Evaluation of accuracy of B-spline transformation-based deformable image registration with different parameter settings for thoracic images

被引:34
作者
Kanai, Takayuki [1 ]
Kadoya, Noriyuki [1 ]
Ito, Kengo [1 ]
Onozato, Yusuke [1 ]
Cho, Sang Yong [1 ]
Kishi, Kazuma [2 ]
Dobashi, Suguru [3 ]
Umezawa, Rei [1 ]
Matsushita, Haruo [1 ]
Takeda, Ken [3 ]
Jingu, Keiichi [1 ]
机构
[1] Tohoku Univ, Sch Med, Dept Radiat Oncol, Aoba Ku, Sendai, Miyagi 9808574, Japan
[2] Tohoku Univ Hosp, Aoba Ku, Sendai, Miyagi, Japan
[3] Tohoku Univ, Fac Med, Sch Hlth Sci, Dept Radiol Technol,Aoba Ku, Sendai, Miyagi 9808574, Japan
关键词
deformable image registration; adaptive radiotherapy; 4DCT; lung; COMPUTED-TOMOGRAPHY; VENTILATION; CT; RADIOTHERAPY; ALGORITHMS; IMPACT;
D O I
10.1093/jrr/rru062
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Deformable image registration (DIR) is fundamental technique for adaptive radiotherapy and image-guided radiotherapy. However, further improvement of DIR is still needed. We evaluated the accuracy of B-spline transformation-based DIR implemented in elastix. This registration package is largely based on the Insight Segmentation and Registration Toolkit (ITK), and several new functions were implemented to achieve high DIR accuracy. The purpose of this study was to clarify whether new functions implemented in elastix are useful for improving DIR accuracy. Thoracic 4D computed tomography images of ten patients with esophageal or lung cancer were studied. Datasets for these patients were provided by DIR-lab (dir-lab.com) and included a coordinate list of anatomical landmarks that had been manually identified. DIR between peak-inhale and peak-exhale images was performed with four types of parameter settings. The first one represents original ITK (Parameter 1). The second employs the new function of elastix (Parameter 2), and the third was created to verify whether new functions improve DIR accuracy while keeping computational time (Parameter 3). The last one partially employs a new function (Parameter 4). Registration errors for these parameter settings were calculated using the manually determined landmark pairs. 3D registration errors with standard deviation over all cases were 1.78 (1.57), 1.28 (1.10), 1.44 (1.09) and 1.36 (1.35) mm for Parameter 1, 2, 3 and 4, respectively, indicating that the new functions are useful for improving DIR accuracy, even while maintaining the computational time, and this B-spline-based DIR could be used clinically to achieve high-accuracy adaptive radiotherapy.
引用
收藏
页码:1163 / 1170
页数:8
相关论文
共 34 条
  • [31] Four-dimensional computed tomography pulmonary ventilation images vary with deformable image registration algorithms and metrics
    Yamamoto, Tokihiro
    Kabus, Sven
    Klinder, Tobias
    von Berg, Jens
    Lorenz, Cristian
    Loo, Billy W., Jr.
    Keall, Paul J.
    [J]. MEDICAL PHYSICS, 2011, 38 (03) : 1348 - 1358
  • [32] IMPACT OF FOUR-DIMENSIONAL COMPUTED TOMOGRAPHY PULMONARY VENTILATION IMAGING-BASED FUNCTIONAL AVOIDANCE FOR LUNG CANCER RADIOTHERAPY
    Yamamoto, Tokihiro
    Kabus, Sven
    von Berg, Jens
    Lorenz, Cristian
    Keall, Paul J.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 79 (01): : 279 - 288
  • [33] The impact of audio-visual biofeedback on 4D PET images: Results of a phantom study
    Yang, Jaewon
    Yamamoto, Tokihiro
    Cho, Byungchul
    Seo, Youngho
    Keall, Paul J.
    [J]. MEDICAL PHYSICS, 2012, 39 (02) : 1046 - 1057
  • [34] Modeling respiratory motion for reducing motion artifacts in 4D CT images
    Zhang, Yongbin
    Yang, Jinzhong
    Zhang, Lifei
    Court, Laurence E.
    Balter, Peter A.
    Dong, Lei
    [J]. MEDICAL PHYSICS, 2013, 40 (04)