Efficacy of Maximum Intensity Projection of Contrast-Enhanced 3D Turbo-Spin Echo Imaging with Improved Motion-Sensitized Driven-Equilibrium Preparation in the Detection of Brain Metastases

被引:5
|
作者
Bae, Yun Jung [1 ]
Choi, Byung Se [1 ]
Lee, Kyung Mi [2 ]
Yoon, Yeon Hong [1 ]
Sunwoo, Leonard [1 ]
Jung, Cheolkyu [1 ]
Kim, Jae Hyoung [1 ]
机构
[1] Seoul Natl Univ, Bundang Hosp, Coll Med, Dept Radiol, 82 Gumi Ro 173Beon Gil, Seongnam 13620, South Korea
[2] Kyung Hee Univ, Coll Med, Kyung Hee Univ Hosp, Dept Radiol, Seoul 02447, South Korea
关键词
Brain; Neoplasm metastasis; Magnetic resonance imaging; 3; tesla; PULMONARY NODULES; STEREOTACTIC RADIOSURGERY; IMAGES; OBSERVER; CT; ACQUISITION; IMSDE;
D O I
10.3348/kjr.2017.18.4.699
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate the diagnostic benefits of 5-mm maximum intensity projection of improved motion-sensitized driven-equilibrium prepared contrast-enhanced 3D T1-weighted turbo-spin echo imaging (MIP iMSDE-TSE) in the detection of brain metastases. The imaging technique was compared with 1-mm images of iMSDE-TSE (non-MIP iMSDE-TSE), 1-mm contrast-enhanced 3D T1-weighted gradient-echo imaging (non-MIP 3D-GRE), and 5-mm MIP 3D-GRE. Materials and Methods: From October 2014 to July 2015, 30 patients with 460 enhancing brain metastases (size > 3 mm, n = 150; size = 3 mm, n = 310) were scanned with non-MIP iMSDE-TSE and non-MIP 3D-GRE. We then performed 5-mm MIP reconstruction of these images. Two independent neuroradiologists reviewed these four sequences. Their diagnostic performance was compared using the following parameters: sensitivity, reading time, and figure of merit (FOM) derived by jackknife alternative free-response receiver operating characteristic analysis. Interobserver agreement was also tested. Results: The mean FOM (all lesions, 0.984; lesions = 3 mm, 0.980) and sensitivity ([reader 1: all lesions, 97.3%; lesions = 3 mm, 96.2%], [reader 2: all lesions, 97.0%; lesions = 3 mm, 95.8%]) of MIP iMSDE-TSE was comparable to the mean FOM (0.985, 0.977) and sensitivity ([reader 1: 96.7, 99.0%], [reader 2: 97, 95.3%]) of non-MIP iMSDE-TSE, but they were superior to those of non-MIP and MIP 3D-GREs (all, p < 0.001). The reading time of MIP iMSDE-TSE (reader 1: 47.7 +/- 35.9 seconds; reader 2: 44.7 +/- 23.6 seconds) was significantly shorter than that of non-MIP iMSDE-TSE (reader 1: 78.8 +/- 43.7 seconds, p = 0.01; reader 2: 82.9 +/- 39.9 seconds, p < 0.001). Interobserver agreement was excellent (kappa > 0.75) for all lesions in both sequences. Conclusion: MIP iMSDE-TSE showed high detectability of brain metastases. Its detectability was comparable to that of non-MIP iMSDE-TSE, but it was superior to the detectability of non-MIP/MIP 3D-GREs. With a shorter reading time, the false-positive results of MIP iMSDE-TSE were greater. We suggest that MIP iMSDE-TSE can provide high diagnostic performance and low false-positive rates when combined with 1-mm sequences.
引用
收藏
页码:699 / 709
页数:11
相关论文
共 17 条
  • [1] 3D Turbo Spin-Echo Sequence with Motion-Sensitized Driven-Equilibrium Preparation for Detection of Brain Metastases on 3T MR Imaging
    Nagao, E.
    Yoshiura, T.
    Hiwatashi, A.
    Obara, M.
    Yamashita, K.
    Kamano, H.
    Takayama, Y.
    Kobayashi, K.
