Nonlinear ablation targeting an isthmus of critically slow conduction detected by high-density electroanatomical mapping for atypical atrial flutter

被引:0
作者
Iesaka, Y
Takahashi, A
Goya, M
Fujiwara, H
Nitta, J
Nogami, A
Aonuma, K
Hiroe, M
Marumo, F
Hiraoka, M
机构
[1] Tsuchiura Kyodo Gen Hosp, Ctr Cardiovasc, Tsuchiura, Ibaraki 3000053, Japan
[2] Tokyo Med & Dent Univ, Sch Med, Dept Internal Med 2, Tokyo, Japan
[3] Tokyo Med & Dent Univ, Med Res Inst, Dept Cardiovasc Dis, Tokyo, Japan
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2000年 / 23卷 / 11期
关键词
atypical atrial flutter; macroreentrant atrial tachycardia; electroanatomical mapping; figure-8; reentry; isthmus of slow conduction; nonlinear catheter ablation;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Focused high-density atrial endocardial mapping was performed with a three-dimensional electroanatomical mapping system or a multielectrode basket catheter in six men and two women (mean age = 54 years) with atypical atrial flutter (AFL) to characterize its reentry circuit and identify its isthmus of critically slow conduction (ICSC). Activation mapping revealed figure-8 reentry with ICSC between a surgical atrial scars in three atypical AFLs following atriotomy, and between the crista terminalis (CT) and the inferior (IVC) or superior (SVC) vena cavae in atypical right atrial (RA) AFL in absence of prior atriotomy. Figure-8 double loop reentry was documented in one RA atypical AFL. ICSC was characterized by concealed entrainment with a post-pacing interval identical to the AFL cycle length, and a mid-diastolic fractionated electrogram, 129 +/- 23 ms in duration, spanning the isoelectric line between double potentials on adjacent area of conduction block. All AFLs were successfully ablated with 4.9 +/- 4.3 RF pulses applied at ICSC. A possible mechanism of atypical AFL consists of figure-8 reentry with ICSC between surgical scars in postoperative AFL, and between the CT and the IVC/SVC in RA AFL not preceded by cardiac surgery. Late and partial regeneration of conduction across the atriotomy scar can create an ICSC. Nonlinear ablation targeting ICSC can cure atypical AFL, whether it follows surgery or not.
引用
收藏
页码:1911 / 1915
页数:5
相关论文
共 15 条
[1]   ATRIOATRIAL CONDUCTION AFTER ORTHOTOPIC HEART-TRANSPLANTATION [J].
ANSELME, F ;
SAOUDI, N ;
REDONNET, M ;
LETAC, B .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (01) :185-189
[2]   Catheter ablation of clinical intraatrial reentrant tachycardias resulting from previous atrial surgery: Localizing and transecting the critical isthmus [J].
Baker, BM ;
Lindsay, BD ;
Bromberg, BI ;
Frazier, DW ;
Cain, ME ;
Smith, JM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 28 (02) :411-417
[3]   Ablation of atypical atrial flutter guided by the use of concealed entrainment in patients without prior cardiac surgery [J].
Bogun, F ;
Bender, B ;
Li, YG ;
Hohnloser, SH .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2000, 11 (02) :136-145
[4]   Electroanatomical mapping and ablation of the substrate supporting intraatrial reentrant tachycardia after palliation for complex congenital heart disease [J].
Dorostkar, PC ;
Cheng, J ;
Scheinman, MM .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (09) :1810-1819
[5]  
Gepstein L, 1997, CIRCULATION, V95, P1611
[6]  
IESAKA Y, 1999, PACE, V22, P868
[7]   Atypical atrial flutter originating in the right atrial free wall [J].
Kall, JG ;
Rubenstein, DS ;
Kopp, DE ;
Burke, MC ;
Verdino, RJ ;
Lin, AC ;
Johnson, CT ;
Cooke, PA ;
Wang, ZG ;
Fumo, M ;
Wilber, DJ .
CIRCULATION, 2000, 101 (03) :270-279
[8]   Ablation of 'incisional' reentrant atrial tachycardia complicating surgery for congenital heart disease - Use of entrainment to define a critical isthmus of conduction [J].
Kalman, JM ;
VanHare, GF ;
Olgin, JE ;
Saxon, LA ;
Stark, SI ;
Lesh, MD .
CIRCULATION, 1996, 93 (03) :502-512
[9]   Use of a 3-dimensional electroanatomical mapping system for catheter ablation of macroreentrant right atrial tachycardia following atriotomy [J].
Nakagawa, H ;
Jackman, WM .
JOURNAL OF ELECTROCARDIOLOGY, 1999, 32 :16-21
[10]   Use of a three-dimensional, nonfluoroscopic mapping system for catheter ablation of typical atrial flutter [J].
Nakagawa, H ;
Jackman, WM .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (06) :1279-1286