Elastographic imaging of low-contrast elastic modulus distributions in tissue

被引:76
作者
Kallel, F
Ophir, J
Magee, K
Krouskop, T
机构
[1] Univ Texas, Sch Med, Ultrason Lab, Dept Radiol, Houston, TX 77030 USA
[2] Baylor Coll Med, Dept Phys Med & Rehabil, Houston, TX 77030 USA
关键词
elasticity; imaging; ultrasound; elastography; strain; Young's modulus; low-contrast; kidney; prostate;
D O I
10.1016/S0301-5629(97)00287-1
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Elastography is a new ultrasonic imaging technique that produces images of the strain distribution in compliant tissues, This strain distribution is derived from ultrasonically estimated longitudinal internal motion induced by an external compression of the tissue, The displayed two-dimensional (2-D) images are called elastograms, In this paper, it is demonstrated that, when signal-to-noise ratio-enhancing techniques are used, elastography is capable of imaging low-contrast elastic modulus tissue structures with high contrast-to-noise ratios, This is demonstrated using both computer simulations and data obtained from 3 days postmortem ovine kidneys in vitro, The elastograms of such organs suggest that the modulus slowly decays from the renal cortex (RC) to the interior of the renal sinus (RS), Such modulus variation is corroborated by independent measurements of the Young's moduli, It is found that the RC is approximately twice as hard as the interior of the RS, We invoke our previous results on elastographic contrast-transfer efficiency to demonstrate that, at low contrast, the elastogram may be interpreted as a quantitative image of the relative Young's modulus distribution. (C) 1998 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:409 / 425
页数:17
相关论文
共 33 条
  • [1] ALAM K, 1997, ULTRASOUND MED BIOL, V23, P95
  • [2] ANDERSON WAD, 1953, PATHOLOGY
  • [3] Error analysis in acoustic elastography .2. Strain estimation and SNR analysis
    Bilgen, M
    Insana, MF
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1997, 101 (02) : 1147 - 1154
  • [4] CESPEDES EI, 1993, THESIS U HOUSTON HOU
  • [5] METHODS FOR ESTIMATION OF SUBSAMPLE TIME DELAYS OF DIGITIZED ECHO SIGNALS
    CESPEDES, I
    HUANG, Y
    OPHIR, J
    SPRATT, S
    [J]. ULTRASONIC IMAGING, 1995, 17 (02) : 142 - 171
  • [6] ELASTOGRAPHY - ELASTICITY IMAGING USING ULTRASOUND WITH APPLICATION TO MUSCLE AND BREAST IN-VIVO
    CESPEDES, I
    OPHIR, J
    PONNEKANTI, H
    MAKLAD, N
    [J]. ULTRASONIC IMAGING, 1993, 15 (02) : 73 - 88
  • [7] THEORETICAL BOUNDS ON STRAIN ESTIMATION IN ELASTOGRAPHY
    CESPEDES, I
    INSANA, M
    OPHIR, J
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1995, 42 (05) : 969 - 972
  • [8] 2-D companding for noise reduction in strain imaging
    Chaturvedi, P
    Insana, MF
    Hall, TJ
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (01) : 179 - 191
  • [9] ELASTICITY IMAGING FOR EARLY DETECTION OF RENAL PATHOLOGY
    EMELIANOV, SY
    LUBINSKI, MA
    WEITZEL, WF
    WIGGINS, RC
    SKOVORODA, AR
    ODONNELL, M
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (07) : 871 - 883
  • [10] FUNG YC, 1981, BIOMECHANICAL PROPER, V196, P260