A tibial-based coordinate system for three-dimensional data

被引:15
作者
Fitzpatrick, Clare [1 ]
FitzPatnick, David
Auger, Daniel
Lee, Jordan
机构
[1] Univ Coll Dublin, Sch Elect Elect & Mech Engn, Dublin 4, Ireland
[2] DePuy Orthopaed Inc, Warsaw, IN USA
关键词
tibial coordinate frame; 3D data; axis variation;
D O I
10.1016/j.knee.2006.11.001
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
An accurate and repeatable tibial measurement system will aid in the definition of tibial geometry and improving tibial prosthesis design. Unlike in the femur, there is no standardized method for constructing a tibial coordinate frame. Most tibial measurements are given relative to femoral axes or the coordinate frame of the CT/MRI scanner or radiograph machine. The objective of this study was to establish an independent tibial coordinate frame. Data consisted of CT scans from 34 subjects. The tibial anatomical axis was chosen as the axial axis. The anteroposterior (AP) axis was selected to be parallel to the lateral surface of the tibial shaft and orthogonal to the anatomical axis and from this the mediolateral axis could be derived. The selected AP axis was compared with the surgical tibial AP axis by measuring their variability relative to a common axis, the posterior tibial condylar line (PTCL). The mean angle between the selected AP axis and the perpendicular to the PTCL was measured as -4.07 degrees, standard deviation of 4.28 degrees. The mean angle between the surgical AP axis and the perpendicular to the PTCL was measured as - 18.56 degrees, standard deviation of 4.66 degrees. There was no significant difference in the variance of the two sets of measurements (p=0.63). Variability of the selected AP axis was even smaller (standard deviation of 2.74 degrees) when measured independently from the PTCL reference axis, by aligning virtual resection profiles. Anatomically, the selected AP axis was almost perpendicular to the posterior tibial condylar axis. This coordinate system can aid in gathering consistent and repeatable anthropometric data that can be used to improve tibial implant design and could also, in combination with CT/MR imaged-based computer assisted surgery, be used as a guideline for tibial component positioning in TKR. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:133 / 137
页数:5
相关论文
共 25 条
[1]   Variability of extraarticular tibial rotation references for total knee arthroplasty [J].
Akagi, M ;
Mori, S ;
Nishimura, S ;
Nishimura, A ;
Asano, T ;
Hamanishi, C .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (436) :172-176
[2]   An anteroposterior axis of the tibia for total knee arthroplasty [J].
Akagi, M ;
Oh, M ;
Nonaka, T ;
Tsujimoto, H ;
Asano, T ;
Hamanishi, C .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (420) :213-219
[3]   The use of functional analysis in evaluating knee kinematics [J].
Andriacchi, TP ;
Dyrby, CO ;
Johnson, TS .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (410) :44-53
[4]   A METHOD FOR REGISTRATION OF 3-D SHAPES [J].
BESL, PJ ;
MCKAY, ND .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1992, 14 (02) :239-256
[5]   Using the transepicondylar axis to define the sagittal morphology of the distal part of the femur [J].
Blaha, JD ;
Mancinelli, CA ;
Simons, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A :48-55
[6]  
BLOEBAUM RD, 1994, CLIN ORTHOP RELAT R, P2
[7]   A new approach of designing the tibial baseplate of total knee prostheses [J].
Cheng, CK ;
Lung, CY ;
Lee, YM ;
Huang, CH .
CLINICAL BIOMECHANICS, 1999, 14 (02) :112-117
[8]  
Çubuk SM, 2000, CLIN ANAT, V13, P199, DOI 10.1002/(SICI)1098-2353(2000)13:3<199::AID-CA7>3.0.CO
[9]  
2-O
[10]  
ERKMAN MJ, 1974, BIOMED ENG, V9, P14