Impact of Contact Force Monitoring in Acute Pulmonary Vein Isolation Using an Anatomic Approach. A Randomized Study

被引:20
作者
Pedrote, Alonso [1 ]
Arana-Rueda, Eduardo [1 ]
Arce-Leon, Alvaro [1 ]
Acosta, Juan [2 ]
Gomez-Pulido, Federico [1 ]
Luis Martos-Maine, Jose [1 ]
Frutos-Lopez, Manuel [1 ]
Sanchez-Brotons, Juan [1 ]
Garcia-Riesco, Lorena [1 ]
机构
[1] Hosp Univ Virgen del Rocio, Arrhythmia Unit, Serv Cardiol, Avda Manuel Siurot S-N, Seville 41013, Spain
[2] Hosp Clin Barcelona, Dept Cardiol, Arrhythmia Sect, Barcelona, Spain
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2016年 / 39卷 / 04期
关键词
atrial fibrillation ablation; contact force monitoring; pulmonary vein gaps; radiofrequency ablation; Carto system; PAROXYSMAL ATRIAL-FIBRILLATION; RADIOFREQUENCY CATHETER ABLATION; SENSING TECHNOLOGY; RECONNECTION; MULTICENTER; TRIAL;
D O I
10.1111/pace.12811
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundThe impact of contact force (CF) monitoring in pulmonary vein (PV) isolation after a circumferential anatomic ablation (CAA) is unknown. We analyze the usefulness of CF monitoring in acute PV isolation and procedure parameters using a CAA. MethodsFifty patients with paroxysmal atrial fibrillation were randomized into CF-on (CF >10 grams; n = 25) or CF-off (CF blinded; n = 25) groups. We performed a first round of CAA with a ThermoCool((R)) SmartTouch((R)) catheter blinded to the LASSO((R)) catheter (Biosense Webster, Diamond Bar, CA, USA), with radiofrequency (RF) lesions tagged with the VisiTag Module. After the CAA, each PV was reviewed with the LASSO((R)) catheter recording the segments with gaps. ResultsAll the PVs were isolated with a CAA in 20 patients of the CF-on versus eight of the CF-off (P = 0.001). Of the 45 segments with gaps in the left PVs, 38 were from the CF-off (P = 0.0001). Of the eight segments with gaps in the right PVs, seven were from the CF-off (P = 0.06). The CF in the left PVs was higher in the CF-on (16.3 3.2 grams vs 10.5 +/- 4.3 grams; P = 0.0001) and similar in the right PVs (17.6 +/- 3.6 grams vs 15.2 +/- 5.3 grams; P = 0.08). All of the gaps were closed with additional RF LASSO((R))-guided touch-up. Procedure and fluoroscopy times were shorter in the CF-on (139 +/- 24 minutes vs 157 +/- 32 minutes and 20 +/- 6 minutes vs 24 +/- 7 minutes; both P = 0.039). At 12 months the AF recurrence was 84% CF-on versus 75% CF-off (log-rank P = 0.4). ConclusionsIn paroxysmal atrial fibrillation, a CAA guided by CF reduces PV gaps and shortens the procedure parameters at the expense of the left PVs.
引用
收藏
页码:361 / 369
页数:9
相关论文
共 50 条
  • [31] Arrhythmia-free survival and pulmonary vein reconnection patterns after second-generation cryoballoon and contact-force radiofrequency pulmonary vein isolation
    Buist, Thomas J.
    Adiyaman, Ahmet
    Smit, Jaap Jan J.
    Misier, Anand R. Ramdat
    Elvan, Arif
    [J]. CLINICAL RESEARCH IN CARDIOLOGY, 2018, 107 (06) : 498 - 506
  • [32] Pulmonary vein isolation using "contact force" ablation: The effect on dormant conduction and long-term freedom from recurrent atrial fibrillation-A prospective study
    Andrade, Jason G.
    Monir, George
    Pollak, Scott J.
    Khairy, Paul
    Dubuc, Marc
    Roy, Denis
    Talajic, Mario
    Deyell, Marc
    Rivard, Lena
    Thibault, Bernard
    Guerra, Peter G.
