Sensitivity and False Alarm Rate of a Fall Sensor in Long-Term Fall Detection in the Elderly

被引:42
作者
Kangas, Maarit [1 ,3 ]
Korpelainen, Raija [1 ,2 ,3 ,4 ]
Vikman, Irene [5 ]
Nyberg, Lars [5 ]
Jamsa, Timo [1 ,3 ]
机构
[1] Univ Oulu, Dept Med Technol, Inst Biomed, Oulu Univ Hosp, FI-90014 Oulu, Finland
[2] Univ Oulu, Inst Hlth Sci, Oulu Univ Hosp, FI-90014 Oulu, Finland
[3] Univ Oulu, Med Res Ctr Oulu, Oulu Univ Hosp, FI-90014 Oulu, Finland
[4] Oulu Deaconess Inst, Dept Sports & Exercise Med, Oulu, Finland
[5] Lulea Univ Technol, Dept Hlth Sci, S-95187 Lulea, Sweden
基金
芬兰科学院;
关键词
Accelerometer; Fall detector; Specificity; Older people; Frequent faller; TRIAXIAL ACCELEROMETER; RISK-FACTORS; OLDER-PEOPLE; LIFE; POPULATION; ALGORITHMS; TIME;
D O I
10.1159/000362720
中图分类号
R592 [老年病学]; C [社会科学总论];
学科分类号
03 ; 0303 ; 100203 ;
摘要
Background: About a third of home-dwelling older people fall each year, and institutionalized older people even report a two-or threefold higher rate for falling. Automatic fall detection systems have been developed to support the independent and secure living of the elderly. Even though good fall detection sensitivity and specificity in laboratory settings have been reported, knowledge about the sensitivity and specificity of these systems in real-life conditions is still lacking. Objective: The aim of this study was to evaluate the long-term fall detection sensitivity and false alarm rate of a fall detection prototype in real-life use. Methods: A total of 15,500 h of real-life data from 16 older people, including both fallers and nonfallers, were monitored using an accelerometry- based sensor system with an implemented fall detection algorithm. Results: The fall detection system detected 12 out of 15 real-life falls, having a sensitivity of 80.0%, with a false alarm rate of 0.049 alarms per usage hour with the implemented real-time system. With minor modification of data analysis the false alarm rate was reduced to 0.025 false alarms per hour, equating to 1 false fall alarm per 40 usage hours. Conclusion: These data suggest that automatic accelerometric fall detection systems might offer a tool for improving safety among older people. (C) 2014 S. Karger AG, Basel
引用
收藏
页码:61 / 68
页数:8
相关论文
共 36 条
[1]  
Becker C, 2012, Z GERONTOL GERIATR, V45, P707, DOI 10.1007/s00391-012-0403-6
[2]   Accelerometer-based fall detection using optimized ZigBee data streaming [J].
Benocci, Marco ;
Tacconi, Carlo ;
Farella, Elisabetta ;
Benini, Luca ;
Chiari, Lorenzo ;
Vanzago, Laura .
MICROELECTRONICS JOURNAL, 2010, 41 (11) :703-710
[3]  
Bloch F., 2011, Annals of Physical and Rehabilitation Medicine, V54, P391, DOI 10.1016/j.rehab.2011.07.962
[4]   Evaluation of a threshold-based tri-axial accelerometer fall detection algorithm [J].
Bourke, A. K. ;
O'Brien, J. V. ;
Lyons, G. M. .
GAIT & POSTURE, 2007, 26 (02) :194-199
[5]   Evaluation of waist-mounted tri-axial accelerometer based fall-detection algorithms during scripted and continuous unscripted activities [J].
Bourke, A. K. ;
van de Ven, P. ;
Gamble, M. ;
O'Connor, R. ;
Murphy, K. ;
Bogan, E. ;
McQuade, E. ;
Finucane, P. ;
OLaighin, G. ;
Nelson, J. .
JOURNAL OF BIOMECHANICS, 2010, 43 (15) :3051-3057
[6]   TESTING OF A LONG-TERM FALL DETECTION SYSTEM INCORPORATED INTO A CUSTOM VEST FOR THE ELDERLY. [J].
Bourke, Alan K. ;
van de Ven, Pepijn W. J. ;
Chaya, Amy E. ;
OLaighin, Gearoid M. ;
Nelson, John .
2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, :2844-+
[7]   Risk factors in falls among the elderly according to extrinsic and intrinsic precipitating causes [J].
Bueno-Cavanillas, A ;
Padilla-Ruiz, F ;
Jiménez-Moleón, JJ ;
Peinado-Alonso, CA ;
Gálvez-Vargas, R .
EUROPEAN JOURNAL OF EPIDEMIOLOGY, 2000, 16 (09) :849-859
[8]   CIRCUMSTANCES AND CONSEQUENCES OF FALLS EXPERIENCED BY A COMMUNITY POPULATION 70 YEARS AND OVER DURING A PROSPECTIVE-STUDY [J].
CAMPBELL, AJ ;
BORRIE, MJ ;
SPEARS, GF ;
JACKSON, SL ;
BROWN, JS ;
FITZGERALD, JL .
AGE AND AGEING, 1990, 19 (02) :136-141
[9]   A comparison of automatic fall detection by the cross-product and magnitude of tri-axial acceleration [J].
Chao, Pei-Kuang ;
Chan, Hsiao-Lung ;
Tang, Fuk-Tan ;
Chen, Yu-Chuan ;
Wong, May-Kuen .
PHYSIOLOGICAL MEASUREMENT, 2009, 30 (10) :1027-1037
[10]   A Biomechanical Analysis of Ventral Furrow Formation in the Drosophila Melanogaster Embryo [J].
Conte, Vito ;
Ulrich, Florian ;
Baum, Buzz ;
Munoz, Jose ;
Veldhuis, Jim ;
Brodland, Wayne ;
Miodownik, Mark .
PLOS ONE, 2012, 7 (04)