Total hip replacement using a highly cross-linked polyethylene liner in Asians with small acetabulum

被引:6
作者
Chua, Weiliang [1 ]
Roy, Shuvendu [1 ]
Sng, Jonathan [1 ]
Liang, Shen [1 ]
Das De, Shamal [1 ]
机构
[1] Natl Univ Singapore Hosp, Singapore 119074, Singapore
关键词
arthroplasty; replacement; hip; osteolysis; polyethylene; MOLECULAR-WEIGHT POLYETHYLENE; FEMORAL-HEAD; FOLLOW-UP; WEAR; ARTHROPLASTY; OSTEOLYSIS; ASSOCIATION; COMPONENTS; REVISION; QUALITY;
D O I
10.1177/230949901402200315
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose. To evaluate the medium-term outcomes of total hip replacement (THR) using a thin highly cross-linked polyethylene (HXLPE) liner in an Asian population. Methods. Medical records of 20 men and 44 women aged 26 to 80 (mean, 59) years who underwent 80 THRs using a thin HXLPE liner by a single surgeon were reviewed. Indications for THR included dysplasia (n= 26), avascular necrosis (n= 26), osteoarthritis (n= 22), rheumatoid arthritis (n= 4), and ankylosing spondylitis (n= 2). The surgical technique, implant used, and rehabilitation protocol were standardised. Radiographs were evaluated for cup migration and peri-implant radiolucency. Femoral head penetration was assessed at day 1 and last follow-up using the Kang modification of the Dorr and Wan method and the PowerPoint method. Results. After a mean follow-up of 7.5 (range, 5.0-11.9) years, no patient had undergone acetabular revision. Two hips were revised for the femoral stem. Femoral head penetration did not correlate with sex, age at surgery, hip pathology, acetabular inclination angle, cup size, or liner thickness. The maximum femoral head penetration was 0.09 mm/year, which was below the osteolysis threshold of 0.1 mm/year. The mean +/- standard deviation femoral head penetration was 0.29 +/- 0.12 mm (or 0.04 +/- 0.02 mm/year) by the PowerPoint method and 0.17 +/- 0.22 mm (or 0.02 +/- 0.03 mm/year) by the Kang modification of the Dorr and Wan method. Femoral head penetration correlated with the number of years of follow-up (p= 0.012). Conclusion. The use of a thin HXLPE liner in primary THR for patients with small acetabulum achieved good outcomes after a mean of 7.5 years.
引用
收藏
页码:342 / 346
页数:5
相关论文
共 27 条
[1]  
Baker DA, 1999, J BIOMED MATER RES, V46, P573, DOI 10.1002/(SICI)1097-4636(19990915)46:4<573::AID-JBM16>3.0.CO
[2]  
2-A
[3]   The 2012 John Charnley Award: Clinical Multicenter Studies of the Wear Performance of Highly Crosslinked Remelted Polyethylene in THA [J].
Bragdon, Charles R. ;
Doerner, Michael ;
Martell, John ;
Jarrett, Bryan ;
Palm, Henrik ;
Malchau, Henrik .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2013, 471 (02) :393-402
[4]  
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
[5]  
DORR LD, 1995, CLIN ORTHOP RELAT R, P191
[6]   STRUCTURAL AND CELLULAR ASSESSMENT OF BONE QUALITY OF PROXIMAL FEMUR [J].
DORR, LD ;
FAUGERE, MC ;
MACKEL, AM ;
GRUEN, TA ;
BOGNAR, B ;
MALLUCHE, HH .
BONE, 1993, 14 (03) :231-242
[7]   Characterization of long-term femoral-head-penetration rates - Association with and prediction of osteolysis [J].
Dowd, JE ;
Sychterz, CJ ;
Young, AM ;
Engh, CA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (08) :1102-1107
[8]   A literature review of the association between wear rate and osteolysis in total hip arthroplasty [J].
Dumbleton, JH ;
Manley, MT ;
Edidin, AA .
JOURNAL OF ARTHROPLASTY, 2002, 17 (05) :649-661
[9]   A Prospective, Randomized Study of Cross-Linked and Non-Cross-Linked Polyethylene for Total Hip Arthroplasty at 10-Year Follow-Up [J].
Engh, Charles A., Jr. ;
Hopper, Robert H., Jr. ;
Huynh, Cathy ;
Ho, Henry ;
Sritulanondha, Supatra ;
Engh, Charles A., Sr. .
JOURNAL OF ARTHROPLASTY, 2012, 27 (08) :2-7
[10]  
GRUEN TA, 1979, CLIN ORTHOP RELAT R, P17