Impact of Contact Force Monitoring in Acute Pulmonary Vein Isolation Using an Anatomic Approach. A Randomized Study

被引:20
|
作者
Pedrote, Alonso [1 ]
Arana-Rueda, Eduardo [1 ]
Arce-Leon, Alvaro [1 ]
Acosta, Juan [2 ]
Gomez-Pulido, Federico [1 ]
Luis Martos-Maine, Jose [1 ]
Frutos-Lopez, Manuel [1 ]
Sanchez-Brotons, Juan [1 ]
Garcia-Riesco, Lorena [1 ]
机构
[1] Hosp Univ Virgen del Rocio, Arrhythmia Unit, Serv Cardiol, Avda Manuel Siurot S-N, Seville 41013, Spain
[2] Hosp Clin Barcelona, Dept Cardiol, Arrhythmia Sect, Barcelona, Spain
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2016年 / 39卷 / 04期
关键词
atrial fibrillation ablation; contact force monitoring; pulmonary vein gaps; radiofrequency ablation; Carto system; PAROXYSMAL ATRIAL-FIBRILLATION; RADIOFREQUENCY CATHETER ABLATION; SENSING TECHNOLOGY; RECONNECTION; MULTICENTER; TRIAL;
D O I
10.1111/pace.12811
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundThe impact of contact force (CF) monitoring in pulmonary vein (PV) isolation after a circumferential anatomic ablation (CAA) is unknown. We analyze the usefulness of CF monitoring in acute PV isolation and procedure parameters using a CAA. MethodsFifty patients with paroxysmal atrial fibrillation were randomized into CF-on (CF >10 grams; n = 25) or CF-off (CF blinded; n = 25) groups. We performed a first round of CAA with a ThermoCool((R)) SmartTouch((R)) catheter blinded to the LASSO((R)) catheter (Biosense Webster, Diamond Bar, CA, USA), with radiofrequency (RF) lesions tagged with the VisiTag Module. After the CAA, each PV was reviewed with the LASSO((R)) catheter recording the segments with gaps. ResultsAll the PVs were isolated with a CAA in 20 patients of the CF-on versus eight of the CF-off (P = 0.001). Of the 45 segments with gaps in the left PVs, 38 were from the CF-off (P = 0.0001). Of the eight segments with gaps in the right PVs, seven were from the CF-off (P = 0.06). The CF in the left PVs was higher in the CF-on (16.3 3.2 grams vs 10.5 +/- 4.3 grams; P = 0.0001) and similar in the right PVs (17.6 +/- 3.6 grams vs 15.2 +/- 5.3 grams; P = 0.08). All of the gaps were closed with additional RF LASSO((R))-guided touch-up. Procedure and fluoroscopy times were shorter in the CF-on (139 +/- 24 minutes vs 157 +/- 32 minutes and 20 +/- 6 minutes vs 24 +/- 7 minutes; both P = 0.039). At 12 months the AF recurrence was 84% CF-on versus 75% CF-off (log-rank P = 0.4). ConclusionsIn paroxysmal atrial fibrillation, a CAA guided by CF reduces PV gaps and shortens the procedure parameters at the expense of the left PVs.
引用
收藏
页码:361 / 369
页数:9
相关论文
共 50 条
  • [1] Randomized trial comparing pulmonary vein isolation using the SmartTouch catheter with or without real-time contact force data
    Ullah, Waqas
    McLean, Ailsa
    Tayebjee, Muzahir H.
    Gupta, Dhiraj
    Ginks, Matthew R.
    Haywood, Guy A.
    O'Neill, Mark
    Lambiase, Pier D.
    Earley, Mark J.
    Schilling, Richard J.
    HEART RHYTHM, 2016, 13 (09) : 1761 - 1767
  • [2] Recurrence after pulmonary vein isolation is associated with low contact force
    Tofig, Bawer Jalal
    Lukac, Peter
    Borregaard, Rune
    Nielsen, Jan Moller
    Jensen, Henrik Kjaerulf
    Gerdes, Christian
    Kristensen, Jens
    Nielsen, Jens Cosedis
    Kristiansen, Steen Buus
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2018, 52 (01) : 28 - 33
  • [3] Contact force facilitates the achievement of an unexcitable ablation line during pulmonary vein isolation
    Schaeffer, Benjamin
    Willems, Stephan
    Meyer, Christian
    Lueker, Jakob
    Akbulak, Ruken O.
