3D Printing of CT Dataset: Validation of an Open Source and Consumer-Available Workflow

被引:18
作者
Bortolotto, Chandra [1 ]
Eshja, Esmeralda [1 ]
Peroni, Caterina [1 ]
Orlandi, Matteo A. [1 ]
Bizzotto, Nicola [2 ]
Poggi, Paolo [1 ]
机构
[1] Osped Maggiore Lodi, Dept Radiol, Lodi, Italy
[2] Azienda Osped Univ Polo Chirurg Confortini, Verona, Italy
关键词
Multidetector computed tomography; Computer-aided design; Printing; Imaging three-dimensional; Dimensional measurement accuracy; 3-DIMENSIONAL COMPUTED-TOMOGRAPHY; MODELS; ACCURACY; ANATOMY;
D O I
10.1007/s10278-015-9810-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The broad availability of cheap three-dimensional (3D) printing equipment has raised the need for a thorough analysis on its effects on clinical accuracy. Our aim is to determine whether the accuracy of 3D printing process is affected by the use of a low-budget workflow based on open source software and consumer's commercially available 3D printers. A group of test objects was scanned with a 64-slice computed tomography (CT) in order to build their 3D copies. CT datasets were elaborated using a software chain based on three free and open source software. Objects were printed out with a commercially available 3D printer. Both the 3D copies and the test objects were measured using a digital professional caliper. Overall, the objects' mean absolute difference between test objects and 3D copies is 0.23 mm and the mean relative difference amounts to 0.55 %. Our results demonstrate that the accuracy of 3D printing process remains high despite the use of a low-budget workflow.
引用
收藏
页码:14 / 21
页数:8
相关论文
共 16 条
[1]   Comparison of three-dimensional computed tomography with rapid prototype models in the management of coronoid hyperplasia [J].
Asaumi, J ;
Kawai, N ;
Honda, Y ;
Shigehara, H ;
Wakasa, T ;
Kishi, K .
DENTOMAXILLOFACIAL RADIOLOGY, 2001, 30 (06) :330-335
[2]   Three-Dimensional Printing of Bone Fractures: A New Tangible Realistic Way for Preoperative Planning and Education [J].
Bizzotto, Nicola ;
Sandri, Andrea ;
Regis, Dario ;
Romani, Denis ;
Tami, Ivan ;
Magnan, Bruno .
SURGICAL INNOVATION, 2015, 22 (05) :548-551
[3]  
El-Katatny I, 2010, RAPID PROTOTYPING J, V16, p36e43
[4]   Clinical Applications of Physical 3D Models Derived From MDCT Data and Created by Rapid Prototyping [J].
Esses, Steven J. ;
Berman, Phillip ;
Bloom, Allan I. ;
Sosna, Jacob .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (06) :W683-W688
[5]   A critical inventory of preoperative skull replicas [J].
Fasel, J. H. D. ;
Beinemann, J. ;
Schaller, K. ;
Gailloud, P. .
ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2013, 95 (06) :401-404
[6]   Segmentation process significantly influences the accuracy of 3D surface models derived from cone beam computed tomography [J].
Fourie, Zacharias ;
Damstra, Janalt ;
Schepers, Rutger H. ;
Gerrits, Peter O. ;
Ren, Yijin .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (04) :E524-E530
[7]  
Frühwald J, 2008, J CRANIOFAC SURG, V19, P22, DOI 10.1097/scs.0b013e318052ff1a
[8]   Inaccuracies in additive manufactured medical skull models caused by the DICOM to STL conversion process [J].
Huotilainen, Eero ;
Jaanimets, Risto ;
Valasek, Jiri ;
Marcian, Petr ;
Salmi, Mika ;
Tuomi, Jukka ;
Makitie, Antti ;
Wolff, Jan .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2014, 42 (05) :E259-E265
[9]   Dimensional error of selective laser sintering, three-dimensional printing and PolyJet™ models in the reproduction of mandibular anatomy [J].
Ibrahim, Danilo ;
Broilo, Tiago Leonardo ;
Heitz, Claiton ;
de Oliveira, Marilia Gerhardt ;
de Oliveira, Helena Willhelm ;
Wanderlei Nobre, Stella Maris ;
Dos Santos Filho, Jose Henrique Gomes ;
Silva, Daniela Nascimento .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2009, 37 (03) :167-173
[10]  
Murugesan K, 2012, J Indian Prosthodont Soc, V12, P16, DOI 10.1007/s13191-011-0103-8