Building the repertoire of measures of walking in Rett syndrome

被引:23
作者
Stahlhut, Michelle [1 ,2 ]
Downs, Jenny [3 ,4 ]
Leonard, Helen [3 ]
Bisgaard, Anne-Marie [2 ]
Nordmark, Eva [1 ]
机构
[1] Lund Univ, Dept Hlth Sci, Fac Med, Lund, Sweden
[2] Rigshosp, Dept Clin Genet, Ctr Rett Syndrome, Kennedy Ctr, Gamle Landevej 7, DK-2600 Glostrup, Denmark
[3] Univ Western Australia, Telethon Kids Inst, Perth, WA, Australia
[4] Curtin Univ, Sch Physiotherapy & Exercise Sci, Perth, WA, Australia
关键词
Rett syndrome; walking; functional mobility scale; two-minute walk test; TEST-RETEST RELIABILITY; FUNCTIONAL MOBILITY SCALE; CEREBRAL-PALSY; DISABILITY INVENTORY; PEDIATRIC EVALUATION; 6-MINUTE; CHILDREN; 2-MINUTE; ADULTS; GIRLS;
D O I
10.1080/09638288.2016.1212280
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Background: The repertoire of measures of walking in Rett syndrome is limited. This study aimed to determine measurement properties of a modified two-minute walk test (2MWT) and a modified Rett syndrome-specific functional mobility scale (FMS-RS) in Rett syndrome. Methods: Forty-two girls and women with Rett syndrome (median 18.4 years, range 2.4-60.9 years) were assessed for clinical severity, gross motor skills, and mobility. To measure walking capacity, 27 of this group completed a 2MWT twice on two different assessment days. To assess walking performance, the FMS-RS was administered to the total sample of parents (n=42) on two occasions approximately one week apart. Results: There were negative correlations between clinical severity and 2MWT (r=-0.48) and FMS-RS (r=-0.60-0.66). There were positive correlations between gross motor skills and mobility and 2MWT (r=0.51, 0.43) and FMS-RS (r=0.71-0.93, 0.74-0.94), respectively. Test-retest reliability for the 2MWT was good with high intraday and interday correlations (ICC=0.86-0.98). For the 2MWT, the standard error of measurement was 13.8 m and we would be 95% confident that changes greater than 38 m would be greater than within subject error. There was good test-retest reliability for all three distances on the FMS-RS (ICC=0.94-0.99). Conclusions: Walking capacity as measured by the 2MWT showed expected but limited relationships with measures of different constructs, providing some support for concurrent validity. Walking performance as measured with the FMS-RS was more strongly consistent with other clinical measures supporting its concurrent validity. Test-retest reliability was good for both the FMS-RS and the 2MWT. Therefore, these measures have the potential to be used in clinical practice and research.
引用
收藏
页码:1926 / 1931
页数:6
相关论文
共 43 条
[1]   Rett syndrome is caused by mutations in X-linked MECP2, encoding methyl-CpG-binding protein 2 [J].
Amir, RE ;
Van den Veyver, IB ;
Wan, M ;
Tran, CQ ;
Francke, U ;
Zoghbi, HY .
NATURE GENETICS, 1999, 23 (02) :185-188
[2]   Twenty years of surveillance in Rett syndrome: what does this tell us? [J].
Anderson, Alison ;
Wong, Kingsley ;
Jacoby, Peter ;
Downs, Jenny ;
Leonard, Helen .
ORPHANET JOURNAL OF RARE DISEASES, 2014, 9
[3]  
[Anonymous], 1992, PEDIAT EVALUATION DI
[4]   Is it possible to diagnose Rett syndrome before classical symptoms become obvious? Review of 24 Danish cases born between 2003 and 2012 [J].
Bisgaard, Anne-Marie ;
Schonewolf-Greulich, Bitten ;
Ravn, Kirstine ;
Ronde, Gitte .
EUROPEAN JOURNAL OF PAEDIATRIC NEUROLOGY, 2015, 19 (06) :679-687
[5]   Two-Minute Walk Test Performance by Adults 18 to 85 Years: Normative Values, Reliability, and Responsiveness [J].
Bohannon, Richard W. ;
Wang, Ying-Chih ;
Gershon, Richard C. .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2015, 96 (03) :472-477
[6]   Comparison of walking performance over the first 2 minutes and the full 6 minutes of the Six-Minute Walk Test [J].
Bohannon R.W. ;
Bubela D. ;
Magasi S. ;
McCreath H. ;
Wang Y.-C. ;
Reuben D. ;
Rymer W.Z. ;
Gershon R. .
BMC Research Notes, 7 (1)
[7]   The two-minute walk test as a measure of functional capacity in cardiac surgery patients [J].
Brooks, D ;
Parsons, J ;
Tran, D ;
Jeng, B ;
Gorczyca, B ;
Newton, J ;
Lo, V ;
Dear, C ;
Silaj, E ;
Hawn, T .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2004, 85 (09) :1525-1530
[8]   Test-Retest Reliability of the 6-Minute Walk Test in Individuals With Down Syndrome [J].
Casey, Amanda F. ;
Wang, Xu ;
Osterling, Kristin .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2012, 93 (11) :2068-2074
[9]   Findings from a multidisciplinary clinical case series of females with Rett syndrome [J].
Cass, H ;
Reilly, S ;
Owen, L ;
Wisbeach, A ;
Weekes, L ;
Slonims, V ;
Wigram, T ;
Charman, T .
DEVELOPMENTAL MEDICINE AND CHILD NEUROLOGY, 2003, 45 (05) :325-337
[10]   Clinical Utility of the 2-Minute Walk Test for Older Adults Living in Long-Term Care [J].
Connelly, D. M. ;
Thomas, B. K. ;
Cliffe, S. J. ;
Perry, W. M. ;
Smith, R. E. .
PHYSIOTHERAPY CANADA, 2009, 61 (02) :78-87