Determination of nitrite in water samples by sequential injection analysis with chemiluminescence detection on chip flow cell

被引:0
作者
Wang, Y [1 ]
Fan, SH [1 ]
机构
[1] Northeastern Univ, Res Ctr Anal Sci, Shenyang 110004, Peoples R China
关键词
microchip flow cell; sequential injection; chemiluminescence; nitrite;
D O I
暂无
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A sequential injection chemiluminescence's system using a chip flow cell was described for the determination of trace amount of nitrite in water samples. Nitride reacted with hydrogen peroxide to form peroxynitrous acid in sulfuric acid medium, which was an unstable in acid medium and subsequently was quenched into peroxynitrite in basic solution. During the composition of peroxynitrite the chemiluminescence intensity was enhanced with the presence of uranin and ethyldimethylcetylammonium bromide. The reaction coil (flow cell) and holding coil was combined for tracking the emission signal. The experimental parameters including physical and chemical parameter were optimized. The interference of cations in water samples was eliminated by passing previously the sample solution trough a cation-exchange column. The linear range of the calibration graph was obtained from 1 X 10(-6) to 1 X 10(-4) mol.L-1 with a correlation coefficient of 0.999 8. The detection limit at 95% confidence was 6.8 X 10(-7) mol.L-1. The relative standard deviation at 1 X 10(-5) mol.L-1 nitrite level was 2.7 %, and the recovery of 90 %-99 % and the sampling frequency of 80 h(-1) were obtained.
引用
收藏
页码:184 / 187
页数:4
相关论文
共 16 条
[1]  
AOKI T, 1997, FLOW INJECTION ANAL, V14, P47
[2]  
Bateman RM, 2002, CLIN CHEM, V48, P570
[3]   Chemiluminescence detection for hybridization assays on the flow-thru chip, a three-dimensional microchannel biochip [J].
Cheek, BJ ;
Steel, AB ;
Torres, MP ;
Yu, YY ;
Yang, HJ .
ANALYTICAL CHEMISTRY, 2001, 73 (24) :5777-5783
[4]   GAS-CHROMATOGRAPHIC DETERMINATION OF NITRITE ION IN WATER USING THE SANDMEYER REACTION [J].
CHIKAMOTO, T ;
NAGATA, S .
CHEMISTRY LETTERS, 1980, (06) :737-738
[5]   CHARACTERIZATION AND REDUCTION OF INTERFERENCES IN FLOW-INJECTION ANALYSIS FOR THE IN-SITU DETERMINATION OF NITRATE AND NITRITE IN SEA-WATER [J].
DANIEL, A ;
BIROT, D ;
LEHAITRE, M ;
PONCIN, J .
ANALYTICA CHIMICA ACTA, 1995, 308 (1-3) :413-424
[6]  
FANG ZL, 2003, MICROFLUID ANAL CHIP
[7]   Flow-injection analysis spectrophotometric determination of nitrite and nitrate in water samples by reaction with proflavin [J].
Guerrero, RS ;
Benito, CG ;
Calatayud, JM .
TALANTA, 1996, 43 (02) :239-246
[8]   Report on interlaboratory testing for the determination of nitrite and nitrate in river-water samples by flow-injection analysis [J].
Higuchi, K ;
Goto, R ;
Kawashima, T ;
Oguma, K ;
Kawase, A ;
Ogura, H .
BUNSEKI KAGAKU, 2000, 49 (01) :35-42
[9]   Capillary electrophoresis system with flow injection sample introduction and chemiluminescence detection on a chip platform [J].
Huang, XJ ;
Pu, QS ;
Fang, ZL .
ANALYST, 2001, 126 (03) :281-284
[10]   Gas chromatographic determination of nitrite in water by precolumn formation of 2-phenylphenol with flame ionization detection [J].
Jain, A ;
Smith, RM ;
Verma, KK .
JOURNAL OF CHROMATOGRAPHY A, 1997, 760 (02) :319-325