    Honda, H.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (04) : 664 - 670
  • [2] Improved motion-sensitized driven-equilibrium preparation for 3D turbo spin echo T1 weighted imaging after gadolinium administration for the detection of brain metastases on 3T MRI
    Lee, Sangjoon
    Park, Dong Woo
    Lee, Ji Young
    Lee, Young-Jun
    Kim, Taeyoon
    BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1063)
  • [3] Carotid and aortic plaque imaging using 3D gradient-echo imaging and the three-point Dixon method with improved motion-sensitized driven-equilibrium (iMSDE)
    Koori, Norikazu
    Kamekawa, Hiroki
    Naito, Takehiro
    Takatsu, Yasuo
    Fuse, Hiraku
    Miyakawa, Shin
    Yasue, Kenji
    Takahashi, Masato
    Kurata, Kazuma
    MAGNETIC RESONANCE IMAGING, 2024, 111 : 202 - 209
  • [4] Improved Blood Suppression of Motion-Sensitized Driven Equilibrium in High-Resolution Whole-Brain Vessel Wall Imaging: Comparison of Contrast-Enhanced 3D T1-Weighted FSE with Motion-Sensitized Driven Equilibrium and Delay Alternating with Nutation for Tailored Excitation
    Kim, D. J.
    Lee, H. -j.
    Baik, J.
    Hwang, M. J.
    Miyoshi, M.
    Kang, Y.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2022, 43 (12) : 1713 - 1718
  • [5] Feasibility of improved motion-sensitized driven-equilibrium (iMSDE) prepared 3D T1-weighted imaging in the diagnosis of vertebrobasilar artery dissection
    Choi, Jin Wook
    Han, Miran
    Hong, Ji Man
    Lee, Jin Soo
    Kim, Sun Yong
    Kim, Sam Soo
    JOURNAL OF NEURORADIOLOGY, 2018, 45 (03) : 186 - 191
  • [6] 3D T1-weighted turbo spin echo contrast-enhanced MRI at 1.5 T for frameless brain metastases radiotherapy
    Yuan, Jing
    Law, Stephen C. K.
    Wong, Ka Kin
    Lo, Gladys G.
    Kam, Michael K. M.
    Kwan, Wing Hong
    Xue, Cindy
    Wong, Oi Lei
    Yu, Siu Ki
    Cheung, Kin Yin
    JOURNAL OF CANCER RESEARCH AND CLINICAL ONCOLOGY, 2022, 148 (07) : 1749 - 1759
  • [7] Wall Enhancement of the Intracranial Aneurysms Revealed by Magnetic Resonance Vessel Wall Imaging Using Three-Dimensional Turbo Spin-Echo Sequence with Motion-Sensitized Driven-Equilibrium: A Sign of Ruptured Aneurysm?
    S. Nagahata
    M. Nagahata
    M. Obara
    R. Kondo
    N. Minagawa
    S. Sato
    S. Sato
    W. Mouri
    S. Saito
    T. Kayama
    Clinical Neuroradiology, 2016, 26 : 277 - 283
  • [8] Wall Enhancement of the Intracranial Aneurysms Revealed by Magnetic Resonance Vessel Wall Imaging Using Three-Dimensional Turbo Spin-Echo Sequence with Motion-Sensitized Driven-Equilibrium: A Sign of Ruptured Aneurysm?
    Nagahata, S.
    Nagahata, M.
    Obara, M.
    Kondo, R.
    Minagawa, N.
    Sato, S.
    Sato, S.
    Mouri, W.
    Saito, S.
    Kayama, T.
    CLINICAL NEURORADIOLOGY, 2016, 26 (03) : 277 - 283
  • [9] Detection of Advanced Lesions of Atherosclerosis in Carotid Arteries Using 3-Dimensional Motion-Sensitized Driven-Equilibrium Prepared Rapid Gradient Echo (3D-MERGE) Magnetic Resonance Imaging as a Screening Tool
    Geleri, Duygu Baylam
    Watase, Hiroko
    Chu, Baocheng
    Chen, Li
    Zhao, Huilin
    Zhao, Xihai
    Hatsukami, Thomas S.
    Yuan, Chun
    STROKE, 2022, 53 (01) : 194 - 200
  • [10] High Resolution Diffusion-Weighted Imaging for Solitary Orbital Tumors 3D Turbo Field Echo with Diffusion-Sensitized Driven-Equilibrium (DSDE-TFE) Preparation Technique
    Hiwatashi, Akio
    Togao, Osamu
    Yamashita, Koji
    Kikuchi, Kazufumi
    Yoshikawa, Hiroshi
    Obara, Makoto
    Honda, Hiroshi
    CLINICAL NEURORADIOLOGY, 2018, 28 (02) : 261 - 266