
    Meddour, M.
    Durville, E.
    Lemyze, M.
    Pepy, F.
    Temime, J.
    Vangrunderbeeck, N.
    Tronchon, L.
    Thevenin, D.
    Tavernier, B.
    BRITISH JOURNAL OF ANAESTHESIA, 2015, 115 (03) : 449 - 456
  • [28] Predictive value of pulse pressure variation for fluid responsiveness in septic patients using lung-protective ventilation strategies
    Freitas, F. G. R.
    Bafi, A. T.
    Nascente, A. P. M.
    Assuncao, M.
    Mazza, B.
    Azevedo, L. C. P.
    Machado, F. R.
    BRITISH JOURNAL OF ANAESTHESIA, 2013, 110 (03) : 402 - 408
  • [29] Pulse pressure variation predicts fluid responsiveness following coronary artery bypass surgery
    Kramer, A
    Zygun, D
    Hawes, H
    Easton, P
    Ferland, A
    CHEST, 2004, 126 (05) : 1563 - 1568
  • [30] Reliability of central venous pressure to assess left ventricular preload for fluid resuscitation in patients with septic shock
    Sasai T.
    Tokioka H.
    Fukushima T.
    Mikane T.
    Oku S.
    Iwasaki E.
    Ishii M.
    Mieda H.
    Ishikawa T.
    Minami E.
    Journal of Intensive Care, 2 (1)