Using 100-instead of 120-kVp computed tomography to diagnose pulmonary embolism almost halves the radiation dose with preserved diagnostic quality

被引:29
作者
Bjorkdahl, Peter [1 ]
Nyman, Ulf [1 ]
机构
[1] Lund Univ, Dept Radiol, SE-23185 Lasarettet Trelleborg, Trelleborg, Sweden
关键词
LEAN BODY-MASS; CT ANGIOGRAPHY; IMAGE QUALITY; CONTRAST ENHANCEMENT; MULTIDETECTOR CT; PATIENT WEIGHT; KILOVOLTAGE; OPTIMIZATION; ATTENUATION; REDUCTION;
D O I
10.3109/02841850903505222
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare radiation dose and image quality in a chest phantom and in patients for the diagnosis of pulmonary embolism (PE) at 100 and 120 peak kilovoltage (kVp) using 16-multichannel detector computed tomography (MDCT). Material and Methods: A 20-ml syringe containing 12 mg I/ml was scanned in a chest phantom at 100/120 kVp and 25 milliampere seconds (mAs). Consecutive patients underwent 100 kVp (n = 50) and 120 kVp (n = 50) 16-MDCT using a "quality reference" effective mAs of 100, 300 mg I/kg, and a 12-s injection duration. Attenuation (CT number), image noise (1 standard deviation), and contrast-to-noise ratio (CNR; fresh clot = 70 HU) of the contrast medium syringe and pulmonary arteries were evaluated on 3-mm-thick slices. Subjective image quality was assessed. Computed tomography dose index (CTDIvol) and dose-length product (DLP) were presented by the CT software, and effective dose was estimated. Results: Mean values in the chest phantom and patients changed as follows when X-ray tube potential decreased from 120 to 100 kVp: attenuation +23% and +40%, noise +38% and +48%, CNR -6% and 0%, and CTDIvol-38% and -40%, respectively. Mean DLP and effective dose in the patients decreased by 42% and 45%, respectively. Subjective image quality was excellent or adequate in 49/48 patients at 100/120 kVp. No patient with a negative CT had any thromboembolism diagnosed during 3-month follow-up. Conclusion: By reducing X-ray tube potential from 120 to 100 kVp, while keeping all other scanning parameters unchanged, the radiation dose to the patient may be almost halved without deterioration of diagnostic quality, which may be of particular benefit in young individuals.
引用
收藏
页码:260 / 270
页数:11
相关论文
共 41 条
[1]   Computed tomographic pulmonary angiography vs ventilation-perfusion lung scanning in patients with suspected pulmonary embolism - A Randomized controlled trial [J].
Anderson, David R. ;
Kahn, Susan R. ;
Rodger, Marc A. ;
Kovacs, Michael J. ;
Morris, Tim ;
Hirsch, Andrew ;
Lang, Eddy ;
Stiell, Ian ;
Kovacs, George ;
Dreyer, Jon ;
Dennie, Carol ;
Cartier, Yannick ;
Barnes, David ;
Burton, Erica ;
Pleasance, Susan ;
Skedgel, Chris ;
O'Rouke, Keith ;
Wells, Philip S. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2007, 298 (23) :2743-2753
[2]   Effect of contrast material injection duration and rate on aortic peak time and peak enhancement at dynamic CT involving injection protocol with dose tailored to patient weight [J].
Awai, K ;
Hiraishi, K ;
Hori, S .
RADIOLOGY, 2004, 230 (01) :142-150
[3]   Scan and contrast administration principles of MDCT [J].
Bae, KT ;
Heiken, JP .
EUROPEAN RADIOLOGY, 2005, 15 :E46-E59
[4]   Aortic and hepatic contrast medium enhancement at CT part II. Effect of reduced cardiac output in a porcine model [J].
Bae, KT ;
Heiken, JP ;
Brink, JA .
RADIOLOGY, 1998, 207 (03) :657-662
[5]   Effect of patient weight and scanning duration on contrast enhancement during pulmonary multidetector CT angiography [J].
Bae, Kyongtae T. ;
Tao, Cheng ;
Gurel, Safiye ;
Hong, Cheng ;
Zhu, Fang ;
Gebke, Todd A. ;
Milite, Margherita ;
Hildebolt, Charles F. .
RADIOLOGY, 2007, 242 (02) :582-589
[6]   Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[7]   Error in radiology [J].
Fitzgerald, R .
CLINICAL RADIOLOGY, 2001, 56 (12) :938-946
[8]   Quantitative assessment of selective in-plane shielding of tissues in computed tomography through evaluation of absorbed dose and image quality [J].
Geleijns, J. ;
Salvado Artells, M. ;
Veldkamp, W. J. H. ;
Lopez Tortosa, M. ;
Calzado Cantera, A. .
EUROPEAN RADIOLOGY, 2006, 16 (10) :2334-2340
[9]   Image quality and radiation exposure at pulmonary CT angiography with 100-or 120-kVp protocol: prospective randomized study [J].
Heyer, Christoph M. ;
Mohr, Patrick S. ;
Lemburg, Stefan P. ;
Peters, Soeren A. ;
Nicolas, Volkmar .
RADIOLOGY, 2007, 245 (02) :577-583
[10]   Minimizing Contrast Medium Doses to Diagnose Pulmonary Embolism with 80-kVp Multidetector Computed Tomography in Azotemic Patients [J].
Holmquist, F. ;
Hansson, K. ;
Pasquariello, F. ;
Bjork, J. ;
Nyman, U. .
ACTA RADIOLOGICA, 2009, 50 (02) :181-193