Ultrasensitive "signal-on" sandwich electrochemiluminescence immunosensor based on Pd@Au-L-cysteine enabled multiple-amplification strategy for Apolipoprotein-A1 detection

被引:8
作者
Qi, Jilan [1 ]
Zhang, Xiaolei [1 ]
Zhang, Qiangyan [1 ]
Xue, Ying [1 ]
Meng, Fei [1 ]
Liu, Yuanhua [2 ]
Yang, Gongjun [1 ]
机构
[1] China Pharmaceut Univ, Minist Educ, Sch Pharm, Key Lab Drug Qual Control & Pharmacovigilance, Nanjing 210009, Peoples R China
[2] Nanjing Med Univ, Affiliated Canc Hosp, Canc Inst Jiangsu Prov, Dept Chemotherapy, 42 Baiziting Raod, Nanjing 210009, Peoples R China
关键词
Electrochemiluminescence immunosensor; Apolipoprotein-A1; Zinc oxalate metal organic frameworks; L-cysteine; Pd@Au core-shell nanostructure; BLADDER-CANCER BIOMARKER; GRAPHENE OXIDE; IMMUNOASSAY; APO-A1; RU(BPY)(3)(2+); PLATFORM; COMPLEX;
D O I
10.1016/j.microc.2022.107409
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, a "signal on" electrochemiluminescence (ECL) strategy was proposed to detect Apolipoprotein-A1 (Apo-A1), a common tumor biomarker for bladder cancer. The tris(2,2 '-bipyridyl)-ruthenium(II) [Ru(bpy)32+] was used as luminophor captured by three-dimensional (3D) zinc oxalate metal-organic frameworks (MOFs), which constructed as the ECL nanoprobe (Ru-MOF) for detecting Apo-A1. Meanwhile, L-cysteine (L-Cys) as the co-reactant was connected to the Pd@Au core-shell nanostructure through Au-S bond, which was directly modified on the glassy carbon electrode (GCE) to significantly reduce the electron transfer distance between the luminophor and co-reactant. The ECL intensity was "signal on" when the ECL probe of Ru-MOF was linked to the electrode by the immunoreaction of antigen-antibody. Based on these principles, the quantitative relationship between the concentration of Apo-A1 and the ECL intensity was obtained in the range of 1.00 fg center dot mL-1 to 1.00 ng center dot mL-1 with a linear coefficient of 0.9968. The proposed ECL immunosensor showed some great advantages, such as simplification, rapidity, stability and selectivity. It was also successfully applied for the determination of Apo-A1 in real serum and urine samples with the recovery of 98.0% ~ 115.0% (RSD < 5.2%). To sum up, a "signal on" ECL immunosensor was successfully constructed for Apo-A1 detection, and it may facilitate the diagnosis of bladder cancer in clinic.
引用
收藏
页数:10
相关论文
共 38 条
  • [11] A simple electrochemical immunosensor platform for detection of Apolipoprotein A1 (Apo-A1) as a bladder cancer biomarker in urine
    Kim, Seong-Eun
    Kim, Young Joo
    Song, Sunga
    Lee, Kook-Nyung
    Seong, Woo Kyeong
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2019, 278 : 103 - 109
  • [12] An organic red-emitting diode with a water-soluble DNA-polyaniline complex containing Ru(bpy)32+
    Kobayashi, N
    Uemura, S
    Kusabuka, K
    Nakahira, T
    Takahashi, H
    [J]. JOURNAL OF MATERIALS CHEMISTRY, 2001, 11 (07) : 1766 - 1768
  • [13] Li Chang-ying, 2013, Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi, V31, P266
  • [14] Discovery of Apo-A1 as a potential bladder cancer biomarker by urine proteomics and analysis
    Li, Changying
    Li, Hongjie
    Zhang, Ting
    Li, Jianmin
    Liu, Lingling
    Chang, Jiwu
    [J]. BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2014, 446 (04) : 1047 - 1052
  • [15] Electroactive metal-organic framework composites: Design and biosensing application
    Liao, Xianjiu
    Fu, Haomin
    Yan, Tingting
    Lei, Jianping
    [J]. BIOSENSORS & BIOELECTRONICS, 2019, 146
  • [16] An enzyme-free electrochemiluminescence biosensor for ultrasensitive assay of Group B Streptococci based on self-enhanced luminol complex functionalized CuMn-CeO2 nanospheres
    Ling, Jiaji
    Zhao, Min
    Chen, Fengjiao
    Zhou, Xiaoyan
    Li, Xiaosong
    Ding, Shijia
    Tang, Hua
    [J]. BIOSENSORS & BIOELECTRONICS, 2019, 127 : 167 - 173
  • [17] Highly sensitive electrochemiluminescence aptasensor based on a g-C3N4-COOH/ZnSe nanocomposite for kanamycin detection
    Liu, Xing-Pei
    Cheng, Jin-Long
    Mao, Chang-Jie
    Wu, Ming-Zai
    Chen, Jing-Shuai
    Jin, Bao- Kang
    [J]. MICROCHEMICAL JOURNAL, 2022, 172
  • [18] A sensitive electrochemiluminescence immunosensor based on luminophore capped Pd@Au core-shell nanoparticles as signal tracers and ferrocenyl compounds as signal enhancers
    Liu, Yuting
    Wang, Haijun
    Xiong, Chengyi
    Yuan, Yali
    Chai, Yaqin
    Yuan, Ruo
    [J]. BIOSENSORS & BIOELECTRONICS, 2016, 81 : 334 - 340
  • [19] M Awad Safaa, 2021, Pak J Biol Sci, V24, P1022, DOI 10.3923/pjbs.2021.1022.1033
  • [20] Accuracy of cystoscopy in predicting histologic features of bladder lesions
    Mitropoulos, D
    Kiroudi-Voulgari, A
    Nikolopoulos, P
    Manousakas, T
    Zervas, A
    [J]. JOURNAL OF ENDOUROLOGY, 2005, 19 (07) : 861 - 864