Studies on the stripping voltammetric determination and speciation of chromium at a rotating-disc bismuth film electrode

被引:69
作者
Jorge, E. O. [1 ]
Rocha, M. M. [2 ]
Fonseca, I. T. E. [2 ]
Neto, M. M. M. [1 ,2 ]
机构
[1] Univ Tecn Lisboa, Inst Super Agron, Unidade Invest Quim Ambiental, P-1349017 Lisbon, Portugal
[2] Univ Lisbon, Fac Ciencias, Dept Quim & Bioquim, CCMM, P-1749016 Lisbon, Portugal
关键词
Chromium determination; Rotating-disc bismuth film electrode; Square wave adsorptive cathodic stripping voltammetry; Chromium speciation; ATOMIC-ABSORPTION-SPECTROMETRY; TRACE CHROMIUM; OPTIMIZATION PROCEDURE; CARBON ELECTRODES; AQUEOUS-SOLUTIONS; RIVER WATER; CR(VI); DTPA; COMPLEXATION; ADSORPTION;
D O I
10.1016/j.talanta.2009.12.043
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An adsorptive stripping voltammetric protocol coupled with a rotating-disc bismuth film electrode for the determination and speciation of chromium (III) and chromium (VI) in the presence of diethylenetriaminepentaacetic acid (DTPA) is presented. The developed methodology involves a mass-transport controlled preconcentration step, during which a Cr(III)-DTPA complex is adsorbed onto a pre-plated rotating-disc bismuth film electrode held at -0.4V, followed by a reductive square wave stripping scan. At -1.07V vs. Ag/AgCl, a peak is recorded due to the catalytic reduction of Cr(III)-DTPA to Cr(II)-DTPA. As a result of different chemical behaviours of Cr(III) and Cr(VI) in the presence of DTPA, the corresponding voltammetric signals presented different stabilities in time. A univariate optimization study was performed with several experimental parameters as variables. For Cr(VI) and total chromium, Cr(III) + Cr(VI), an accumulation time of 60 s at -0.4 V vs. Ag/AgCl resulted in detection limits of 0.336 and 0.414 nM and quantification limits of 1.12 and 1.40 nM, respectively. The relative standard deviation for 10 measurements of 5.0 nM chromate was 2.4%. Interference of other electroactive trace metals and surfactants was considered. A simple speciation scheme was proposed and satisfactorily applied to Cr(III) and Cr(VI) determinations in river water samples. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:556 / 564
页数:9
相关论文
共 52 条
[1]  
AITIO A, 1991, CARCINOGENICITY NICK, P168
[2]  
ALBERY WJ, 1971, RING DISK ELECTRODES, P16
[3]  
[Anonymous], 1993, Guidance for Drinking Water Quality, Recommendations, V1, P45
[4]  
Bobrowski A, 2000, ELECTROANAL, V12, P1177, DOI 10.1002/1521-4109(200010)12:15<1177::AID-ELAN1177>3.0.CO
[5]  
2-U
[6]   Chromium speciation study in polluted waters using catalytic adsorptive stripping voltammetry and tangential flow filtration [J].
Bobrowski, A ;
Bas, B ;
Dominik, J ;
Niewiara, E ;
Szalinska, E ;
Vignati, D ;
Zarebski, J .
TALANTA, 2004, 63 (04) :1003-1012
[7]   Characteristics of Voltammetric Determination and Speciation of Chromium - A Review [J].
Bobrowski, Andrzej ;
Krolicka, Agnieszka ;
Zarebski, Jerzy .
ELECTROANALYSIS, 2009, 21 (13) :1449-1458
[8]   THE DETERMINATION OF THE CHROMIUM SPECIATION IN SEA-WATER USING CATALYTIC CATHODIC STRIPPING VOLTAMMETRY [J].
BOUSSEMART, M ;
VAN DEN BERG, CMG ;
GHADDAF, M .
ANALYTICA CHIMICA ACTA, 1992, 262 (01) :103-115
[9]   Determination of chromium(VI) by batch injection analysis and adsorptive stripping voltammetry [J].
Brett, CMA ;
Filipe, OMS ;
Neves, CS .
ANALYTICAL LETTERS, 2003, 36 (05) :955-969
[10]   Electrochemical deposition of sol-gel films for enhanced chromium(VI) determination in aqueous solutions [J].
Carrington, Nathan A. ;
Yong, Li ;
Xue, Zi-Ling .
ANALYTICA CHIMICA ACTA, 2006, 572 (01) :17-24