Human behavior in a staircase during a total evacuation drill in a high-rise building

被引:19
作者
Sano, Tomonori [1 ]
Yajima, Masanori [2 ]
Kadokura, Hiroyuki [3 ]
Sekizawa, Ai [4 ]
机构
[1] Waseda Univ, Sch Human Sci, Mikajima 2-579-15, Tokorozawa, Saitama 3591192, Japan
[2] NTT Docomo Inc, Chiyoda Ku, Sanno Pk Tower 11-1,Nagata Cho 2 Chome, Tokyo 1006150, Japan
[3] Tokyu Res Inst Inc, Shibuya Ku, Dogenzaka 1-10-7, Tokyo 1500043, Japan
[4] Tokyo Univ Sci, Shinjuku Ku, Kagurazaka 1-3, Tokyo 1620825, Japan
基金
日本学术振兴会;
关键词
evacuation; high-rise building; drill; merging ratio; MOVEMENT;
D O I
10.1002/fam.2388
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Many studies have been conducted on the evacuation behavior on the staircases of buildings, but very little data are available for a situation with many occupants in a crowded high-rise building. Therefore, this study investigated the evacuation behavior of a large number of evacuees on the staircase of a 25-story high-rise building. A total evacuation drill was conducted with 2088 evacuees, and the behavior of 1136 evacuees on the landings of the south staircase was recorded by a video recorder on the ceiling. The relationship between the density and speed of the evacuees on the landings was analyzed from the evacuation data for two situations: without and with merging in the stair flow. The evacuation stair flow in this drill had merging occupants entering from the floors, but no one entered from the lower floors during the latter period of the drill. Therefore, the flow during the latter period was treated as non-merging flow, for which it was observed that, when the staircase was fully crowded, the density on the landings in the moving situation was different from that in the stopped situation. Moreover, the density on the landings was different from that on the treads. Furthermore, in the merging flow, a merging ratio of approximately 50:50 occurred during the congested evacuation. Copyright (C) 2016 John Wiley & Sons, Ltd.
引用
收藏
页码:375 / 386
页数:12
相关论文
共 14 条
[1]  
[Anonymous], 2005, FIRE SAF SCI, DOI DOI 10.3801/IAFSS.FSS.8-591
[2]   Experimental studies to investigate merging behaviour in a staircase [J].
Boyce, Karen E. ;
Purser, David A. ;
Shields, T. Jim .
FIRE AND MATERIALS, 2012, 36 (5-6) :383-398
[3]  
DiNenno P. J., 2008, SFPE Handbook of Fire Protection Engineering
[4]  
Fruin JohnJ., 1987, Pedestrian Planning and Design
[5]   Investigating the Representation of Merging Behavior at the Floor-Stair Interface in Computer Simulations of Multi-Floor Building Evacuations [J].
Galea, E. R. ;
Sharp, G. ;
Lawrence, P. J. .
JOURNAL OF FIRE PROTECTION ENGINEERING, 2008, 18 (04) :291-316
[6]   Questioning the linear relationship between doorway width and achievable flow rate [J].
Gwynne, S. M. V. ;
Kuligowski, E. D. ;
Kratchman, J. ;
Milke, J. A. .
FIRE SAFETY JOURNAL, 2009, 44 (01) :80-87
[7]  
Hokugo A., 1985, Journal of Architecture, Planning and Environmental Engineering, V358, P37, DOI 10.3130/aijax.358.0_37
[8]   Differences in measurement methods for travel distance and area for estimates of occupant speed on stairs [J].
Hoskins, Bryan L. ;
Milke, James A. .
FIRE SAFETY JOURNAL, 2012, 48 :49-57
[9]  
Kagawa M, 1986, FIRE SAFETY SCI, V1, P553
[10]  
Kuligowski E.D, 2014, 1839 NIST, P1