    Nattel, Stanley
    Macle, Laurent
    [J]. HEART RHYTHM, 2014, 11 (11) : 1919 - 1924
  • [33] Low Incidence of Esophageal Lesions After Pulmonary Vein Isolation Using Contact-Force Sensing Catheter Without Esophageal Temperature Probe
    Blockhaus, Christian
    Mueller, Patrick
    vom Dahl, Stephan
    Leonhardt, Silke
    Haeussinger, Dieter
    Gerguri, Shqipe
    Clasen, Lucas
    Schmidt, Jan
    Kurt, Muhammed
    Brinkmeyer, Christoph
    Kelm, Malte
    Shin, Dong-In
    Makimoto, Hisaki
    [J]. INTERNATIONAL HEART JOURNAL, 2017, 58 (06) : 880 - 884
  • [34] Contact force and impedance decrease during ablation depends on catheter location and orientation: insights from pulmonary vein isolation using a contact force-sensing catheter
    Sven Knecht
    Tobias Reichlin
    Nikola Pavlovic
    Beat Schaer
    Stefan Osswald
    Christian Sticherling
    Michael Kühne
    [J]. Journal of Interventional Cardiac Electrophysiology, 2015, 43 : 297 - 306
  • [35] Remote-controlled magnetic pulmonary vein isolation combined with superior vena cava isolation for paroxysmal atrial fibrillation: A prospective randomized study
    Da Costa, Antoine
    Levallois, Marie
    Romeyer-Bouchard, Cecile
    Bisch, Laurence
    Gate-Martinet, Alexis
    Isaaz, Karl
    [J]. ARCHIVES OF CARDIOVASCULAR DISEASES, 2015, 108 (03) : 163 - 171
  • [36] The role of local impedance drop in the acute lesion efficacy during pulmonary vein isolation performed with a new contact force sensing catheter-A pilot study
    Szegedi, Nandor
    Sallo, Zoltan
    Perge, Peter
    Piros, Katalin
    Nagy, Vivien Klaudia
    Osztheimer, Istvan
    Merkely, Bela
    Geller, Laszlo
    [J]. PLOS ONE, 2021, 16 (09):
  • [37] Contact force sensing technology identifies sites of inadequate contact and reduces acute pulmonary vein reconnection: A prospective case control study
    Haldar, Shouvik
    Jarman, Julian W. E.
    Panikker, Sandeep
    Jones, David G.
    Salukhe, Tushar
    Gupta, Dhiraj
    Wynn, Gareth
    Hussain, Wajid
    Markides, Vias
    Wong, Tom
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 168 (02) : 1160 - 1166
  • [38] The Anatomic Impact of Sequential, Additional, Ostial Radiofrequency Ablation Following Pulmonary Vein Cryo-Isolation
    Traulle, Sarah
    Miyazaki, Shinsuke
    Mouquet, Vincent
    Kubala, Maciej
    Hermida, Jean-Sylvain
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2012, 35 (12): : 1420 - 1427
  • [39] Impact of cryoballoon contact angle and acute myocardial injury on pulmonary vein reconnection
    Masamichi Yano
    Yasuyuki Egami
    Shodai Kawanami
    Hiroki Sugae
    Kohei Ukita
    Akito Kawamura
    Hitoshi Nakamura
    Yutaka Matsuhiro
    Koji Yasumoto
    Masaki Tsuda
    Naotaka Okamoto
    Yasuharu Matsunaga-Lee
    Masami Nishino
    Jun Tanouchi
    [J]. Heart and Vessels, 2022, 37 : 1882 - 1891
  • [40] Adenosine-Guided Pulmonary Vein Antral Isolation for Paroxysmal Atrial Fibrillation: A Randomized Study
    Efremidis, Michael
    Letsas, Konstantinos P.
    Lioni, Louiza
    Vlachos, Konstantinos
    Georgopoulos, Stamatis
    Saplaouras, Athanasios
    Geladari, Eleni
    Giannopoulos, George
    Liu, Tong
    Deftereos, Spyridon
    Sideris, Antonios
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2016, 27 (11) : 1288 - 1292