Determination of Zn(II) in natural waters by ICP-OES with on-line preconcentration using a simple solid phase extraction system

被引:52
作者
Escudero, Luis A. [1 ,2 ]
Martinez, Luis D. [1 ,2 ]
Salonia, Jose A. [1 ]
Gasquez, Jose A. [1 ]
机构
[1] Univ Nacl San Luis, Area Quim Analit, Dept Quim, Fac Quim Bioquim & Farm, San Luis, Argentina
[2] Consejo Nacl Invest Cient & Tecn, Buenos Aires, Argentina
关键词
Zinc determination; On-line preconcentration; ICP-OES; EVA; ATOMIC-ABSORPTION-SPECTROMETRY; HEAVY-METAL IONS; TRACE AMOUNTS; BIOLOGICAL SAMPLES; SILICA-GEL; ENVIRONMENTAL-SAMPLES; PACKED MINICOLUMN; CARBON NANOTUBES; ACTIVATED CARBON; KNOTTED REACTOR;
D O I
10.1016/j.microc.2009.11.003
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An on-line zinc preconcentration and determination system implemented with inductively coupled plasma optical emission spectrometry (ICP-OES) was developed The zinc was precipitated and retained on a minicolumn filled with ethyl vinyl acetate (EVA) at pH 90, without using any complexing reagent The zinc ions were eluted from the minicolumn with 10% (v/v) hydrochloric acid. Experimental conditions including pH and sample loading and eluting variables were evaluated and established An enrichment factor (EF) of 44 was obtained for Zn2+ with a preconcentration time of 120 s Under the optimal conditions, the value of the limit of detection (3 sigma) for the preconcentration of 10 mL of sample was 008 mu g L-1 The sampling frequency was about 24 h(-1) The precision for six replicate determinations (repeatability conditions) at 50 mu g L-1 Zn level was 3 94% relative deviation standard (RSD), calculated from the peak heights obtained The methodology was successfully applied to the determination of zinc in tap water samples and in a certified VKI reference material QC Metal LL1 DHI (Water & Environment) Denmark (C) 2009 Elsevier B V All rights reserved.
引用
收藏
页码:164 / 168
页数:5
相关论文
共 32 条
[1]   A novel microextraction technique based on 1-hexylpyridinium hexafluorophosphate ionic liquid for the preconcentration of zinc in water and milk samples [J].
Abdolmohammad-Zadeh, H. ;
Sadeghi, G. H. .
ANALYTICA CHIMICA ACTA, 2009, 649 (02) :211-217
[2]   Simultaneous determination of Cd, Cu, Mn, Ni, Pb and Zn in nail samples by inductively coupled plasma mass spectrometry (ICP-MS) after tetramethylammonium hydroxide solubilization at room temperature: Comparison with ETAAS [J].
Batista, Bruno L. ;
Rodrigues, Jairo L. ;
Nunes, Juliana A. ;
Tormen, Luciano ;
Curtius, Adilson J. ;
Barbosa, Fernando, Jr. .
TALANTA, 2008, 76 (03) :575-579
[3]   Recent on-line processing procedures for biological samples for determination of trace elements by atomic spectrometric methods [J].
Burguera, Jose L. ;
Burguera, Marcela .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2009, 64 (06) :451-458
[4]   Use of 8-hydroxyquinoline-chitosan chelating resin in an automated on-line preconcentration system for determination of zinc(II) by F AAS [J].
Carletto, Jeferson Schneider ;
Di Pietro Roux, Kalya Cravo ;
Maltez, Heloisa Franca ;
Martendal, Edmar ;
Carasek, Eduardo .
JOURNAL OF HAZARDOUS MATERIALS, 2008, 157 (01) :88-93
[5]   ICP-OES determination of trace metal ions after preconcentration by 4-(8-hydroxy-5-quinolylazo)naphthalenesulfonic acid modified silica gel [J].
Chang, Xijun ;
Luo, Haixia ;
Cui, Yuemei ;
Zhu, Xiangbing ;
Zhai, Yunhui ;
Hu, Zheng ;
He, Qun .
JOURNAL OF MOLECULAR STRUCTURE, 2008, 891 (1-3) :45-49
[6]   Development of an on-line preconcentration system for zinc determination in biological samples [J].
Dutra, RL ;
Maltez, HF ;
Carasek, E .
TALANTA, 2006, 69 (02) :488-493
[7]  
Escudero L, 2008, ATOM SPECTROSC, V29, P21
[8]   Preconcentration and separation of trace amount of heavy metal ions on bis(2-hydroxy acetophenone)ethylendiimine loaded on activated carbon [J].
Ghaedi, M. ;
Shokrollahi, A. ;
Kianfar, A. H. ;
Pourfarokhi, A. ;
Khanjari, N. ;
Mirsadeghi, A. S. ;
Soylak, M. .
JOURNAL OF HAZARDOUS MATERIALS, 2009, 162 (2-3) :1408-1414
[9]   The determination of some heavy metals in food samples by flame atomic absorption spectrometry after their separation-preconcentration on bis salicyl aldehyde, 1,3 propan diimine (BSPDI) loaded on activated carbon [J].
Ghaedi, M. ;
Shokrollahi, A. ;
Kianfar, A. H. ;
Mirsadeghi, A. S. ;
Pourfarokhi, A. ;
Soylak, M. .
JOURNAL OF HAZARDOUS MATERIALS, 2008, 154 (1-3) :128-134
[10]   A solid phase extraction procedure for Fe3+, Cu2+ and Zn2+ ions on 2-phenyl-1H-benzo[d] imidazole loaded on Triton X-100-coated polyvinyl chloride [J].
Ghaedi, Mehrorang ;
Niknam, Khodabakhsh ;
Shokrollahi, Ardeshir ;
Niknam, Ebrahim ;
Ghaedi, Hamed ;
Soylak, Mustafa .
JOURNAL OF HAZARDOUS MATERIALS, 2008, 158 (01) :131-136