Technical standardization of ICG near-infrared fluorescence (NIRF) laparoscopic partial nephrectomy for duplex kidney in pediatric patients

被引:18
作者
Esposito, Ciro [1 ]
Autorino, Giuseppe [1 ]
Coppola, Vincenzo [1 ]
Esposito, Giorgia [1 ]
Paternoster, Mariano [2 ]
Castagnetti, Marco [3 ]
Cardone, Roberto [1 ]
Cerulo, Mariapina [1 ]
Borgogni, Rachele [1 ]
Cortese, Giuseppe [1 ]
Escolino, Maria [1 ]
机构
[1] Federico II Univ Naples, Div Pediat Surg, Via Pansini 5, I-80131 Naples, Italy
[2] Federico II Univ Naples, Dept Adv Biomed Sci, Naples, Italy
[3] Univ Padua, Div Pediat Urol, Padua, Italy
关键词
Indocyanine green; ICG; Fluorescence; Partial nephrectomy; Children; Laparoscopy; INDOCYANINE GREEN ICG; CHILDREN; INFANTS;
D O I
10.1007/s00345-021-03759-6
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose This study aimed to standardize the operative technique of indocyanine green (ICG) near-infrared fluorescence (NIRF) laparoscopic partial nephrectomy (LPN) and compare it with the standard technique. Methods In the last 4 years, we performed 22 LPN (14 right-sided, 8 left-sided) in children with non-functioning moiety of duplex kidney. Patients included 12 girls and 10 boys with a median age of 3.9 years (range 1-10). Patients were grouped according to the use of ICG-NIRF: G1 included 12 patients operated using ICG-NIRF and G2 included 10 patients receiving the standard technique. We standardized the technique of injection of ICG in three different steps. Results The median operative time was significantly lower in G1 [87 min (range 68-110)] compared with G2 [140 min (range 70-220)] (p = 0.001). One intra-operative complication occurred in G2. At post-operative ultrasound (US), the residual moiety was normal in all patients. An asymptomatic renal cyst related to the site of surgery was visualized at US in 8/22 (36%), with a significantly higher incidence in G2 (6/10, 60%) compared with G1 (2/12, 16.6%) (p = 0.001). Renogram demonstrated no loss of function of residual moiety. No allergic reactions to ICG occurred. Conclusion ICG-NIRF LPN is technically easier, quicker, and safer compared with the standard technique. The main advantages of using ICG-NIRF during LPN are the clear identification of normal ureter, vasculature of non-functioning pole, and demarcation line between the avascular and the perfused pole. The main limitation of ICG technology remains the need for specific laparoscopic equipment that is not always available.
引用
收藏
页码:4167 / 4173
页数:7
相关论文
共 25 条
[1]   Optimization of Near Infrared Fluorescence Tumor Localization during Robotic Partial Nephrectomy [J].
Angell, Jordan E. ;
Khemees, Tariq A. ;
Abaza, Ronney .
JOURNAL OF UROLOGY, 2013, 190 (05) :1668-1673
[2]   Current Applications of Near-infrared Fluorescence Imaging in Robotic Urologic Surgery: A Systematic Review and Critical Analysis of the Literature [J].
Autorino, Riccardo ;
Zargar, Homayoun ;
White, Wesley M. ;
Novara, Giacomo ;
Annino, Filippo ;
Perdona, Sisto ;
De Angelis, Michele ;
Mottrie, Alexandre ;
Porpiglia, Francesco ;
Kaouk, Jihad H. .
UROLOGY, 2014, 84 (04) :751-759
[3]   Occurrence of Severe Hypotension After Indocyanine Green Injection During the Intraoperative Period [J].
Bjerregaard, Jens ;
Pandia, Mihir P. ;
Jaffe, Richard A. .
A & A CASE REPORTS, 2013, 1 (01) :26-30
[4]   Near-Infrared Fluorescence Imaging with Intraoperative Administration of Indocyanine Green for Robotic Partial Nephrectomy [J].
Bjurlin, Marc A. ;
McClintock, Tyler R. ;
Stifelman, Michael D. .
CURRENT UROLOGY REPORTS, 2015, 16 (04)
[5]   Clinical applications of indocyanine green (ICG) enhanced fluorescence in laparoscopic surgery [J].
Boni, Luigi ;
David, Giulia ;
Mangano, Alberto ;
Dionigi, Gianlorenzo ;
Rausei, Stefano ;
Spampatti, Sebastiano ;
Cassinotti, Elisa ;
Fingerhut, Abe .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2015, 29 (07) :2046-2055
[6]  
Chu W, 2017, UROL CASE REP, V12, P37, DOI 10.1016/j.eucr.2017.02.006
[7]   Fluorescence properties and metabolic features of indocyanine green (ICG) as related to angiography [J].
Desmettre, T ;
Devoisselle, JM ;
Mordon, S .
SURVEY OF OPHTHALMOLOGY, 2000, 45 (01) :15-27
[8]   Cyanine dyes as contrast agents for near-infrared imaging in vivo: acute tolerance, pharmacokinetics, and fluorescence imaging [J].
Ebert, Bernd ;
Riefke, Bjoern ;
Sukowski, Uwe ;
Kai Licha .
JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (06)
[9]   Near-Infrared fluorescence imaging using indocyanine green (ICG): Emerging applications in pediatric urology [J].
Esposito, Ciro ;
Coppola, Vincenzo ;
Del Conte, Fulvia ;
Cerulo, Mariapina ;
Esposito, Giorgia ;
Farina, Alessandra ;
Crocetto, Felice ;
Castagnetti, Marco ;
Settimi, Alessandro ;
Escolino, Maria .
JOURNAL OF PEDIATRIC UROLOGY, 2020, 16 (05) :700-707
[10]   Image-Guided Pediatric Surgery Using Indocyanine Green (ICG) Fluorescence in Laparoscopic and Robotic Surgery [J].
Esposito, Ciro ;
Settimi, Alessandro ;
Del Conte, Fulvia ;
Cerulo, Mariapina ;
Coppola, Vincenzo ;
Farina, Alessandra ;
Crocetto, Felice ;
Ricciardi, Elisabetta ;
Esposito, Giovanni ;
Escolino, Maria .
FRONTIERS IN PEDIATRICS, 2020, 8