Changes in Radial Artery Pulse Pressure During a Fluid Challenge Cannot Assess Fluid Responsiveness in Patients With Septic Shock

被引:5
|
作者
De la Puente-Diaz de Leon, Victor [1 ]
Jaramillo-Rocha, Valente de Jesus [2 ]
Teboul, Jean-Louis [3 ]
Garcia-Miranda, Sofia [4 ]
Martinez-Guerra, Bernardo A. [5 ]
Dominguez-Cherit, Guillermo [1 ]
机构
[1] Inst Nacl Ciencias Med & Nutr Salvador Zubiran, Dept Crit Care Med, Vasco de Quiroga 15, Mexico City, DF, Mexico
[2] Univ Hlth Network, Toronto Gen Hosp, Interdept Div Crit Care, 585 Univ Ave, Toronto, ON M5G 2N2, Canada
[3] Univ Paris Sud, Bicetre Univ Hosp, Med Intens Care Unit, Paris, France
[4] Fdn Clin Med Sur, Dept Internal Med, Mexico City, DF, Mexico
[5] Inst Nacl Ciencias Med & Nutr Salvador Zubiran, Dept Internal Med, Vasco de Quiroga 15, Mexico City, DF, Mexico
关键词
fluid challenge; fluid responsiveness; radial pulse pressure; pulmonary artery catheter; cardiac output; septic shock; CARDIAC-OUTPUT; INTENSIVE-CARE;
D O I
10.1177/0885066617732291
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Arterial blood pressure is the most common variable used to assess the response to a fluid challenge in routine clinical practice. The aim of this study was to evaluate the accuracy of the change in the radial artery pulse pressure (rPP) to detect the change in cardiac output after a fluid challenge in patients with septic shock. Methods: Prospective observational study including 35 patients with septic shock in which rPP and cardiac output were measured before and after a fluid challenge with 400 mL of crystalloid solution. Cardiac output was measured with intermittent thermodilution technique using a pulmonary artery catheter. Patients were divided between responders (increase >15% of cardiac output after fluid challenge) and nonresponders. The area under the receiver operating characteristic curve (AUROC), Pearson correlation coefficient and paired Student t test were used in statistical analysis. Results: Forty-three percent of the patients were fluid responders. The change in rPP could not neither discriminate between responders and nonresponders (AUROC = 0.52; [95% confidence interval: 0.31-0.72] P = .8) nor correlate (r = .21, P = .1) with the change in cardiac output after the fluid challenge. Conclusions: The change in rPP neither discriminated between fluid responders and nonresponders nor correlated with the change in cardiac output after a fluid challenge. The change in rPP cannot serve as a surrogate of the change in cardiac output to assess the response to a fluid challenge in patients with septic shock.
引用
收藏
页码:149 / 153
页数:5
相关论文
共 50 条
  • [1] Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock
    Feissel, M
    Michard, F
    Mangin, I
    Ruyer, O
    Faller, JP
    Teboul, JL
    CHEST, 2001, 119 (03) : 867 - 873
  • [2] Accuracy or cumulative volumes of fluid challenge to assess fluid responsiveness in critically ill patients with acute circulatory failure: a pharmacodynamic approach
    Barthelemy, Romain
    Kindermans, Manuel
    Delval, Paul
    Collet, Magalie
    Gaugain, Samuel
    Cecconi, Maurizio
    Mebazaa, Alexandre
    Chousterman, Benjamin G.
    BRITISH JOURNAL OF ANAESTHESIA, 2022, 128 (02) : 236 - 243
  • [4] Sublingual microcirculatory response to fluid challenge in septic shock patients
    M Losser
    V Cirillo
    C Barbanti
    D Payen
    Critical Care, 8 (Suppl 1):
  • [5] Changes of central venous oxygen saturation define fluid responsiveness in patients with septic shock: A prospective observational study
    Xu, Biao
    Yang, Xiaobo
    Wang, Chunyao
    Jiang, Wei
    Weng, Li
    Hu, Xiaoyun
    Peng, Jinmin
    Du, Bin
    JOURNAL OF CRITICAL CARE, 2017, 38 : 13 - 19
  • [6] RESPIRATORY VARIABILITY OF VALVULAR PEAK SYSTOLIC VELOCITY AS A NEW INDICATOR OF FLUID RESPONSIVENESS IN PATIENTS WITH SEPTIC SHOCK
    Ma, Qiang
    Ding, Caiyun
    Jiang, Feng
    Hu, Guobin
    Wu, Jingyi
    Zhang, Xia
    SHOCK, 2023, 60 (01): : 11 - 17
  • [7] Methods of assessing fluid responsiveness in septic shock patients: a narrative review
    Weigl, Wojciech
    Adamski, Jan
    Onichimowski, Dariusz
    Nowakowski, Piotr
    Wagner, Bodo
    ANAESTHESIOLOGY INTENSIVE THERAPY, 2022, 54 (02) : 175 - 183
  • [8] Stroke volume variation does not predict fluid responsiveness in patients with septic shock on pressure support ventilation
    Perner, A.
    Faber, T.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2006, 50 (09) : 1068 - 1073
  • [9] The ability of pulse oximetry-derived peripheral perfusion index to detect fluid responsiveness in patients with septic shock
    Ahmed Hasanin
    Nadia Karam
    Ahmed M. Mukhtar
    Sara F. Habib
    Journal of Anesthesia, 2021, 35 : 254 - 261
  • [10] The ability of pulse oximetry-derived peripheral perfusion index to detect fluid responsiveness in patients with septic shock
    Hasanin, Ahmed
    Karam, Nadia
    Mukhtar, Ahmed M.
    Habib, Sara F.
    JOURNAL OF ANESTHESIA, 2021, 35 (02) : 254 - 261