Performance Analysis of Variable Mode Adsorption Chiller at Different Recooling Water Temperatures

被引:4
作者
Alsarayreh, Ahmad A. [1 ]
Al-Maaitah, Ayman [2 ]
Attarakih, Menwer [3 ]
Bart, Hans-Joerg [4 ]
机构
[1] Precision Ind, POB 37448, Dubai, U Arab Emirates
[2] Wahaj Investment LLC, 24B St,Comm 365,Ind 2,POB 37448, Dubai, U Arab Emirates
[3] Univ Jordan, Dept Chem Engn, Queen Rania St, Amman 11942, Jordan
[4] TU Kaiserslautern, Therm Verfahrenstech, D-67653 Kaiserslautern, Germany
关键词
adsorption; zeolite; SAPO-34; adsorption cooling; mass recovery; variable mode; MASS RECOVERY; HEAT-PUMP;
D O I
10.3390/en14133871
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Adsorption cooling can recover waste heat at low temperature levels, thereby saving energy and reducing greenhouse gas emissions. An air-cooled adsorption cooling system reduces water consumption and the technical problems associated with wet-cooling systems; however, it is difficult to maintain a constant recooling water temperature using such a system. To overcome this limitation, a variable mode adsorption chiller concept was introduced and investigated in this study. A prototype adsorption chiller was designed and tested experimentally and numerically using the lumped model. Experimental and numerical results showed good agreement and a similar trend. The adsorbent pairs investigated in this chiller consisted of silicoaluminophosphate (SAPO-34)/water. The experimental isotherm data were fitted to the Dubinin-Astakhov (D-A), Freundlich, Hill, and Sun and Chakraborty (S-C) models. The fitted data exhibited satisfactory agreement with the experimental data except with the Freundlich model. In addition, the adsorption kinetics parameters were calculated using a linear driving force model that was fitted to the experimental data with high correlation coefficients. The results show that the kinetics of the adsorption parameters were dependent on the partial pressure ratio. Four cooling cycle modes were investigated: single stage mode and mass recovery modes with duration times of 25%, 50%, and 75% of the cooling cycle time (denoted as short, medium, and long mass recovery, respectively). The cycle time was optimized based on the maximum cooling capacity. The single stage, short mass recovery, and medium mass recovery modes were found to be the optimum modes at lower (<35 degrees C), medium (35-44 degrees C), and high (>44 degrees C) recooling temperatures. Notably, the recooling water temperature profile is very important for assessing and optimizing the suitable working mode.
引用
收藏
页数:26
相关论文
共 33 条
[1]   Experimental investigation of mass recovery adsorption refrigeration cycle [J].
Akahira, A ;
Alarn, KCA ;
Hamamoto, Y ;
Akisawa, A ;
Kashiwagi, T .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (04) :565-572
[2]  
Al-Maaitah A.A., 2017, INT J CURR ENG TECHN, V7, P43
[3]  
Al-Maaitah A.A.S., 2013, U.S. Patent, Patent No. [8,479,529, 8479529]
[4]   Experimental study of a low temperature heat driven re-heat two-stage adsorption chiller [J].
Alam, K. C. A. ;
Khan, M. Z. I. ;
Uyun, A. S. ;
Hamamoto, Y. ;
Akisawa, A. ;
Kashiwagi, T. .
APPLIED THERMAL ENGINEERING, 2007, 27 (10) :1686-1692
[5]  
Alsarayreh A., 2013, JORD P 1 INT C EXH A
[6]  
Alsarayreh A.A., 2020, GCC Patent Office, Patent No. 48423
[7]   Experimental study on solar-powered adsorption refrigeration cycle with activated alumina and activated carbon as adsorbent [J].
Ambarita, Himsar ;
Kawai, Hideki .
CASE STUDIES IN THERMAL ENGINEERING, 2016, 7 :36-46
[8]  
Baiju V., 2012, P INT C MECH NAN CRY, P223
[9]  
Chan KC, 2014, PROCEEDINGS OF THE ASME 8TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, 2014, VOL 2
[10]   Adsorption-desorption characteristics of water on silico-alumino-phosphate-34 molecular sieve for cooling and air conditioning [J].
Chen, H. J. ;
Cui, Q. ;
Li, Q. G. ;
Zheng, K. ;
Yao, H. Q. .
JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2013, 5 (05)