    Moser, Julia
    Jularic, Mario
    Eickholt, Christian
    Schwarzl, Jana M.
    Gunawardene, Melanie
    Kuklik, Pawel
    Sultan, Arian
    Hoffmann, Boris A.
    Steven, Daniel
    CLINICAL RESEARCH IN CARDIOLOGY, 2018, 107 (08) : 632 - 641
  • [4] Operator-blinded contact force monitoring during pulmonary vein isolation using conventional and steerable sheaths
    Kimura, Takehiro
    Takatsuki, Seiji
    Oishi, Ako
    Negishi, Masachika
    Kashimura, Shin
    Katsumata, Yoshinori
    Nishiyama, Takahiko
    Nishiyama, Nobuhiro
    Tanimoto, Yoko
    Aizawa, Yoshiyasu
    Fukuda, Keiichi
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 177 (03) : 970 - 976
  • [5] Reduced residual conduction gaps and favourable outcome in contact force-guided circumferential pulmonary vein isolation
    Itoh, Taihei
    Kimura, Masaomi
    Tomita, Hirofumi
    Sasaki, Shingo
    Owada, Shingen
    Horiuchi, Daisuke
    Sasaki, Kenichi
    Ishida, Yuji
    Kinjo, Takahiko
    Okumura, Ken
    EUROPACE, 2016, 18 (04): : 531 - 537
  • [6] Clinical impact of contact force and its regional variability on efficiency and effectiveness of pulmonary vein isolation for atrial fibrillation
    Sotomi, Yohei
    Inoue, Koichi
    Kikkawa, Takayuki
    Tanaka, Koji
    Toyoshima, Yuko
    Oka, Takafumi
    Tanaka, Nobuaki
    Orihara, Yoshiyuki
    Iwakura, Katsuomi
    Sakata, Yasushi
    Fujii, Kenshi
    JOURNAL OF CARDIOLOGY, 2016, 68 (3-4) : 335 - 341
  • [7] Is the knowledge of contact force beneficial in pulmonary vein antrum isolation?
    Borregaard, Rune
    Jensen, Henrik Kjaerulf
    Tofig, Bawer Jalal
    Thrysoe, Samuel Alberg
    Gerdes, Christian
    Nielsen, Jens Cosedis
    Lukac, Peter
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2017, 51 (03) : 129 - 137
  • [8] Impact of left atrial size on isolation area in the acute phase of pulmonary vein isolation using 28mm cryoballoon
    Chikata, Akio
    Kato, Takeshi
    Usuda, Kazuo
    Fujita, Shuhei
    Maruyama, Michiro
    Nagata, Yoshiki
    Sakagami, Satoru
    Kanamori, Naomi
    Yaegashi, Takanori
    Saeki, Takahiro
    Kusayama, Takashi
    Usui, Soichiro
    Furusho, Hiroshi
    Kaneko, Shuichi
    Takamura, Masayuki
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2018, 41 (07): : 700 - 706
  • [9] Prospective Characterization of Catheter-Tissue Contact Force at Different Anatomic Sites During Antral Pulmonary Vein Isolation
    Kumar, Saurabh
    Morton, Joseph B.
    Lee, Justin
    Halloran, Karen
    Spence, Steven J.
    Gorelik, Alexandra
    Hepworth, Graham
    Kistler, Peter M.
    Kalman, Jonathan M.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2012, 5 (06) : 1124 - 1129
  • [10] Electrical Reconnection After Pulmonary Vein Isolation Is Contingent on Contact Force During Initial Treatment Results From the EFFICAS I Study
    Neuzil, Petr
    Reddy, Vivek Y.
    Kautzner, Josef
    Petru, Jan
    Wichterle, Dan
    Shah, Dipen
    Lambert, Hendrik
    Yulzari, Aude
    Wissner, Erik
    Kuck, Karl-Heinz
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2013, 6 (02) : 327 - 333