Patellar Tracking in Total Knee Arthroplasty-Influence on Clinical and Functional Outcome

被引:14
作者
Dahlmann, Sebastian [1 ]
Ziegeler, Katharina [1 ]
Mau-Moeller, Anett [2 ,3 ]
Mittelmeier, Wolfram [2 ,3 ]
Bergschmidt, Philipp [2 ,3 ,4 ]
机构
[1] Charite Univ Med Berlin, Dept Radiol, Luisenstr 7, D-10117 Berlin, Germany
[2] Univ Med Rostock, Orthopaed Clin, Doberaner Str 142, D-18057 Rostock, Germany
[3] Univ Med Rostock, Outpatient Dept, Doberaner Str 142, D-18057 Rostock, Germany
[4] Sudstadt Hosp Rostock, Dept Orthopaed Surg Trauma Surg & Hand Surg, Sudring 81, D-18059 Rostock, Germany
关键词
total knee arthroplasty; anterior knee pain; patellar tracking; POSITION; PAIN; TILT;
D O I
10.3390/diagnostics12051082
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Anterior knee pain is a common problem after primary total knee arthroplasty (TKA). The aim of this study was to find parameters in patellar positioning which influence the clinical and functional outcome after TKA. Included were 59 patients who underwent TKA, of which three patients were treated bilaterally (n = 62 included knees). In a periodical follow-up of up to 5 years, each patient had to answer three questionnaires (HSS, WOMAC, SF-36) and underwent three radiographies of the knee (including merchant view) and a clinical examination, including Range Of Motion (ROM). All radiographs were evaluated by a single observer blinded to clinical data, who collected multiple parameters of sagittal and axial patellar alignment including newly developed methods for measuring patellar shift and tilt. Depending on the measurement results, three groups were built for each parameter and the influence on the outcome was determined. A lateral patellar tilt of more than 4 degrees resulted in lower scores for both the HSS and WOMAC. The rarely investigated patellar facet angle showed a significantly inferior clinical and functional outcome in late follow-up of >24 months if lower than 142 degrees, possibly due to progressive osteosclerotic changes of the patella caused by increased contact stress with corresponding patellar morphology. No significant difference was found for all other parameters. The newly developed method for measuring patellar shift has proven to be a valuable and easy instrument in the postoperative setting.
引用
收藏
页数:12
相关论文
共 35 条
[1]   Patellar Resurfacing versus Nonresurfacing with Patellaplasty in Total Knee Arthroplasty [J].
Agarwala, Sanjay ;
Shetty, Vivek ;
Karumuri, Lnvsl Kishore ;
Vijayvargiya, Mayank .
INDIAN JOURNAL OF ORTHOPAEDICS, 2018, 52 (04) :393-398
[2]   CONTROLLING THE FALSE DISCOVERY RATE - A PRACTICAL AND POWERFUL APPROACH TO MULTIPLE TESTING [J].
BENJAMINI, Y ;
HOCHBERG, Y .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES B-STATISTICAL METHODOLOGY, 1995, 57 (01) :289-300
[3]   Prospective comparative clinical study of ceramic and metallic femoral components for total knee arthroplasty over a five-year follow-up period [J].
Bergschmidt, Philipp ;
Ellenrieder, Martin ;
Bader, Rainer ;
Kluess, Daniel ;
Finze, Susanne ;
Schwemmer, Benjamin ;
Mittelmeier, Wolfram .
KNEE, 2016, 23 (05) :871-876
[4]  
BINDELGLASS DF, 1993, CLIN ORTHOP RELAT R, P103
[5]   NEW METHOD OF MEASURING PATELLAR HEIGHT [J].
BLACKBURNE, JS ;
PEEL, TE .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1977, 59 (02) :241-242
[6]  
CATON J, 1982, REV CHIR ORTHOP, V68, P317
[7]   Patellar tilt and thickness do not influence postoperative flexion in a high-flex design total knee arthroplasty [J].
Dhollander, Aad Alfons Maria ;
Bassens, David ;
Victor, Jan ;
Verdonk, Peter .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (12) :2817-2822
[8]   Different Factors Conduct Anterior Knee Pain Following Primary Total Knee Arthroplasty: A Systematic Review and Meta-Analysis [J].
Duan, Guman ;
Liu, Chang ;
Lin, Weiwei ;
Shao, Jiashen ;
Fu, Kunpeng ;
Niu, Yingzhen ;
Wang, Fei .
JOURNAL OF ARTHROPLASTY, 2018, 33 (06) :1962-+
[9]  
Fath R., 2018, DTSCH ARZTEBL INT, V115, pA
[10]  
GOMES LSM, 1988, CLIN ORTHOP RELAT R, P72