Total hip replacement using a highly cross-linked polyethylene liner in Asians with small acetabulum

被引:6
|
作者
Chua, Weiliang [1 ]
Roy, Shuvendu [1 ]
Sng, Jonathan [1 ]
Liang, Shen [1 ]
Das De, Shamal [1 ]
机构
[1] Natl Univ Singapore Hosp, Singapore 119074, Singapore
来源
JOURNAL OF ORTHOPAEDIC SURGERY | 2014年 / 22卷 / 03期
关键词
arthroplasty; replacement; hip; osteolysis; polyethylene; MOLECULAR-WEIGHT POLYETHYLENE; FEMORAL-HEAD; FOLLOW-UP; WEAR; ARTHROPLASTY; OSTEOLYSIS; ASSOCIATION; COMPONENTS; REVISION; QUALITY;
D O I
10.1177/230949901402200315
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose. To evaluate the medium-term outcomes of total hip replacement (THR) using a thin highly cross-linked polyethylene (HXLPE) liner in an Asian population. Methods. Medical records of 20 men and 44 women aged 26 to 80 (mean, 59) years who underwent 80 THRs using a thin HXLPE liner by a single surgeon were reviewed. Indications for THR included dysplasia (n= 26), avascular necrosis (n= 26), osteoarthritis (n= 22), rheumatoid arthritis (n= 4), and ankylosing spondylitis (n= 2). The surgical technique, implant used, and rehabilitation protocol were standardised. Radiographs were evaluated for cup migration and peri-implant radiolucency. Femoral head penetration was assessed at day 1 and last follow-up using the Kang modification of the Dorr and Wan method and the PowerPoint method. Results. After a mean follow-up of 7.5 (range, 5.0-11.9) years, no patient had undergone acetabular revision. Two hips were revised for the femoral stem. Femoral head penetration did not correlate with sex, age at surgery, hip pathology, acetabular inclination angle, cup size, or liner thickness. The maximum femoral head penetration was 0.09 mm/year, which was below the osteolysis threshold of 0.1 mm/year. The mean +/- standard deviation femoral head penetration was 0.29 +/- 0.12 mm (or 0.04 +/- 0.02 mm/year) by the PowerPoint method and 0.17 +/- 0.22 mm (or 0.02 +/- 0.03 mm/year) by the Kang modification of the Dorr and Wan method. Femoral head penetration correlated with the number of years of follow-up (p= 0.012). Conclusion. The use of a thin HXLPE liner in primary THR for patients with small acetabulum achieved good outcomes after a mean of 7.5 years.
引用
收藏
页码:342 / 346
页数:5
相关论文
共 50 条
  • [41] Clinical Results of the Wear Performance of Cross-Linked Polyethylene in Total Hip Arthroplasty Prospective Randomized Trial
    Ise, Kentaro
    Kawanabe, Keiichi
    Tamura, Jiro
    Akiyama, Haruhiko
    Goto, Koji
    Nakamura, Takashi
    JOURNAL OF ARTHROPLASTY, 2009, 24 (08) : 1216 - 1220
  • [42] Wear testing of a canine hip resurfacing implant that uses highly cross-linked polyethylene
    Warburton, Kevin J.
    Everingham, John B.
    Helms, Jillian L.
    Kazanovicz, Andrew J.
    Hollar, Katherine A.
    Brourman, Jeff D.
    Fox, Steven M.
    Lujan, Trevor J.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2018, 36 (04) : 1196 - 1205
  • [43] Late failure of annealed highly cross-linked polyethylene acetabular liner
    Hara, Daisuke
    Nakashima, Yasuharu
    Yamamoto, Takuaki
    Higashihara, Shinshichiro
    Todo, Mitsugu
    Hirata, Masanobu
    Akiyama, Mio
    Iwamoto, Yukihide
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2013, 28 : 206 - 212
  • [44] Wear Analysis of Second-generation Highly Cross-Linked Polyethylene in Primary Total Hip Arthroplasty
    Samujh, Christopher
    Bhimani, Samrath
    Smith, Langan
    Malkani, Arthur L.
    ORTHOPEDICS, 2016, 39 (06) : E1178 - E1182
  • [45] Manufacturing, oxidation, mechanical properties and clinical performance of highly cross-linked polyethylene in total hip arthroplasty
    Singh, Gurpreet
    Klassen, Robert
    Howard, James
    Naudie, Douglas
    Teeter, Matthew
    Lanting, Brent
    HIP INTERNATIONAL, 2018, 28 (06) : 573 - 583
  • [46] Damage of an Oxinium femoral head and polyethylene liner following 'routine' total hip replacement
    McCalden, R. W.
    Charron, K. D.
    Davidson, R. D.
    Teeter, M. G.
    Holdsworth, D. W.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (03): : 409 - 413
  • [47] Does cross-linked polyethylene decrease the revision rate of total hip arthroplasty compared with conventional polyethylene? A meta-analysis
    Shen, C.
    Tang, Z. -H.
    Hu, J. -Z.
    Zou, G. -Y.
    Xiao, R. -C.
    Yan, D. -X.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2014, 100 (07) : 745 - 750
  • [48] Highly Cross-Linked Polyethylene in Total Hip Arthroplasty in Patients Younger Than 50 Years With Osteonecrosis of the Femoral Head: A Minimum of 10 Years of Follow-Up
    Min, Byung-Woo
    Cho, Chul-Hyun
    Son, Eun-Suck
    Lee, Kyung-Jae
    Lee, Si-Wook
    Song, Kwang-Soon
    JOURNAL OF ARTHROPLASTY, 2020, 35 (03) : 805 - 810
  • [49] Femoral Head Penetration Rates and Oxidation of Highly Cross-Linked Polyethylene Hip Liners Implanted More Than 10 Years
    Derr, Tabitha
    MacDonald, Daniel W.
    Malkani, Arthur L.
    Klein, Gregg R.
    Kurtz, Steven M.
    JOURNAL OF ARTHROPLASTY, 2024, 39 (09) : S286 - S291
  • [50] The Lawrence D. Dorr Surgical Techniques & Technologies Award: Using Big Heads and Small Acetabular Components With Highly Cross-Linked Polyethylene in Total Hip Arthroplasty: Is It Safe?
    Baker, Courtney E.
    Bukowski, Brandon R.
    Abdel, Matthew P.
    Trousdale, Robert T.
    JOURNAL OF ARTHROPLASTY, 2021, 36 (07) : S11 - S17