Geometry planning and image registration in magnetic particle imaging using bimodal fiducial markers

被引:12
|
作者
Werner, F. [1 ,2 ]
Jung, C. [3 ]
Hofmann, M. [1 ,2 ]
Werner, R. [4 ]
Salamon, J. [3 ]
Saering, D. [4 ]
Kaul, M. G. [3 ]
Them, K. [1 ,2 ]
Weber, O. M. [5 ]
Mummert, T. [3 ]
Adam, G. [3 ]
Ittrich, H. [3 ]
Knopp, T. [1 ,2 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Sect Biomed Imaging, D-20246 Hamburg, Germany
[2] Hamburg Univ Technol, Inst Biomed Imaging, D-21073 Hamburg, Germany
[3] Univ Med Ctr Hamburg Eppendorf, Dept Diagnost & Intervent Radiol, D-20246 Hamburg, Germany
[4] Univ Med Ctr Hamburg Eppendorf, Inst Computat Neurosci, D-20246 Hamburg, Germany
[5] Philips Med Syst DMC GmbH, D-22335 Hamburg, Germany
关键词
registration; MPI; MRI; fiducialmarker; geometry planning; RECONSTRUCTION; RESOLUTION;
D O I
10.1118/1.4948998
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Magnetic particle imaging (MPI) is a quantitative imaging modality that allows the distribution of superparamagnetic nanoparticles to be visualized. Compared to other imaging techniques like x-ray radiography, computed tomography (CT), and magnetic resonance imaging (MRI), MPI only provides a signal from the administered tracer, but no additional morphological information, which complicates geometry planning and the interpretation of MP images. The purpose of the authors' study was to develop bimodal fiducial markers that can be visualized by MPI and MRI in order to create MP-MR fusion images. Methods: A certain arrangement of three bimodal fiducial markers was developed and used in a combined MRI/MPI phantom and also during in vivo experiments in order to investigate its suitability for geometry planning and image fusion. An algorithm for automated marker extraction in both MR and MP images and rigid registration was established. Results: The developed bimodal fiducial markers can be visualized by MRI and MPI and allow for geometry planning as well as automated registration and fusion of MR-MP images. Conclusions: To date, exact positioning of the object to be imaged within the field of view (FOV) and the assignment of reconstructed MPI signals to corresponding morphological regions has been difficult. The developed bimodal fiducial markers and the automated image registration algorithm help to overcome these difficulties. (C) 2016 American Association of Physicists in Medicine.
引用
收藏
页码:2884 / 2893
页数:10
相关论文
共 50 条
  • [1] MRI/PET nonrigid breast-image registration using skin fiducial markers
    Krol, Andrzej
    Unlu, Mehmet Z.
    Baum, Karl G.
    Mandel, James A.
    Lee, Wei
    Coman, Ioana L.
    Lipson, Edward D.
    Feiglin, David H.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2006, 21 : 39 - 43
  • [2] Magnetic resonance imaging in the radiation treatment planning of localized prostate cancer using intra-prostatic fiducial markers for computed tomography co-registration
    Parker, CC
    Damyanovich, A
    Haycocks, T
    Haider, M
    Bayley, A
    Catton, CN
    RADIOTHERAPY AND ONCOLOGY, 2003, 66 (02) : 217 - 224
  • [3] Comparison of different fiducial markers to guide SPECT and CT image registration
    Zanetti, T. C.
    Brunetto, S. Q.
    Souza, E. M.
    Sachinelli, L. D. S.
    Ramos, C. D.
    Zantut-Wittmann, D. E.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (05)
  • [4] Fiducial registration error as a statistical process control metric in image-guidance radiotherapy with fiducial markers
    Ung, N. M.
    Wee, L.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (23): : 7473 - 7485
  • [5] Improving the accuracy of prostate delineation by registration of fiducial markers on planning CT and ultrasound
    Westendorp, R.
    van 't Riet, A.
    Hoekstra, C.
    Immerzeel, J.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S499 - S499
  • [6] Bimodal Interventional Instrument Markers for Magnetic Particle Imaging and Magnetic Resonance Imaging-A Proof-of-Concept Study
    Wegner, Franz
    Luedtke-Buzug, Kerstin
    Cremers, Sjef
    Friedrich, Thomas
    Sieren, Malte M.
    Haegele, Julian
    Koch, Martin A.
    Saritas, Emine U.
    Borm, Paul
    Buzug, Thorsten M.
    Barkhausen, Joerg
    Ahlborg, Mandy
    NANOMATERIALS, 2022, 12 (10)
  • [7] Registration of MR and SPECT without using external fiducial markers
    de Munck, JC
    Verster, FC
    Dubois, EA
    Habraken, JBA
    Boltjes, B
    Claus, JJ
    van Herk, M
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (05): : 1255 - 1269
  • [8] Registration of head volume images using implantable fiducial markers
    Maurer, CR
    Fitzpatrick, JM
    Wang, MY
    Galloway, RL
    Maciunas, RJ
    Allen, GS
    IMAGE PROCESSING - MEDICAL IMAGING 1997, PTS 1 AND 2, 1997, 3034 : 561 - 579
  • [9] Registration of head volume images using implantable fiducial markers
    Maurer, CR
    Fitzpatrick, JM
    Wang, MY
    Galloway, RL
    Maciunas, RJ
    Allen, GS
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (04) : 447 - 462
  • [10] Development of external fiducial markers for image registration in small animal SPECT/CT
    Sakdinawat, AE
    Iwata, K
    Hwang, AB
    Tang, HR
    Wong, KH
    Hasegawa, BH
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 842 - 845