Variation of Indoor Air Quality in a New Apartment Building by Bake-Out

被引:0
作者
Kim, S. Y. [1 ,2 ]
Kim, K. Y. [2 ]
Han, Y. S. [3 ,4 ]
Koo, J. W. [1 ,3 ,4 ]
机构
[1] Catholic Univ Korea, Grad Sch, Seoul 137701, South Korea
[2] INNOENVY Expert Community Co, Puchon 420102, South Korea
[3] Catholic Univ Korea, Dept Prevent Med, Seoul 150713, South Korea
[4] Catholic Univ Korea, Ind Med Ctr, Seoul 150713, South Korea
关键词
Bake-out; Indoor air quality; Sink effect; TVOC; Formaldehydes; BTEX; VOLATILE ORGANIC-COMPOUNDS; COMPOUNDS VOCS; FORMALDEHYDE; EMISSION;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Bake-out was executed against the newly constructed apartment buildings using two methods to find out the effect of improvement on the indoor air quality and identify the concentration changes in the indoor air by the bake-out method for 3 months after occupancy. From two methods of bake-out executed before occupying, we did not find any reduction effect on the hazardous substances in the indoor air. The concentration of the hazardous substances in the indoor air tended to increase due to the sink effect, but it turned to decrease due to enough ventilation by desorption. The extent of adsorption depends on hazardous substances, building materials and furniture. The longer the period of bake-out is noticed when the formaldehyde concentration was higher than that from the total volatile organic compounds (TVOCs) because of sink effect. Therefore TVOCs had more reducing effect on the concentration of indoor air hazardous substances than the formaldehyde. The concentration level of indoor air contamination materials could be reduced from the re-desorption of hazardous materials through a sufficient duration of ventilation although bake-out has raised the concentration level of indoor air contamination materials by the adsorption effect for a short period of time.
引用
收藏
页码:263 / 270
页数:8
相关论文
共 18 条
[1]  
BAYER CW, 1990, INT C IND AIR QUAL C
[2]  
BORAZZO J, 1993, 6 INT C IND AIR QUAL
[3]  
ETKIN DS, 1996, VOLATILE ORGANIC COM
[4]  
GIRMAN JR, 1989, PROBLEM BUILDINGS BU, P695, DOI DOI 10.1177/014362448901000305
[5]  
HODGSON M, 1994, J ALLERGY CLIN IMMUN, V94, P296, DOI 10.1016/0091-6749(94)90089-2
[6]  
Jang SK, 2007, ANAL SCI TECHNOL, V20, P453
[7]  
JANG SG, 2004, GREAT AUT M KOR SOC
[8]  
KANG DH, 2005, THESIS SEOUL NATL U
[9]   Comparison of formaldehyde emission from building finishing materials at various temperatures in under heating system; ONDOL [J].
Kim, S ;
Kim, HJ .
INDOOR AIR, 2005, 15 (05) :317-325
[10]  
LEE SJ, 2004, SURVEY INDOOR AIR QU