Catheter closure of moderate- to large-sized patent ductus arteriosus using the new Amplatzer duct occluder: Immediate and short-term results

被引:251
作者
Masura, J
Walsh, KP
Thanopoulous, B
Chan, C
Bass, J
Goussous, Y
Gavora, P
Hijazi, ZM
机构
[1] Tufts Univ, New England Med Ctr, Dept Pediat,Sch Med, Div Pediat Cardiol,Floating Hosp Children, Boston, MA 02111 USA
[2] Children Univ Hosp, Dept Cardiol, Bratislava, Slovakia
[3] Royal Liverpool Childrens Hosp, Dept Cardiol, Liverpool L7 7DG, Merseyside, England
[4] Agia Children Hosp, Dept Cardiol, Athens, Greece
[5] Glenfield Childrens Hosp, Dept Cardiol, Leicester, Leics, England
[6] Univ Minnesota, Sch Med, Dept Pediat, Div Cardiol, Minneapolis, MN 55455 USA
[7] Queen Alia Heart Inst, Amman, Jordan
关键词
D O I
10.1016/S0735-1097(98)00013-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. The aim of this study was to assess the immediate and short term results of anterograde catheter closure of a moderate-to large-sized patent ductus arteriosus (PDA) using the new self-expandable, respositionable Amplatzer duct occluder (ADO) device. Background. Transcatheter closure of a PDA using devices or coils is technically challenging and may be accompanied by a 38% incidence of residual shunts. Methods. Twenty-four patients (6 male, 18 female) underwent attempted transcatheter closure of a PDA using the ADO at a median age of 3.8 years (range 0.4 to 48) and a median weight of 15.5 kg (range 6 to 70). The mean PDA diameter at its narrowest segment was 3.7 +/- 1.5 mm. A 6F long sheath was used for delivery of the ADO. Follow up evaluation was performed with color flow mapping of the main pulmonary artery within 24 h and at 1 and 3 months after closure. Results. Twenty three of the 24 patients had successful device placement, Angiography showed that 7 patients had complete immediate closure, 14 had a trace shunt (foaming through the device with no jet), and 2 had a small residual shunt (with a jet). Within 24 h, color Doppler revealed complete closure in all patients, The unsuccessful attempt was during an initial trial with a prototype that has been modified. The median fluoroscopy time was 13.5 min (range 6.3 to 47). All patients were discharged home the next day, There were no complications, Of the 23 patients, 21 completed the 1-month follow-up, all (95% confidence interval [CI] 86% to 100%) with complete closure, and 18 of 23 patients completed the 3-month follow-up, also all (95% CI 83% to 100%) with complete closure. Conclusions. Anterograde transcatheter closure using the new ADO is an effective therapy for patients with a PDA diameter up to 6 mm, Further clinical trials are underway, (C) 1998 by the American College of Cardiology.
引用
收藏
页码:878 / 882
页数:5
相关论文
共 14 条
  • [1] [Anonymous], GER MED MON
  • [2] Transcatheter closure with single or multiple Gianturco coils of patent ductus arteriosus in infants weighing <=8kg: Retrograde versus antegrade approach
    Hijazi, ZM
    Lloyd, TR
    Beekman, RH
    Geggel, RL
    [J]. AMERICAN HEART JOURNAL, 1996, 132 (04) : 827 - 835
  • [3] RESULTS OF ANTEROGRADE TRANSCATHETER CLOSURE OF PATENT DUCTUS-ARTERIOSUS USING SINGLE OR MULTIPLE GIANTURCO COILS
    HIJAZI, ZM
    GEGGEL, RL
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1994, 74 (09) : 925 - 929
  • [4] TRANSCATHETER OCCLUSION OF THE PERSISTENTLY PATENT DUCTUS-ARTERIOSUS - 40-MONTH FOLLOW-UP AND PREVALENCE OF RESIDUAL SHUNTING
    HOSKING, MCK
    BENSON, LN
    MUSEWE, N
    DYCK, JD
    FREEDOM, RM
    [J]. CIRCULATION, 1991, 84 (06) : 2313 - 2317
  • [5] ANGIOGRAPHIC CLASSIFICATION OF THE ISOLATED, PERSISTENTLY PATENT DUCTUS-ARTERIOSUS AND IMPLICATIONS FOR PERCUTANEOUS CATHETER OCCLUSION
    KRICHENKO, A
    BENSON, LN
    BURROWS, P
    MOES, CAF
    MCLAUGHLIN, P
    FREEDOM, RM
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1989, 63 (12) : 877 - 880
  • [6] TRANSCATHETER CLOSURE OF PATENT DUCTUS-ARTERIOSUS IN PEDIATRIC-PATIENTS
    LATSON, LA
    HOFSCHIRE, PJ
    KUGLER, JD
    CHEATHAM, JP
    GUMBINER, CH
    DANFORD, DA
    [J]. JOURNAL OF PEDIATRICS, 1989, 115 (04) : 549 - 553
  • [7] TRANSCATHETER OCCLUSION OF PATENT DUCTUS-ARTERIOSUS WITH GIANTURCO COILS
    LLOYD, TR
    FEDDERLY, R
    MENDELSOHN, AM
    SANDHU, SK
    BEEKMAN, RH
    [J]. CIRCULATION, 1993, 88 (04) : 1412 - 1420
  • [8] PERCUTANEOUS CLOSURE OF THE SMALL PATENT DUCTUS-ARTERIOSUS USING OCCLUDING SPRING COILS
    MOORE, JW
    GEORGE, L
    KIRKPATRICK, SE
    MATHEWSON, JW
    SPICER, RL
    UZARK, K
    ROTHMAN, A
    CAMBIER, PA
    SLACK, MC
    KIRBY, WC
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (03) : 759 - 765
  • [9] TWO-DIMENSIONAL ECHOCARDIOGRAPHIC AND COLOR FLOW DOPPLER EVALUATION OF DUCTAL OCCLUSION WITH THE RASHKIND PROSTHESIS
    MUSEWE, NN
    BENSON, LN
    SMALLHORN, JF
    FREEDOM, RM
    [J]. CIRCULATION, 1989, 80 (06) : 1706 - 1710
  • [10] TRANSCATHETER OCCLUSION OF PATENT DUCTUS-ARTERIOSUS WITH ADJUSTABLE BUTTONED DEVICE - INITIAL CLINICAL-EXPERIENCE
    RAO, PS
    SIDERIS, EB
    HADDAD, J
    REY, C
    HAUSDORF, G
    WILSON, AD
    SMITH, PA
    CHOPRA, PS
    [J]. CIRCULATION, 1993, 88 (03) : 1119 - 1126