Reactivities of organic phase biosensors. 2. The amperometric behaviour of horseradish peroxidase immobilised on a platinum electrode modified with an electrosynthetic polyaniline film

被引:101
作者
Iwuoha, EI
de Villaverde, DS
Garcia, NP
Smyth, MR [1 ]
Pingarron, JM
机构
[1] Dublin City Univ, Sch Chem Sci, Biomed & Environm Sensor Technol Ctr, Dublin 9, Ireland
[2] Univ Complutense Madrid, Dept Quim Analit, E-28040 Madrid, Spain
关键词
polyaniline based biosensor; organic phase biosensor; organic phase enzyme electrode; peroxide sensor; polyaniline film doped with poly(vinylsulphonate); kinetics of organic phase horseradish peroxidase electrode;
D O I
10.1016/S0956-5663(97)00042-0
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An amperometric peroxide biosensor was prepared by electrochemical deposition of horseradish peroxidase (HRP) on a Pt disc electrode modified with polyaniline (PANI) film doped with polyvinyl sulphonate (PVS). Electrochemical characterisation of the PANI-PVS film (without HRP) indicates a conducting electroactive polymer that exhibits fast reversible electrochemistry in 1M HCl. The HRP-based sensor was stable and gave rise to reproducible steady state responses for up to two weeks, when operated as both organic phase and aqueous phase H(2)O(2) biosensors at -100 mV/Ag-AgCl and 25 degrees C. The aqueous phase for the H(2)O(2) assay was 0.05 M phosphate buffer, pH 6.88, while acetone, acetonitrile, propan-2-ol and tetrahydrofuran (THF) organic phases were used. The analyses of the calibration curves of the biosensor showed that the system followed a Michaelis-Menten kinetics when operated either as organic- or aqueous-phase biosensors. The kinetic parameters K(m)' (apparent Michaelis Menten constant), k(cat)' (apparent biosensor turnover rate constant), and k(cat)'/K(m)' biosensing efficiency parameter) were evaluated from the steady-state amperometric data obtained in the five solvent media. The values of the biosensor efficiency factor, k(cat)'/K(m)', show that the sensor exhibits greater efficiency for analyte detection when operated in organic-phase mode in acetonitrile medium than in aqueous buffer. (C) 1997 Elsevier Science Limited.
引用
收藏
页码:749 / 761
页数:13
相关论文
共 45 条
[1]   Conducting polymers and the bioanalytical sciences: New tools for biomolecular communications - A review [J].
Adeloju, SB ;
Wallace, GG .
ANALYST, 1996, 121 (06) :699-703
[2]   KINETIC CHARACTERIZATION OF THE EFFECTS OF ORGANIC-SOLVENTS ON THE PERFORMANCE OF A PEROXIDASE-MODIFIED ELECTRODE IN DETECTING PEROXIDES, THIOUREA AND ETHYLENETHIOUREA [J].
ADEYOJU, O ;
IWUOHA, EI ;
SMYTH, MR .
ELECTROANALYSIS, 1995, 7 (10) :924-929
[3]   DETERMINATION OF KINETIC-PARAMETERS FR THE INHIBITORY EFFECTS OF ORGANIC SULFIDES ON AN AMPEROMETRIC PEROXIDE BIOSENSOR IN NONAQUEOUS MEDIA [J].
ADEYOJU, O ;
IWUOHA, EI ;
SMYTH, MR .
TALANTA, 1994, 41 (09) :1603-1608
[4]   REACTIVITIES OF AMPEROMETRIC ORGANIC-PHASE PEROXIDASE-MODIFIED ELECTRODES IN THE PRESENCE AND ABSENCE OF THIOUREA AND ETHYLENETHIOUREA AS INHIBITORS [J].
ADEYOJU, O ;
IWUOHA, EI ;
SMYTH, MR .
ANALYTICA CHIMICA ACTA, 1995, 305 (1-3) :57-64
[5]  
[Anonymous], CHEM KINETICS STUDY
[6]   COMPARATIVE-STUDY OF THE ION-EXCHANGE AND ELECTROCHEMICAL PROPERTIES OF SULFONATED POLYANILINE (SPAN) AND POLYANILINE (PANI) [J].
BARBERO, C ;
MIRAS, MC ;
KOTZ, R ;
HAAS, O .
SYNTHETIC METALS, 1993, 55 (2-3) :1539-1544
[7]   A microelectrochemical switch responsive to NADH [J].
Bartlett, PN ;
Wang, JH ;
Wallace, ENK .
CHEMICAL COMMUNICATIONS, 1996, (03) :359-360
[8]   THEORETICAL TREATMENT OF DIFFUSION AND KINETICS IN AMPEROMETRIC IMMOBILIZED ENZYME ELECTRODES .1. REDOX MEDIATOR ENTRAPPED WITHIN THE FILM [J].
BARTLETT, PN ;
PRATT, KFE .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 397 (1-2) :61-78
[9]  
BARTLETT PN, 1993, J ELECTROANAL CHEM, V262, P1
[10]   CYCLIC AND DIFFERENTIAL PULSE VOLTAMMETRIC BEHAVIOR OF REACTANTS CONFINED TO ELECTRODE SURFACE [J].
BROWN, AP ;
ANSON, FC .