Ultrasensitive "signal-on" sandwich electrochemiluminescence immunosensor based on Pd@Au-L-cysteine enabled multiple-amplification strategy for Apolipoprotein-A1 detection

被引:8
作者
Qi, Jilan [1 ]
Zhang, Xiaolei [1 ]
Zhang, Qiangyan [1 ]
Xue, Ying [1 ]
Meng, Fei [1 ]
Liu, Yuanhua [2 ]
Yang, Gongjun [1 ]
机构
[1] China Pharmaceut Univ, Minist Educ, Sch Pharm, Key Lab Drug Qual Control & Pharmacovigilance, Nanjing 210009, Peoples R China
[2] Nanjing Med Univ, Affiliated Canc Hosp, Canc Inst Jiangsu Prov, Dept Chemotherapy, 42 Baiziting Raod, Nanjing 210009, Peoples R China
关键词
Electrochemiluminescence immunosensor; Apolipoprotein-A1; Zinc oxalate metal organic frameworks; L-cysteine; Pd@Au core-shell nanostructure; BLADDER-CANCER BIOMARKER; GRAPHENE OXIDE; IMMUNOASSAY; APO-A1; RU(BPY)(3)(2+); PLATFORM; COMPLEX;
D O I
10.1016/j.microc.2022.107409
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, a "signal on" electrochemiluminescence (ECL) strategy was proposed to detect Apolipoprotein-A1 (Apo-A1), a common tumor biomarker for bladder cancer. The tris(2,2 '-bipyridyl)-ruthenium(II) [Ru(bpy)32+] was used as luminophor captured by three-dimensional (3D) zinc oxalate metal-organic frameworks (MOFs), which constructed as the ECL nanoprobe (Ru-MOF) for detecting Apo-A1. Meanwhile, L-cysteine (L-Cys) as the co-reactant was connected to the Pd@Au core-shell nanostructure through Au-S bond, which was directly modified on the glassy carbon electrode (GCE) to significantly reduce the electron transfer distance between the luminophor and co-reactant. The ECL intensity was "signal on" when the ECL probe of Ru-MOF was linked to the electrode by the immunoreaction of antigen-antibody. Based on these principles, the quantitative relationship between the concentration of Apo-A1 and the ECL intensity was obtained in the range of 1.00 fg center dot mL-1 to 1.00 ng center dot mL-1 with a linear coefficient of 0.9968. The proposed ECL immunosensor showed some great advantages, such as simplification, rapidity, stability and selectivity. It was also successfully applied for the determination of Apo-A1 in real serum and urine samples with the recovery of 98.0% ~ 115.0% (RSD < 5.2%). To sum up, a "signal on" ECL immunosensor was successfully constructed for Apo-A1 detection, and it may facilitate the diagnosis of bladder cancer in clinic.
引用
收藏
页数:10
相关论文
共 38 条
  • [1] Surface Evolution of PtCu Alloy Shell over Pd Nanocrystals Leads to Superior Hydrogen Evolution and Oxygen Reduction Reactions
    Bao, Mingjun
    Amiinu, Ibrahim Saana
    Peng, Tao
    Li, Wenqian
    Liu, Shaojun
    Wang, Zhe
    Pu, Zonghua
    He, Daping
    Xiong, Yuli
    Mu, Shichun
    [J]. ACS ENERGY LETTERS, 2018, 3 (04): : 940 - 945
  • [2] Electrochemiluminescence immunosensor of "signal-off" for β-amyloid detection based on dual metal-organic frameworks
    Dong, Xue
    Zhao, Guanhui
    Li, Xuan
    Fang, Jinglong
    Miao, JunCong
    Wei, Qin
    Cao, Wei
    [J]. TALANTA, 2020, 208
  • [3] Ultrasensitive competitive method-based electrochemiluminescence immunosensor for diethylstilbestrol detection based on Ru(bpy)32+ as luminophor encapsulated in metal organic frameworks UiO-67
    Dong, Xue
    Zhao, Guanhui
    Liu, Li
    Li, Xuan
    Wei, Qin
    Cao, Wei
    [J]. BIOSENSORS & BIOELECTRONICS, 2018, 110 : 201 - 206
  • [4] Coreactant-Free and Label-Free Eletrochemiluminescence Immunosensor for Copeptin Based on Luminescent Immuno-Gold Nanoassemblies
    Han, Zhili
    Shu, Jiangnan
    Jiang, Qiaoshi
    Cui, Hua
    [J]. ANALYTICAL CHEMISTRY, 2018, 90 (10) : 6064 - 6070
  • [5] An ultrasensitive electrochemiluminescence immunoassay based on supersandwich DNA structure amplification with histidine as a co-reactant
    He, Ying
    Chai, Yaqin
    Yuan, Ruo
    Wang, Haijun
    Bai, Lijuan
    Cao, Yaling
    Yuan, Yali
    [J]. BIOSENSORS & BIOELECTRONICS, 2013, 50 : 294 - 299
  • [6] Bladder Cancer in 2010 How Far Have We Come?
    Jacobs, Bruce L.
    Lee, Cheryl T.
    Montie, James E.
    [J]. CA-A CANCER JOURNAL FOR CLINICIANS, 2010, 60 (04) : 244 - 272
  • [7] Self-enhanced N-(aminobutyl)-N-(ethylisoluminol) derivative-based electrochemiluminescence immunosensor for sensitive laminin detection using PdIr cubes as a mimic peroxidase
    Jiang, Xinya
    Wang, Huijun
    Wang, Haijun
    Zhuo, Ying
    Yuan, Ruo
    Chai, Yaqin
    [J]. NANOSCALE, 2016, 8 (15) : 8017 - 8023
  • [8] Electrochemiluminescence resonance energy transfer system between GNRs and Ru(bpy)32+: Application in magnetic aptasensor for β-amyloid
    Ke, Hong
    Sha, Haifeng
    Wang, Yinfang
    Guo, Weiwei
    Zhang, Xin
    Wang, Zhiming
    Huang, Chusen
    Jia, Nengqin
    [J]. BIOSENSORS & BIOELECTRONICS, 2018, 100 : 266 - 273
  • [9] Rapid energy transfer in non-porous metal-organic frameworks with caged Ru(bpy)32+ chromophores: oxygen trapping and luminescence quenching
    Kent, Caleb A.
    Liu, Demin
    Ito, Akitaka
    Zhang, Teng
    Brennaman, M. Kyle
    Meyer, Thomas J.
    Lin, Wenbin
    [J]. JOURNAL OF MATERIALS CHEMISTRY A, 2013, 1 (47) : 14982 - 14989
  • [10] Centimeter-Scale Pillared-Layer Metal-Organic Framework Thin Films Mediated by Hydroxy Double Salt Intermediates for CO2 Sensor Applications
    Kim, Ki-Joong
    Ellis, James E.
    Howard, Bret H.
    Ohodnicki, Paul R.
    [J]. ACS APPLIED MATERIALS & INTERFACES, 2021, 13 (01) : 2062 - 2071