Novel imaging strategies for the detection of prosthetic heart valve obstruction and endocarditis

被引:23
作者
Tanis, W. [1 ]
Budde, R. P. J. [2 ]
van der Bilt, I. A. C. [1 ]
Delemarre, B. [1 ]
Hoohenkerk, G. [3 ]
van Rooden, J. -K. [4 ]
Scholtens, A. M. [5 ]
Habets, J. [5 ]
Chamuleau, S. [1 ]
机构
[1] Haga Teaching Hosp, Dept Cardiol, Leyweg 275, NL-2545 CH The Hague, Netherlands
[2] Erasmus MC, Dept Radiol, Rotterdam, Netherlands
[3] Haga Teaching Hosp, Dept Cardiothorac Surg, NL-2545 CH The Hague, Netherlands
[4] Haga Teaching Hosp, Dept Radiol, NL-2545 CH The Hague, Netherlands
[5] Univ Med Ctr Utrecht, Dept Nucl Med, Utrecht, Netherlands
关键词
Prosthetic heart valve; Endocarditis; Thrombosis; Pannus; Multidetector-row computed tomography; 18-fluorine-fluorodesoxy glucose positron emission tomography; EMISSION TOMOGRAPHY/COMPUTED TOMOGRAPHY; 3-DIMENSIONAL TRANSESOPHAGEAL ECHOCARDIOGRAPHY; COMPUTED-TOMOGRAPHY; INFECTIVE ENDOCARDITIS; DIAGNOSTIC-ACCURACY; F-18-FDG PET/CT; ANGIOGRAPHY; THROMBOSIS; PANNUS; RING;
D O I
10.1007/s12471-015-0796-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Prosthetic heart valve (PHV) dysfunction remains difficult to recognise correctly by two-dimensional (2D) transthoracic and transoesophageal echocardiography (TTE/TEE). ECG-triggered multidetector-row computed tomography (MDCT), 18-fluorine-fluorodesoxyglucose positron emission tomography including low-dose CT (FDG-PET) and three-dimensional transoesophageal echocardiography (3D-TEE) may have additional value. This paper reviews the role of these novel imaging tools in the field of PHV obstruction and endocarditis. For acquired PHV obstruction, MDCT is of additional value in mechanical PHVs to differentiate pannus from thrombus as well as to dynamically study leaflet motion and opening/closing angles. For biological PHV obstruction, additional imaging is not beneficial as it does not change patient management. When performed on top of 2D-TTE/TEE, MDCT has additional value for the detection of both vegetations and pseudoaneurysms/abscesses in PHV endocarditis. FDG-PET has no complementary value for the detection of vegetations; however, it appears more sensitive in the early detection of pseudoaneurysms/abscesses. Furthermore, FDG-PET enables the detection of metastatic and primary extra-cardiac infections. Evidence for the additional value of 3D-TEE is scarce. As clinical implications are major, clinicians should have a low threshold to perform additional MDCT in acquired mechanical PHV obstruction. For suspected PHV endocarditis, both FDG-PET and MDCT have complementary value.
引用
收藏
页码:96 / 107
页数:12
相关论文
共 50 条
[1]  
Alberto J, 1999, AM J CARDIOL, V83, P1075
[2]   Imaging the prosthetic valve sewing ring thrombosis using real-time three-dimensional transoesophageal echocardiography [J].
Alexandrescu, C. ;
Negrea, S. L. ;
Civaia, F. ;
Dreyfus, G. .
NETHERLANDS HEART JOURNAL, 2013, 21 (11) :521-523
[3]   Differentiating thrombus from pannus formation in obstructed mechanical prosthetic valves: An evaluation of clinical, transthoracic and transesophageal echocardiographic parameters [J].
Barbetseas, J ;
Nagueh, SF ;
Pitsavos, C ;
Toutouzas, PK ;
Quinones, MA ;
Zoghbi, WA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (05) :1410-1417
[4]   CONTINUOUS WAVE DOPPLER ECHOCARDIOGRAPHIC MEASUREMENT OF PROSTHETIC VALVE GRADIENTS - A SIMULTANEOUS DOPPLER-CATHETER CORRELATIVE STUDY [J].
BURSTOW, DJ ;
NISHIMURA, RA ;
BAILEY, KR ;
REEDER, GS ;
HOLMES, DR ;
SEWARD, JB ;
TAJIK, AJ .
CIRCULATION, 1989, 80 (03) :504-514
[5]   PATHOLOGICAL AND ANGIOGRAPHIC CORRELATIONS OF TRANSESOPHAGEAL ECHOCARDIOGRAPHY IN PROSTHETIC HEART-VALVE DYSFUNCTION [J].
CHAUDHRY, FA ;
HERRERA, C ;
DEFRINO, PF ;
MEHLMAN, DJ ;
ZABALGOITIA, M .
AMERICAN HEART JOURNAL, 1991, 122 (04) :1057-1064
[6]   Perivalvular abscesses associated with endocarditis - Clinical features and prognostic factors of overall survival in a series of 233 cases [J].
Choussat, R ;
Thomas, D ;
Isnard, R ;
Michel, PL ;
Lung, B ;
Hanania, G ;
Mathieu, P ;
David, M ;
de Chaumaray, TD ;
De Gevigney, G ;
Le Breton, H ;
Logeais, Y ;
Pierre-Justin, E ;
de Riberolles, C ;
Morvan, Y ;
Bischoff, N .
EUROPEAN HEART JOURNAL, 1999, 20 (03) :232-241
[7]   IMPROVEMENT IN THE DIAGNOSIS OF ABSCESSES ASSOCIATED WITH ENDOCARDITIS BY TRANSESOPHAGEAL ECHOCARDIOGRAPHY [J].
DANIEL, WG ;
MUGGE, A ;
MARTIN, RP ;
LINDERT, O ;
HAUSMANN, D ;
NONNASTDANIEL, B ;
LAAS, J ;
LICHTLEN, PR .
NEW ENGLAND JOURNAL OF MEDICINE, 1991, 324 (12) :795-800
[8]   NEW CRITERIA FOR DIAGNOSIS OF INFECTIVE ENDOCARDITIS - UTILIZATION OF SPECIFIC ECHOCARDIOGRAPHIC FINDINGS [J].
DURACK, DT ;
LUKES, AS ;
BRIGHT, DK ;
ALBERTS, MJ ;
BASHORE, TM ;
COREY, GR ;
DOUGLAS, JM ;
GRAY, L ;
HARRELL, FE ;
HARRISON, JK ;
HEINLE, SA ;
MORRIS, A ;
KISSLO, JA ;
NICELY, LM ;
OLDHAM, N ;
PENNING, LM ;
SEXTON, DJ ;
TOWNS, M ;
WAUGH, RA .
AMERICAN JOURNAL OF MEDICINE, 1994, 96 (03) :200-209
[9]  
Edwards M B, 2000, J Magn Reson Imaging, V12, P363, DOI 10.1002/1522-2586(200008)12:2<363::AID-JMRI21>3.0.CO
[10]  
2-3