Background and Purpose. In contrast to digital subtraction angiography (DSAdia), computed tomography angiography (CTA) provides exact delineation of the perfused lumen in the axial plane, thus allowing luminal (CTAdia) as well as cross-sectional area (CTAarea) internal carotid artery stenosis (ICAS) assessment. The purposes of the present study were to correlate CTAdia and CTAarea with DSAdia and to assess the inter-observer variabilities of both CTA techniques. Methods. In a retrospective analysis, CTA images were reviewed by two observers and ICAS was assessed according to North American Symptomatic Carotid Endarterectomy Trial applying CTAdia and CTAarea. DSAdia was assessed by a third observer. Results. Based on 54 consecutive patients (40 males [74.1%] and 14 females [25.9%]; median age 73.3 years), ICAS percentages of CTAdia and CTAarea revealed significant correlations with DSAdia (r = 0.79-0.87, all P <.001) with median differences in the range of +8% to -6%. Inter-observer agreement was moderate for CTAdia (kappa = 0.60) and excellent for CTAarea (kappa = 0.86). Sensitivity of CTAarea for the detection of ICAS > 70% was 100% for both observers, corresponding results for CTAdia were 97.1% and 71.4%, respectively, using DSAdia as the gold standard. Conclusion. CTAarea assessment of ICAS correlates well with the results of DSAdia and provides an excellent sensitivity for the detection of ICAS > 70% with superior inter-observer agreement compared to CTAdia.
引用
收藏
页码:219 / 226
页数:8
相关论文
共 19 条
[11]   PROGNOSTIC VALUE AND REPRODUCIBILITY OF MEASUREMENTS OF CAROTID STENOSIS - A COMPARISON OF 3 METHODS ON 1001 ANGIOGRAMS [J].
ROTHWELL, PM ;
GIBSON, RJ ;
SLATTERY, J ;
WARLOW, CP .
STROKE, 1994, 25 (12) :2440-2444
[12]   Critical appraisal of the design and reporting of studies of imaging and measurement of carotid stenosis [J].
Rothwell, PM ;
Pendlebury, ST ;
Wardlaw, J ;
Warlow, CP .
STROKE, 2000, 31 (06) :1444-1450
[13]  
TAYLOR DW, 1991, NEW ENGL J MED, V325, P445
[14]  
VANNINEN R, 1994, AM J NEURORADIOL, V15, P1635
[15]   ENDARTERECTOMY FOR ASYMPTOMATIC CAROTID-ARTERY STENOSIS [J].
WALKER, MD ;
MARLER, JR ;
GOLDSTEIN, M ;
GRADY, PA ;
TOOLE, JF ;
BAKER, WH ;
CASTALDO, JE ;
CHAMBLESS, LE ;
MOORE, WS ;
ROBERTSON, JT ;
YOUNG, B ;
HOWARD, VJ ;
PURVIS, S ;
VERNON, DD ;
NEEDHAM, K ;
BECK, P ;
DOZIER, M ;
LEFKOWITZ, DS ;
HOWARD, G ;
CROUSE, JR ;
HERRINGTON, DM ;
FURBERG, CD ;
ESSICK, K ;
HICKS, RM ;
NELSON, JJ ;
BALL, W ;
BLAND, E ;
CONDON, S ;
ELLIOTT, T ;
GRIZZLE, JE ;
HAYES, D ;
HENLEY, S ;
JOHNSON, J ;
LOCKLEAR, J ;
MISCH, MS ;
PATON, CC ;
SCHWARTZ, S ;
WALKER, C ;
WILLIAMS, OD ;
EASTON, JD ;
GOLDSTONE, J ;
HALLENBECK, JM ;
HOFF, JT ;
KARP, HR ;
KRONMAL, RA ;
BROTT, TG ;
TOMSICK, TA ;
BRODERICK, J ;
SAUERBECK, L ;
BLUM, C .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1995, 273 (18) :1421-1428
[16]   MRC-EUROPEAN-CAROTID-SURGERY-TRIAL - INTERIM RESULTS FOR SYMPTOMATIC PATIENTS WITH SEVERE (70-99-PERCENT) OR WITH MILD (0-29-PERCENT) CAROTID STENOSIS [J].
WARLOW, C .
LANCET, 1991, 337 (8752) :1235-1243
[17]   Neurologic complications of cerebral angiography: Prospective analysis of 2,899 procedures and review of the literature [J].
Willinsky, RA ;
Taylor, SM ;
terBrugge, K ;
Farb, RI ;
Tomlinson, G ;
Montanera, W .
RADIOLOGY, 2003, 227 (02) :522-528
[18]   Carotid stenosis degree in CT angiography:: assessment based on luminal area versus luminal diameter measurements [J].
Zhang, ZS ;
Berg, M ;
Ikonen, A ;
Könönen, M ;
Kälviäinen, R ;
Manninen, H ;
Vanninen, R .
EUROPEAN RADIOLOGY, 2005, 15 (11) :2359-2365
[19]   Carotid artery stenosis: reproducibility of automated 3D CT angiography analysis method [J].
Zhang, ZS ;
Berg, MH ;
Ikonen, AEJ ;
Vanninen, RL ;
Manninen, HI .
EUROPEAN RADIOLOGY, 2004, 14 (04) :665-672