Total hip replacement using a highly cross-linked polyethylene liner in Asians with small acetabulum

被引:6
|
作者
Chua, Weiliang [1 ]
Roy, Shuvendu [1 ]
Sng, Jonathan [1 ]
Liang, Shen [1 ]
Das De, Shamal [1 ]
机构
[1] Natl Univ Singapore Hosp, Singapore 119074, Singapore
来源
JOURNAL OF ORTHOPAEDIC SURGERY | 2014年 / 22卷 / 03期
关键词
arthroplasty; replacement; hip; osteolysis; polyethylene; MOLECULAR-WEIGHT POLYETHYLENE; FEMORAL-HEAD; FOLLOW-UP; WEAR; ARTHROPLASTY; OSTEOLYSIS; ASSOCIATION; COMPONENTS; REVISION; QUALITY;
D O I
10.1177/230949901402200315
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose. To evaluate the medium-term outcomes of total hip replacement (THR) using a thin highly cross-linked polyethylene (HXLPE) liner in an Asian population. Methods. Medical records of 20 men and 44 women aged 26 to 80 (mean, 59) years who underwent 80 THRs using a thin HXLPE liner by a single surgeon were reviewed. Indications for THR included dysplasia (n= 26), avascular necrosis (n= 26), osteoarthritis (n= 22), rheumatoid arthritis (n= 4), and ankylosing spondylitis (n= 2). The surgical technique, implant used, and rehabilitation protocol were standardised. Radiographs were evaluated for cup migration and peri-implant radiolucency. Femoral head penetration was assessed at day 1 and last follow-up using the Kang modification of the Dorr and Wan method and the PowerPoint method. Results. After a mean follow-up of 7.5 (range, 5.0-11.9) years, no patient had undergone acetabular revision. Two hips were revised for the femoral stem. Femoral head penetration did not correlate with sex, age at surgery, hip pathology, acetabular inclination angle, cup size, or liner thickness. The maximum femoral head penetration was 0.09 mm/year, which was below the osteolysis threshold of 0.1 mm/year. The mean +/- standard deviation femoral head penetration was 0.29 +/- 0.12 mm (or 0.04 +/- 0.02 mm/year) by the PowerPoint method and 0.17 +/- 0.22 mm (or 0.02 +/- 0.03 mm/year) by the Kang modification of the Dorr and Wan method. Femoral head penetration correlated with the number of years of follow-up (p= 0.012). Conclusion. The use of a thin HXLPE liner in primary THR for patients with small acetabulum achieved good outcomes after a mean of 7.5 years.
引用
收藏
页码:342 / 346
页数:5
相关论文
共 50 条
  • [1] Wear of a highly cross-linked polyethylene liner: a preliminary RSA study
    Campbell, David
    Mercer, Graham
    Nilsson, Kjell-Gunnar
    Wells, Vanessa
    Field, John R.
    Callary, Stuart A.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2010, 20 (01): : 23 - 27
  • [2] Influence of liner offset and locking mechanism on fatigue durability in highly cross-linked polyethylene total hip prostheses
    Kamada, Kosuke
    Takahashi, Yasuhito
    Tateiwa, Toshiyuki
    Shishido, Takaaki
    Masaoka, Toshinori
    Pezzotti, Giuseppe
    Yamamoto, Kengo
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2020, 108 (05) : 1993 - 2004
  • [3] Midterm Results of Primary Total Hip Arthroplasty Using Highly Cross-Linked Polyethylene
    Lee, Ji-Ho
    Lee, Byung Woo
    Lee, Byoung-Joo
    Kim, Shin-Yoon
    JOURNAL OF ARTHROPLASTY, 2011, 26 (07): : 1014 - 1019
  • [4] Hip Resurfacing Using Highly Cross-linked Polyethylene: Prospective Study Results at 8.5 Years
    Pritchett, James W.
    JOURNAL OF ARTHROPLASTY, 2016, 31 (10): : 2203 - 2208
  • [5] Hip resurfacing with a highly cross-linked polyethylene acetabular liner and a titanium nitride-coated femoral component
    Pritchett, James W.
    HIP INTERNATIONAL, 2018, 28 (04) : 422 - 428
  • [6] Durability of Highly Cross-Linked Polyethylene in Total Hip and Total Knee Arthroplasty
    Dion, Neil T.
    Bragdon, Charles
    Muratoglu, Orhun
    Freiberg, Andrew A.
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 2015, 46 (03) : 321 - +
  • [7] Wear Kinetics of Highly Cross-Linked and Conventional Polyethylene Are Similar at Medium-term Follow-Up After Primary Total Hip Arthroplasty
    Mayer, Constantin
    Rommelmann, Moritz
    Behringer, Michael
    Jaeger, Marcus
    Krauspe, Ruediger
    Zilkens, Christoph
    JOURNAL OF ARTHROPLASTY, 2018, 33 (08): : 2671 - 2676
  • [8] Total hip arthroplasty using highly cross-linked polyethylene in patients aged 50 years and younger
    Roedel, G. G.
    Kildow, B. J.
    Sveom, D. S.
    Garvin, K. L.
    BONE & JOINT JOURNAL, 2021, 103B (07): : 78 - 83
  • [9] Highly Cross-Linked Polyethylene in Total Hip and Knee Replacement: Spatial Distribution of Molecular Orientation and Shape Recovery Behavior
    Takahashi, Yasuhito
    Masaoka, Toshinori
    Pezzotti, Giuseppe
    Shishido, Takaaki
    Tateiwa, Toshiyuki
    Kubo, Kosuke
    Yamamoto, Kengo
    BIOMED RESEARCH INTERNATIONAL, 2014, 2014
  • [10] The Wear Rate of Highly Cross-Linked Polyethylene in Total Hip Replacement Is Not Increased by Large Articulations A Randomized Controlled Trial
    Howie, Donald W.
    Holubowycz, Oksana T.
    Callary, Stuart A.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2016, 98 (21): : 1786 - 1793