Total hip replacement using a highly cross-linked polyethylene liner in Asians with small acetabulum

被引:6
|
作者
Chua, Weiliang [1 ]
Roy, Shuvendu [1 ]
Sng, Jonathan [1 ]
Liang, Shen [1 ]
Das De, Shamal [1 ]
机构
[1] Natl Univ Singapore Hosp, Singapore 119074, Singapore
来源
JOURNAL OF ORTHOPAEDIC SURGERY | 2014年 / 22卷 / 03期
关键词
arthroplasty; replacement; hip; osteolysis; polyethylene; MOLECULAR-WEIGHT POLYETHYLENE; FEMORAL-HEAD; FOLLOW-UP; WEAR; ARTHROPLASTY; OSTEOLYSIS; ASSOCIATION; COMPONENTS; REVISION; QUALITY;
D O I
10.1177/230949901402200315
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose. To evaluate the medium-term outcomes of total hip replacement (THR) using a thin highly cross-linked polyethylene (HXLPE) liner in an Asian population. Methods. Medical records of 20 men and 44 women aged 26 to 80 (mean, 59) years who underwent 80 THRs using a thin HXLPE liner by a single surgeon were reviewed. Indications for THR included dysplasia (n= 26), avascular necrosis (n= 26), osteoarthritis (n= 22), rheumatoid arthritis (n= 4), and ankylosing spondylitis (n= 2). The surgical technique, implant used, and rehabilitation protocol were standardised. Radiographs were evaluated for cup migration and peri-implant radiolucency. Femoral head penetration was assessed at day 1 and last follow-up using the Kang modification of the Dorr and Wan method and the PowerPoint method. Results. After a mean follow-up of 7.5 (range, 5.0-11.9) years, no patient had undergone acetabular revision. Two hips were revised for the femoral stem. Femoral head penetration did not correlate with sex, age at surgery, hip pathology, acetabular inclination angle, cup size, or liner thickness. The maximum femoral head penetration was 0.09 mm/year, which was below the osteolysis threshold of 0.1 mm/year. The mean +/- standard deviation femoral head penetration was 0.29 +/- 0.12 mm (or 0.04 +/- 0.02 mm/year) by the PowerPoint method and 0.17 +/- 0.22 mm (or 0.02 +/- 0.03 mm/year) by the Kang modification of the Dorr and Wan method. Femoral head penetration correlated with the number of years of follow-up (p= 0.012). Conclusion. The use of a thin HXLPE liner in primary THR for patients with small acetabulum achieved good outcomes after a mean of 7.5 years.
引用
收藏
页码:342 / 346
页数:5
相关论文
共 50 条
  • [31] Conventional Versus Cross-Linked Polyethylene for Total Hip Arthroplasty
    Surace, Michele F.
    Monestier, Luca
    Vulcano, Ettore
    Harwin, Steven F.
    Cherubino, Paolo
    ORTHOPEDICS, 2015, 38 (09) : 556 - 561
  • [32] Cross-linked versus conventional polyethylene for total knee arthroplasty: a meta-analysis
    Yu, Bin-feng
    Yang, Guo-jing
    Wang, Wei-liang
    Zhang, Lei
    Lin, Xi-peng
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2016, 11
  • [33] Sequentially Irradiated and Annealed Highly Cross-Linked Polyethylene: Linear Vector and Volumetric Wear in Total Hip Arthroplasty at 10 Years
    Remily, Ethan A.
    Douglas, Scott J.
    Sax, Oliver C.
    Pervaiz, Sahir S.
    Mohamed, Nequesha S.
    Wilkie, Wayne A.
    Smith, Langan S.
    Nace, James
    Malkani, Arthur L.
    Jaggard, Charles E.
    Kolisek, Frank R.
    Delanois, Ronald E.
    ARTHROPLASTY TODAY, 2021, 11 : 140 - 145
  • [34] Cementless Total Hip Arthroplasty With Alumina-on-Highly Cross-Linked Polyethylene Bearing in Young Patients With Femoral Head Osteonecrosis
    Kim, Young-Hoo
    Choi, Yoowang
    Kim, Jun-Shik
    JOURNAL OF ARTHROPLASTY, 2011, 26 (02) : 218 - 223
  • [35] Long-Term Survivorship of Total Hip Arthroplasty with Highly Cross-Linked Polyethylene for Osteonecrosis
    Hart, Adam
    Janz, Viktor
    Trousdale, Robert T.
    Sierra, Rafael J.
    Berry, Daniel J.
    Abdel, Matthew P.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2019, 101 (17) : 1563 - 1568
  • [36] Thirteen-year results of cementless total hip arthroplasty with zirconia heads on highly cross-linked polyethylene
    Naito, Yohei
    Hasegawa, Masahiro
    Tone, Shine
    Wakabayashi, Hiroki
    Sudo, Akihiro
    MODERN RHEUMATOLOGY, 2021, 31 (05) : 1045 - 1049
  • [37] Highly cross-linked polyethylene is the new 'gold standard' bearing material for total hip arthroplasty
    Medley, John B.
    BIOSURFACE AND BIOTRIBOLOGY, 2021, 7 (02) : 53 - 59
  • [38] A Double-Blind, Prospective, Randomized Controlled Trial Comparing Highly Cross-Linked and Conventional Polyethylene in Primary Total Hip Arthroplasty
    Calvert, George T.
    Devane, Peter A.
    Fielden, Jan
    Adams, Kathryn
    Horne, J. Geoffrey
    JOURNAL OF ARTHROPLASTY, 2009, 24 (04) : 505 - 510
  • [39] Intermediate Results of Simultaneous Alumina-on-Alumina Bearing and Alumina-on-Highly Cross-Linked Polyethylene Bearing Total Hip Arthroplasties
    Kim, Young-Hoo
    Kim, Jun-Shik
    Choi, Yoo-Wang
    Kwon, Oh-Ryong
    JOURNAL OF ARTHROPLASTY, 2009, 24 (06) : 885 - 891
  • [40] Large Femoral Heads in Total Hip Arthroplasty With Vitamin E Highly Cross-Linked Polyethylene: Head Penetration Rates Compared to Highly Cross-Linked Polyethylene
    Nielson, Trent
    Owens, Garrett
    Miller, Brandon
    Meneghini, Ethan
    Deckard, Evan R.
    Meneghini, R. Michael
    JOURNAL OF ARTHROPLASTY, 2022, 37 (07) : S685 - S691