False-positive reactivity of anti-human leukocyte antigen antibodies detected using the single-antigen bead assay

被引:8
作者
Kim, Boyeon [1 ,2 ]
Kim, Sinyoung [1 ]
Park, Younhee [1 ]
Kim, Hyon-Suk [1 ]
机构
[1] Yonsei Univ, Coll Med, Severance Hosp, Dept Lab Med, Seoul 03722, South Korea
[2] Yonsei Univ, Coll Med, Gangnam Severance Hosp, Dept Lab Med, Seoul 06273, South Korea
关键词
Human leukocyte antigen; Transplantation; Single-antigen bead assay; Antibodies; Allele frequency; KIDNEY-TRANSPLANT; CROSS-MATCH; SENSITIZATION;
D O I
10.1016/j.humimm.2021.03.002
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
The single-antigen bead assay (SABA) demonstrates high sensitivity and specificity for detecting anti-human leukocyte antigen (HLA) antibodies. However, SABA may produce false-positive results for anti-HLA antibodies. Herein, we analyzed the data of patients with complement-dependent cytotoxic crossmatch-/flow cytometric crossmatch-/SABA(+/-) results to determine false-positive results for anti-HLA antibodies. We also determined the prevalence of false-positive results by comparing false-positive data from our laboratory and national allele frequency data obtained with high-resolution HLA typing. For HLA-A, -B, -C, and -DR, a ratio of positive frequency to allele frequency of >= 3 in our laboratory was considered a false-positive result. For HLA-DQA1/DQB1 and HLA-DPA1/DPB1, we considered the positive frequency of >= 3 as a false positive result due to lack of haplotype frequency data. SABA results from 284 patients (78.0%) demonstrated false reactivity. The antibody against HLA-C*17:01 displayed the highest frequency ratio (298.3). If false-positive reactivity is suspected, results should be confirmed using different methods. If confirmation tests are unfeasible, comparing the allele frequency with the positive rate of detected anti-HLA antibodies and using a ratio >= 3 may facilitate the interpretation of SABA results. The positive rate of anti-HLA antibodies can be validated using the HLA allele frequency of the population to determine false-positive results. (C) 2021 American Society for Histocompatibility and Immunogenetics. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:409 / 413
页数:5
相关论文
共 18 条
[1]  
Althaf Mohammed Mahdi, 2017, World J Transplant, V7, P339, DOI 10.5500/wjt.v7.i6.339
[2]  
[Anonymous], ALLELE FREQUENCY DQA
[3]  
[Anonymous], ALLELE FREQUENCY DPB
[4]  
[Anonymous], ALLELE FREQUENCY DQA
[5]  
BAROCCI S, 1991, CLIN NEPHROL, V36, P12
[6]   Identification of a recurrent pattern of false-positivity by Luminex HLA MHC class I single antigen bead testing [J].
Dean, Christina L. ;
Krummey, Scott M. ;
Gebel, Howard M. ;
Bray, Robert A. ;
Sullivan, Harold C. .
HUMAN IMMUNOLOGY, 2020, 81 (2-3) :73-78
[7]  
Downing Jonathan, 2012, Methods Mol Biol, V882, P379, DOI 10.1007/978-1-61779-842-9_22
[8]   Epitopes of human leukocyte antigen class I antibodies found in sera of normal healthy males and cord blood [J].
El-Awar, Nadim ;
Terasaki, Paul I. ;
Nguyen, Anh ;
Sasaki, Nori ;
Morales-Buenrostro, Luis E. ;
Saji, Hiroh ;
Maruya, Etsuko ;
Poli, Francesca .
HUMAN IMMUNOLOGY, 2009, 70 (10) :844-853
[9]   Influence of Test Technique on Sensitization Status of Patients on the Kidney Transplant Waiting List [J].
Gombos, P. ;
Opelz, G. ;
Scherer, S. ;
Morath, C. ;
Zeier, M. ;
Schemmer, P. ;
Suesal, C. .
AMERICAN JOURNAL OF TRANSPLANTATION, 2013, 13 (08) :2075-2082
[10]   Improved flow cytometry crossmatching in kidney transplantation [J].
Guillaume, Nicolas .
HLA, 2018, 92 (06) :375-383