Simultaneous electrochemical determination of uric acid, dopamine, and ascorbic acid at single-walled carbon nanohorn modified glassy carbon electrode

被引:219
|
作者
Zhu, Shuyun [1 ,2 ]
Li, Haijuan [1 ,2 ]
Niu, Wenxin [1 ,2 ]
Xu, Guobao [1 ]
机构
[1] Chinese Acad Sci, Changchun Inst Appl Chem, State Key Lab Electroanalyt Chem, Changchun 130022, Jilin, Peoples R China
[2] Chinese Acad Sci, Grad Univ, Beijing 100864, Peoples R China
基金
中国国家自然科学基金;
关键词
Single-walled carbon nanohorn; Simultaneous determination; Uric acid; Dopamine; Ascorbic acid; VOLTAMMETRIC DETECTION; BIOSENSING PROPERTIES; HYBRID FILM; DIAMOND; NEUROTRANSMITTERS; ADSORPTION; SENSORS;
D O I
10.1016/j.bios.2009.08.022
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Single-walled carbon nanohorn modified glassy carbon electrode (SWCNH-modified GCE) was first employed for the simultaneous determination of uric acid (UA), dopamine (DA), and ascorbic acid (AA). The SWCNH-modified GCE displayed excellent electrochemical catalytic activities. The oxidation overpotentials of UA, DA, and AA decrease significantly and their oxidation peak currents increase dramatically at SWCNH-modified GCE. Linear sweep voltammetry (LSV) was used for the simultaneous determination of UA, DA, and AA in their ternary mixture. The peak separations between UA and DA, and DA and AA are large up to 152 mV and 221 mV, respectively. The calibration curves for UA, DA, and AA were obtained in the range of 0.06-10 mu M, 0.2-3.8 mu M, and 30-400 mu M, respectively. The detection limits (S/N = 3) were 20 nM, 60 nM, and 5 mu M for UA, DA, and AA, respectively. The proposed method improved sensitivity for the determination of UA by more than one order of magnitude. The present method was applied to the determination of UA, DA, and AA in urine sample by using standard adding method and the results were satisfactory. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:940 / 943
页数:4
相关论文
共 50 条
  • [31] Electrochemical Determination of Acetaminophen Using a Hydrophilic Single-Walled Carbon Nanohorn Modified Glassy Carbon Electrode
    Weng, Yu-Ching
    Yang, Ting-Yu
    Liu, The-Wang
    Su, Chi-Jung
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2023, 170 (09)
  • [32] Simultaneous electrochemical determination of dopamine, uric acid and ascorbic acid using palladium nanoparticle-loaded carbon nanofibers modified electrode
    Huang, Jianshe
    Liu, Yang
    Hou, Haoqing
    You, Tianyan
    BIOSENSORS & BIOELECTRONICS, 2008, 24 (04) : 632 - 637
  • [33] Simultaneous Determination of Dopamine, Serotonin and Ascorbic Acid at a Glassy Carbon Electrode Modified with Carbon-Spheres
    Zhou, Jianqing
    Sheng, Meili
    Jiang, Xueyue
    Wu, Guozhi
    Gao, Feng
    SENSORS, 2013, 13 (10): : 14029 - 14040
  • [34] Electrochemical characterization of poly(eriochrome black T) modified glassy carbon electrode and its application to simultaneous determination of dopamine, ascorbic acid and uric acid
    Yao, Hong
    Sun, Yuanyuan
    Lin, Xinhua
    Tang, Yuhai
    Huang, Liying
    ELECTROCHIMICA ACTA, 2007, 52 (20) : 6165 - 6171
  • [35] Simultaneous Electrochemical Determination of Ascorbic Acid, Dopamine and Uric Acid Based on Reduced Graphene Oxide-Ag/PANI Modified Glassy Carbon Electrode
    Guo Zhuo
    Luo Xianke
    Li Yahui
    Li Dongdi
    Zhao Qinai
    Li Mengmeng
    Ma Chi
    Zhao Yanting
    CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2017, 33 (03) : 507 - 512
  • [36] Glassy carbon electrode modified with poly(dibromofluorescein) for the selective determination of dopamine and uric acid in the presence of ascorbic acid
    Yan Wang
    Yan Xiao
    Microchimica Acta, 2012, 178 : 123 - 130
  • [37] Selective Determination of Dopamine, Ascorbic Acid and Uric Acid at SDS-MWCNTs Modified Glassy Carbon Electrode
    Zhang, Jian
    Zhu, Zhixin
    Zhu, Jianling
    Li, Kechang
    Hua, Shucheng
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (03): : 1264 - 1272
  • [38] Simultaneous determination of dopamine, ascorbic acid, and uric acid using carbon ionic liquid electrode
    Safavi, Afsaneh
    Maleki, Norouz
    Moradlou, Omran
    Tajabadi, Fariba
    ANALYTICAL BIOCHEMISTRY, 2006, 359 (02) : 224 - 229
  • [39] Fabrication of poly(orthanilic acid)-multiwalled carbon nanotubes composite film-modified glassy carbon electrode and its use for the simultaneous determination of uric acid and dopamine in the presence of ascorbic acid
    Zhang, Lei
    Shi, Zhige
    Lang, Qiuhua
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2011, 15 (04) : 801 - 809
  • [40] Glassy carbon electrode modified with poly(dibromofluorescein) for the selective determination of dopamine and uric acid in the presence of ascorbic acid
    Wang, Yan
    Xiao, Yan
    MICROCHIMICA ACTA, 2012, 178 (1-2) : 123 - 130