Vacuum level effects on knee contact force for unilateral transtibial amputees with elevated vacuum suspension

被引:3
作者
Xu, Hang [1 ,2 ]
Greenland, Kasey [2 ]
Bloswick, Donald [2 ]
Zhao, Jie [1 ,3 ]
Merryweather, Andrew [2 ]
机构
[1] Xuzhou Med Univ, Sch Med Imaging, Xuzhou, Peoples R China
[2] Univ Utah, Dept Mech Engn, 1495 E 100 S, Salt Lake City, UT 84112 USA
[3] Natl Yang Ming Univ, Dept Biomed Imaging & Radiol Sci, Taipei, Taiwan
基金
中国国家自然科学基金;
关键词
Biomechanics; Amputees; Prosthesis; Vacuum level; Joint loading; INDIVIDUAL MUSCLE CONTRIBUTIONS; DYNAMIC SIMULATIONS; NORMAL WALKING; LOWER-EXTREMITY; GAIT; JOINT; OSTEOARTHRITIS; STRENGTH; LOADS; PREVALENCE;
D O I
10.1016/j.jbiomech.2017.04.013
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The elevated vacuum suspension system (EVSS) has demonstrated unique health benefits for amputees, but the effect of vacuum pressure values on knee contact force (KCF) is still unclear. The objective of this study was to investigate the effect of vacuum levels on KCF for unilateral transtibial amputees (UTA) using the EVSS. Three-dimensional gait was modeled for 9 UTA with five vacuum levels (0-20 inHg [67.73 kPa], 5 inHg [16.93 kPa] increments) and 9 non-amputees based on kinematic and ground reaction force data. The results showed that the vacuum level effects were significant for peak axial KCF, which had a relatively large value at 0 and 20 inHg (67.73 kPa). The intact limb exhibited a comparable peak axial KCF to the non-amputees at 15 inHg (50.79 kPa). At moderate vacuum levels (5 inHg [16.93 kPa] to 15 inHg [50.79 kPa]), co-contraction of quadriceps and hamstrings at peak axial KCF was similar for the intact limb, but was smaller for the residual limb comparing with the non-amputees. The intact limb showed a similar magnitude of quadriceps and hamstrings force at 15 inHg (50.79 kPa) to the non amputees, but the muscle coordination patterns varied between the residual and intact limbs. These findings indicate that a proper vacuum level may partially compensate for the lack of ankle plantarflexor and reduce the knee loading. Of the tested vacuum levels, 15 inHg (50.79 kPa) appears most favorable, although additional analyses with more amputees are suggested to confirm these results prior to establishing clinical guidelines. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:110 / 116
页数:7
相关论文
共 45 条
[1]   Individual muscle contributions to support in normal walking [J].
Anderson, FC ;
Pandy, MG .
GAIT & POSTURE, 2003, 17 (02) :159-169
[2]   MUSCULAR COACTIVATION - THE ROLE OF THE ANTAGONIST MUSCULATURE IN MAINTAINING KNEE STABILITY [J].
BARATTA, R ;
SOLOMONOW, M ;
ZHOU, BH ;
LETSON, D ;
CHUINARD, R ;
DAMBROSIA, R .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1988, 16 (02) :113-122
[3]   A comparison of trans-tibial amputee suction and vacuum socket conditions [J].
Board, WJ ;
Street, GM ;
Caspers, C .
PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2001, 25 (03) :202-209
[4]   OpenSim: open-source software to create and analyze dynamic Simulations of movement [J].
Delp, Scott L. ;
Anderson, Frank C. ;
Arnold, Allison S. ;
Loan, Peter ;
Habib, Ayman ;
John, Chand T. ;
Guendelman, Eran ;
Thelen, Darryl G. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2007, 54 (11) :1940-1950
[5]   Changes in In Vivo Knee Loading with a Variable-Stiffness Intervention Shoe Correlate with Changes in the Knee Adduction Moment [J].
Erhart, Jennifer C. ;
Dyrby, Chris O. ;
D'Lima, Darryl D. ;
Colwell, Clifford W. ;
Andriacchi, Thomas P. .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2010, 28 (12) :1548-1553
[6]   Grand challenge competition to predict in vivo knee loads [J].
Fregly, Benjamin J. ;
Besier, Thor F. ;
Lloyd, David G. ;
Delp, Scott L. ;
Banks, Scott A. ;
Pandy, Marcus G. ;
D'Lima, Darryl D. .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2012, 30 (04) :503-513
[7]   Review of secondary physical conditions associated with lower-limb amputation and long-term prosthesis use [J].
Gailey, Robert ;
Allen, Kerry ;
Castles, Julie ;
Kucharik, Jennifer ;
Roeder, Mariah .
JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2008, 45 (01) :15-29
[8]  
Gerschutz M, 2011, TECHNICAL NOTES ELEV
[9]  
Gerschutz MJ., 2010, J PROSTHET ORTHOT, V22, P252, DOI DOI 10.1097/JPO.0B013E3181F903DF
[10]   The three-dimensional determination of internal loads in the lower extremity [J].
Glitsch, U ;
Baumann, W .
JOURNAL OF BIOMECHANICS, 1997, 30 (11-12) :1123-1131