Resin composite repair for implant-supported crowns

被引:11
作者
Bonfante, Estevam A. [1 ]
Suzuki, Marcelo [2 ]
Hirata, Ronaldo [3 ]
Bonfante, Gerson [1 ]
Fardin, Vinicius P. [1 ,3 ]
Coelho, Paulo G. [3 ,4 ,5 ]
机构
[1] Univ Sao Paulo, Bauru Coll Dent, Dept Prosthodont, Bauru, SP, Brazil
[2] Tufts Univ, Sch Dent Med, Dept Operat Dent & Prosthodont, Boston, MA 02111 USA
[3] NYU, Coll Dent, Dept Biomat & Biomimet, New York, NY 10010 USA
[4] NYU, Coll Dent, Dept Periodontol & Implant Dent, Res, New York, NY USA
[5] New York Univ Abu Dhabi, Div Engn, Abu Dhabi, U Arab Emirates
基金
巴西圣保罗研究基金会;
关键词
dental implant; crown; repair; fatigue; fractography; resin composites; FIXED DENTAL PROSTHESES; TAPERED INTERFERENCE FIT; FINITE-ELEMENT-ANALYSIS; FAILURE MODES; Y-TZP; ANTERIOR CROWNS; RESTORATIVE MATERIALS; SINGLE CROWNS; CORE DESIGN; RELIABILITY;
D O I
10.1002/jbm.b.33683
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study evaluated the reliability of implant-supported crowns repaired with resin composites. Fifty-four titanium abutments were divided in three groups (n = 18 each) to support resin nanoceramic molar crowns, as follows: (LU) (Lava Ultimate, 3M ESPE); LU repaired with either a direct or an indirect resin composite. Samples were subjected to mouth-motion accelerated-life testing in water (n 5 18). Cumulative damage with a use stress of 300 N was used to plot Weibull curves for group comparison. Reliability was calculated for a mission of 100,000 cycles at 400 N load. Beta values were 0.83 for LU, 0.31 and 0.27 for LU repaired with Filtek and Ceramage, respectively. Weibull modulus for LU was 9.5 and eta = 1047 N, m = 6.85, and eta = 1002 N for LU repaired with Ceramage, and m = 4.65 and eta = 766 N for LU repaired with Filtek (p < 0.10 between LU and LU repaired with Filtek). Reliability at 400 N was 100% for both LU and LU repaired with Ceramage which were significantly higher than LU Filtek repair (32%). LU restored crowns failed cohesively. Fractures were confined within the restored material, and detailed fractography is presented. The performance of resin nanoceramic material repaired with an indirect composite was maintained after accelerated-life testing compared to unrepaired controls. (C) 2016 Wiley Periodicals, Inc.
引用
收藏
页码:1481 / 1489
页数:9
相关论文
共 50 条
[1]  
Abernethy R., 2006, NEW WEIBULL HDB, P350
[2]   Mechanical Testing of Implant-Supported Anterior Crowns with Different Implant/Abutment Connections [J].
Almeida, Erika O. ;
Freitas, Amilcar C., Jr. ;
Bonfante, Estevam A. ;
Marotta, Leonard ;
Silva, Nelson R. F. A. ;
Coelho, Paulo G. .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (01) :103-108
[3]   Effect of microthread presence and restoration design (screw versus cemented) in dental implant reliability and failure modes [J].
Almeida, Erika O. ;
Freitas Junior, Amilcar C. ;
Bonfante, Estevam A. ;
Rocha, Eduardo Passos ;
Silva, Nelson R. F. A. ;
Coelho, Paulo G. .
CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 (02) :191-196
[4]   Standardizing failure, success, and survival decisions in clinical studies of ceramic and metal-ceramic fixed dental prostheses [J].
Anusavice, Kenneth J. .
DENTAL MATERIALS, 2012, 28 (01) :102-111
[5]   Implants for life? A critical review of implant-supported restorations [J].
Bartlett, David .
JOURNAL OF DENTISTRY, 2007, 35 (10) :768-772
[6]   Probability of survival of implant-supported metal ceramic and CAD/CAM resin nanoceramic crowns [J].
Bonfante, Estevam A. ;
Suzuki, Marcelo ;
Lorenzoni, Fabio C. ;
Sena, Lidia A. ;
Hirata, Ronaldo ;
Bonfante, Gerson ;
Coelho, Paulo G. .
DENTAL MATERIALS, 2015, 31 (08) :E168-E177
[7]   Fatigue and damage accumulation of veneer porcelain pressed on Y-TZP [J].
Bonfante, Estevam A. ;
Coelho, Paulo G. ;
Guess, Petra C. ;
Thompson, Van P. ;
Silva, Nelson R. F. A. .
JOURNAL OF DENTISTRY, 2010, 38 (04) :318-324
[8]   Thermal/mechanical simulation and laboratory fatigue testing of an alternative yttria tetragonal zirconia polycrystal core-veneer all-ceramic layered crown design [J].
Bonfante, Estevam A. ;
Rafferty, Brian ;
Zavanelli, Ricardo A. ;
Silva, Nelson R. F. A. ;
Rekow, Elizabeth D. ;
Thompson, Van P. ;
Coelho, Paulo G. .
EUROPEAN JOURNAL OF ORAL SCIENCES, 2010, 118 (02) :202-209
[9]   Effect of framework design on crown failure [J].
Bonfante, Estevam A. ;
da Silva, Nelson R. F. A. ;
Coelho, Paulo G. ;
Bayardo-Gonzalez, Daniel E. ;
Thompson, Van P. ;
Bonfante, Gerson .
EUROPEAN JOURNAL OF ORAL SCIENCES, 2009, 117 (02) :194-199
[10]   Abutment Design for Implant-Supported Indirect Composite Molar Crowns: Reliability and Fractography [J].
Bonfante, Estevam Augusto ;
Suzuki, Marcelo ;
Lubelski, William ;
Thompson, Van P. ;
de Carvalho, Ricardo Marins ;
Witek, Lukasz ;
Coelho, Paulo G. .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2012, 21 (08) :596-603