Effects of Guided Random Sampling of TCCs on Blood Flow Values in CT Perfusion Studies of Lung Tumors

被引:25
作者
Gibaldi, Agostino [1 ]
Barone, Domenico [2 ]
Gavelli, Giampaolo [2 ]
Malavasi, Silvia [1 ,3 ]
Bevilacqua, Alessandro [1 ,4 ]
机构
[1] Univ Bologna, Adv Res Ctr Elect Syst Informat & Commun Technol, I-40125 Bologna, Italy
[2] IRCSS Ist Sci Romagnolo Studio & Cura Tumori IRST, Radiol Unit, I-47014 Meldola, FC, Italy
[3] Univ Bologna, Dept Elect Elect & Informat Engn Guglielmo Marcon, Bologna, Italy
[4] Univ Bologna, Dept Comp Sci & Engn DISI, Bologna, Italy
关键词
CT perfusion; TCC; guided RANSAC; lung tumor; reliability; CONTRAST-ENHANCED CT; COMPUTED-TOMOGRAPHY; 1ST-PASS CT; CANCER; MODEL; VOLUME; MRI; PERMEABILITY; CONSENSUS; MLESAC;
D O I
10.1016/j.acra.2014.08.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: Tissue perfusion is commonly used to evaluate lung tumor lesions through dynamic contrast-enhanced computed tomography (DCE-CT). The aim of this study was to improve the reliability of the blood flow (BF) maps by means of a guided sampling of the tissue time-concentration curves (TCCs). Materials and Methods: Fourteen selected CT perfusion (CTp) examinations from different patients with lung lesions were considered, according to different degrees of motion compensation. For each examination, two regions of interest (ROIs) referring to the target lesion and the arterial input were manually segmented. To obtain the perfusion parameters, we computed the maximum slope of the Hill equation, describing the pharmacokinetics of the contrast agent, and the TCC was fitted for each voxel. A guided iterative approach based on the Random Sample Consensus method was used to detect and exclude samples arising from motion artifacts through the assessment of the confidence level of each single temporal sample of the TCC compared to the model. Removing these samples permits to refine the model fitting, thus exploiting more reliable data. Goodness-of-fit measures of the fitted TCCs to the original data (eg, root mean square error and correlation distance) were used to assess the reliability of the BF values, so as to preserve the functional structure of the resulting perfusion map. We devised a quantitative index, the local coefficient of variation (ICV), to measure the spatial coherence of perfusion maps, from local to regional and global resolution. The effectiveness of the algorithm was tested under three different degrees of motion yielded by as many alignment procedures. Results: At pixel level, the proposed approach improved the reliability of BF values, quantitatively assessed through the correlation index. At ROI level, a comparative analysis emphasized how our approach "replaced" the noisy pixels, providing smoother parametric maps while preserving the main functional structure. Moreover, the implemented algorithm provides a more meaningful effect in correspondence of a higher motion degree. This was confirmed both quantitatively, using the ICV, and qualitatively, through visual inspection by expert radiologists. Conclusions: Perfusion maps achieved with the proposed approach can now be used as a valid tool supporting radiologists in DCE-CTp studies. This represents a step forward to clinical utilization of these studies for staging, prognosis, and monitoring values of therapeutic regimens.
引用
收藏
页码:58 / 69
页数:12
相关论文
共 43 条
[1]  
Ahearn T, 2005, PHYS MED BIOL, V50, P307
[2]  
[Anonymous], 2010, Biostatistical Analysis
[3]   Mapping the Zonal Organization of Tumor Perfusion and Permeability in a Rat Glioma Model by Using Dynamic Contrast-enhanced Synchrotron Radiation CT [J].
Balvay, Daniel ;
Tropres, Irene ;
Billet, Romain ;
Joubert, Aurelie ;
Peoc'h, Michel ;
Cuenod, Charles A. ;
Le Duc, Geraldine .
RADIOLOGY, 2009, 250 (03) :692-702
[4]   Accuracy of gamma-variate fits to concentration-time curves from dynamic susceptibility-contrast enhanced MRI: Influence of time resolution, maximal signal drop and signal-to-noise [J].
Benner, T ;
Heiland, S ;
Erb, G ;
Forsting, M ;
Sartor, K .
MAGNETIC RESONANCE IMAGING, 1997, 15 (03) :307-317
[5]   Estimation of tissue perfusion by dynamic contrast-enhanced imaging: simulation-based evaluation of the steepest slope method [J].
Brix, Gunnar ;
Zwick, Stefan ;
Griebel, Juergen ;
Fink, Christian ;
Kiessling, Fabian .
EUROPEAN RADIOLOGY, 2010, 20 (09) :2166-2175
[6]  
Chan AA, 2004, 2004 2ND IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1 and 2, P1067
[7]   Semiautomated Motion Correction of Tumors in Lung CT-perfusion Studies [J].
Chandler, Adam ;
Wei, Wei ;
Herron, Delise H. ;
Anderson, Ella F. ;
Johnson, Valen E. ;
Ng, Chaan S. .
ACADEMIC RADIOLOGY, 2011, 18 (03) :286-293
[8]   Quantitative CT: technique dependence of volume estimation on pulmonary nodules [J].
Chen, Baiyu ;
Barnhart, Huiman ;
Richard, Samuel ;
Colsher, James ;
Amurao, Maxwell ;
Samei, Ehsan .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (05) :1335-1348
[9]   Matching with PROSAC - Progressive Sample Consensus [J].
Chum, O ;
Matas, J .
2005 IEEE COMPUTER SOCIETY CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION, VOL 1, PROCEEDINGS, 2005, :220-226
[10]   RANDOM SAMPLE CONSENSUS - A PARADIGM FOR MODEL-FITTING WITH APPLICATIONS TO IMAGE-ANALYSIS AND AUTOMATED CARTOGRAPHY [J].
FISCHLER, MA ;
BOLLES, RC .
COMMUNICATIONS OF THE ACM, 1981, 24 (06) :381-395