Adherence to guidelines strongly improves reproducibility of brachial artery flow-mediated dilation

被引:64
作者
Greyling, Arno [1 ,2 ]
van Mil, Anke C. C. M. [1 ,3 ,4 ]
Zock, Peter L. [2 ,3 ]
Green, Daniel J. [5 ]
Ghiadoni, Lorenzo [6 ]
Thijssen, Dick H. [1 ,7 ]
机构
[1] Radboud Univ Nijmegen, Dept Physiol, Med Ctr, NL-6525 ED Nijmegen, Netherlands
[2] Unilever Res Labs, Vlaardingen, Netherlands
[3] TI Food & Nutr, Wageningen, Netherlands
[4] Maastricht Univ, Med Ctr, NL-6200 MD Maastricht, Netherlands
[5] Univ Western Australia, Sch Sports Sci Exercise & Hlth, Crawley, Australia
[6] Univ Pisa, Pisa, Italy
[7] Liverpool John Moores Univ, Res Inst Sport & Exercise Sci, Liverpool L3 5UX, Merseyside, England
关键词
Cardiovascular disease; Atherosclerosis; Endothelial function; Reproducibility; Methodology; ENDOTHELIAL FUNCTION; NONINVASIVE ASSESSMENT; DILATATION; ULTRASOUND; VASODILATION; HUMANS; VARIABILITY; DYSFUNCTION; DIAMETER; MULTICENTER;
D O I
10.1016/j.atherosclerosis.2016.03.011
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Brachial artery FMD is widely used as a non-invasive measure of endothelial function. Adherence to expert guidelines is believed to be of vital importance to obtain reproducible measurements. We conducted a systematic review of studies reporting on the reproducibility of the FMD in order to determine the relation between adherence to current expert guidelines for FMD measurement and its reproducibility. Methods: Medline-database was searched through July 2015 and 458 records were screened for FMD reproducibility studies reporting the mean difference and variance of repeated FMD measurements. An adherence score was assigned to each of the included studies based on reported adherence to published guidelines on the assessment of brachial artery FMD. A Typical Error Estimate (TEE) of the FMD was calculated for each included study. The relation between the FMD TEE and the adherence score was investigated by means of Pearson correlation coefficients and multiple linear regression analysis. Results: Twenty-seven studies involving 48 study groups and 1537 subjects were included in the analyses. The adherence score ranged from 2.4 to 9.2 (out of a maximum of 10) and was strongly and inversely correlated with FMD TEE (adjusted R-2 = 0.36, P < 0.01). Use of automated edge-detection software, continuous diameter measurement, true peak diameter for %FMD calculation, a stereostatic probe holder, and higher age emerged as factors associated with a lower FMD TEE. Conclusions: These data demonstrate that adherence to current expert consensus guidelines and applying contemporary techniques for measuring brachial artery FMD decreases its measurement error. (C) 2016 The Authors. Published by Elsevier Ireland Ltd.
引用
收藏
页码:196 / 202
页数:7
相关论文
共 44 条
  • [1] Automatic evaluation of arterial diameter variation from vascular echographic images
    Beux, F
    Carmassi, S
    Salvetti, MV
    Ghiadoni, L
    Huang, Y
    Taddei, S
    Salvetti, A
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (12) : 1621 - 1629
  • [2] Functional and Structural Alterations of Large Arteries: Methodological Issues
    Bianchini, Elisabetta
    Giannarelli, Chiara
    Bruno, Rosa Maria
    Armenia, Sabina
    Landini, Linda
    Faita, Francesco
    Gemignani, Vincenzo
    Taddei, Stefano
    Ghiadoni, Lorenzo
    [J]. CURRENT PHARMACEUTICAL DESIGN, 2013, 19 (13) : 2390 - 2400
  • [3] Importance of measuring the time course of flow-mediated dilatation in humans
    Black, Mark A.
    Cable, N. Timothy
    Thijssen, Dick H. J.
    Green, Daniel J.
    [J]. HYPERTENSION, 2008, 51 (02) : 203 - 210
  • [4] Impact of age, sex, and exercise on brachial artery flow-mediated dilatation
    Black, Mark A.
    Cable, N. Timothy
    Thijssen, Dick H. J.
    Green, Daniel J.
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2009, 297 (03): : H1109 - H1116
  • [5] Cde M. Meirelles, 2007, ARQ BRAS CARDIOL, V89, P176
  • [6] NONINVASIVE DETECTION OF ENDOTHELIAL DYSFUNCTION IN CHILDREN AND ADULTS AT RISK OF ATHEROSCLEROSIS
    CELERMAJER, DS
    SORENSEN, KE
    GOOCH, VM
    SPIEGELHALTER, DJ
    MILLER, OI
    SULLIVAN, ID
    LLOYD, JK
    DEANFIELD, JE
    [J]. LANCET, 1992, 340 (8828) : 1111 - 1115
  • [7] Variability and reproducibility of flow-mediated dilatation in a multicentre clinical trial
    Charakida, Marietta
    de Groot, Eric
    Loukogeorgakis, Stavros P.
    Khan, Tauseef
    Luescher, Thomas
    Kastelein, John J.
    Gasser, Theo
    Deanfield, John E.
    [J]. EUROPEAN HEART JOURNAL, 2013, 34 (45) : 3501 - 3507
  • [8] Guidelines for the ultrasound assessment of endothelial-dependent flow-mediated vasodilation of the brachial artery - A report of the International Brachial Artery Reactivity Task Force
    Corretti, MC
    Anderson, TJ
    Benjamin, EJ
    Celermajer, D
    Charbonneau, F
    Creager, MA
    Deanfield, J
    Drexler, H
    Gerhard-Herman, M
    Herrington, D
    Vallance, P
    Vita, J
    Vogel, R
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (02) : 257 - 265
  • [9] New monitoring software for larger clinical application of brachial artery flow-mediated vasodilatation measurements
    Craiem, Damian
    Chironi, Gilles
    Gariepy, Jerome
    Miranda-Lacet, Jennifer
    Levenson, Jaime
    Simon, Alain
    [J]. JOURNAL OF HYPERTENSION, 2007, 25 (01) : 133 - 140
  • [10] Flow-mediated vasodilation is not impaired when HDL-cholesterol is lowered by substituting carbohydrates for monounsaturated fat
    de Roos, NM
    Bots, ML
    Siebelink, E
    Schouten, E
    Katan, MB
    [J]. BRITISH JOURNAL OF NUTRITION, 2001, 86 (02) : 181 - 188