Thermoacoustic Stirling power generation from LNG cold energy and low-temperature waste heat

被引:43
作者
Wang, Kai [1 ,2 ]
Dubey, Swapnil [1 ]
Choo, Fook Hoong [1 ]
Duan, Fei [2 ]
机构
[1] Nanyang Technol Univ, Energy Res Inst NTU, Singapore 637141, Singapore
[2] Nanyang Technol Univ, Sch Mech & Aerosp Engn, Singapore 639798, Singapore
基金
新加坡国家研究基金会;
关键词
Stirling engine; Thermoacoustic engine; Liquefied natural gas; Cold energy; Waste heat; Linear alternator; LIQUEFIED NATURAL-GAS; ELECTRIC GENERATOR; THERMODYNAMIC ANALYSIS; PERFORMANCE ANALYSIS; ENGINE DRIVEN; CYCLE; EXERGY; OPTIMIZATION; OPERATION; ONSET;
D O I
10.1016/j.energy.2017.03.124
中图分类号
O414.1 [热力学];
学科分类号
摘要
Recovering cold energy generated in the regasification process of liquefied natural gas (LNG) can help to improve the energy efficiency of LNG power generation systems, meanwhile, abundant low-grade waste heat can also be exploited from the exhaust gas of gas turbines. This study proposes to apply the thermoacoustic Stirling electric generator to recover LNG cold energy and waste heat simultaneously. A pair of linear alternators is directly coupled with the thermoacoustic loop by replacing the long and bulky resonator completely. Numerical simulation is conducted on the basis of the thermoacoustic theory to characterize and optimize the operations of the system. The effects of the back volumes of linear alternators, feedback tube length and regenerator length on the output performances are investigated. The distributions of key parameters, including pressure, volume flow rate, phase difference, acoustic power and exergy flow, are further studied. One design of the thermoacoustic Stirling electric generator operated with 4 MPa helium gas is capable of generating 2.3 kW electric power with the highest exergy efficiency of 0.253 when the cold and hot ends are maintained at 110 K and 500 K. Performances can be further improved if the conversion efficiency of the linear alternators is further increased. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:280 / 290
页数:11
相关论文
共 52 条
[1]   Numerical investigation of a looped-tube travelling-wave thermoacoustic engine with a bypass pipe [J].
Al-Kayiem, Ali ;
Yu, Zhibin .
ENERGY, 2016, 112 :111-120
[2]  
[Anonymous], 2015, BP Statistical Review of World Energy June 2015
[3]   A thermoacoustic Stirling heat engine [J].
Backhaus, S ;
Swift, GW .
NATURE, 1999, 399 (6734) :335-338
[4]   Traveling-wave thermoacoustic electric generator [J].
Backhaus, S ;
Tward, E ;
Petach, M .
APPLIED PHYSICS LETTERS, 2004, 85 (06) :1085-1087
[5]  
Bi T., 2015, APPL ENERG, V185, P1355
[6]  
De Blok K, 2012, 19 INT C SOUND VIBR
[7]   Using cryogenic exergy of liquefied natural gas for electricity production with the Stirling cycle [J].
Dong, Hui ;
Zhao, Liang ;
Zhang, Songyuan ;
Wang, Aihua ;
Cai, Jiuju .
ENERGY, 2013, 63 :10-18
[8]  
Duan F, 2016, PCTSG2016050446
[9]   Combined cascaded Rankine and direct expander based power units using LNG (liquefied natural gas) cold as heat sink in LNG regasification [J].
Ferreiro Garcia, Ramon ;
Carbia Carril, Jose ;
Romero Gomez, Javier ;
Romero Gomez, Manuel .
ENERGY, 2016, 105 :16-24
[10]   Working fluid selection and electrical performance optimisation of a domestic solar-ORC combined heat and power system for year-round operation in the UK [J].
Freeman, James ;
Hellgardt, Klaus ;
Markides, Christos N. .