Accuracies of β-lactam susceptibility test results for Pseudomonas aeruginosa with four automated systems (BD Phoenix, MicroScan WalkAway, Vitek, and Vitek 2)

被引:26
作者
Juretschko, Stefan
LaBombardi, Vincent J.
Lerner, Stephen A.
Schreckenberger, Paul C.
机构
[1] Arkansas Childrens Hosp, Little Rock, AR 72202 USA
[2] St Vincents Hosp & Med Ctr, New York, NY 10011 USA
[3] Wayne State Univ, Detroit Med Ctr, Detroit, MI 48201 USA
[4] Loyola Univ, Med Ctr, Maywood, IL 60153 USA
关键词
D O I
10.1128/JCM.01716-06
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Contemporary clinical isolates and challenge strains of Pseudomonas aeruginosa were tested by four automated susceptibility testing systems (BD Phoenix, MicroScan WalkAway, Vitek, and Vitek 2; two laboratories with each) against six broad-spectrum beta-lactams, and the results were compared to reference broth microdilution (BMD) and to consensus results from three validated methods (BMD, Etest [AB Biodisk, Solna, Sweden], and disk diffusion). Unacceptable levels of error (minor, major, and very major) were detected, some with systematic biases toward false susceptibility (piperacillin-tazobactam and imipenem) and others toward false resistance (aztreonam, cefepime, and ceftazidime). We encourage corrective action by the system manufacturers to address test biases, and we suggest that clinical laboratories using automated systems should consider accurate alternative methods for routine use.
引用
收藏
页码:1339 / 1342
页数:4
相关论文
共 19 条
[1]   INTERPRETIVE ERRORS USING AN AUTOMATED-SYSTEM FOR THE SUSCEPTIBILITY TESTING OF IMIPENEM AND AZTREONAM [J].
BIEDENBACH, DJ ;
JONES, RN .
DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 1995, 21 (01) :57-60
[2]  
Biedenbach DJ, 1999, DIAGN MICR INFEC DIS, V33, P305
[3]   Comparison of agar diffusion methodologies for antimicrobial susceptibility testing of Pseudomonas aeruginosa isolates from cystic fibrosis patients [J].
Burns, JL ;
Saiman, L ;
Whittier, S ;
Larone, D ;
Krzewinski, J ;
Liu, Z ;
Marshall, SA ;
JOnes, RN .
JOURNAL OF CLINICAL MICROBIOLOGY, 2000, 38 (05) :1818-1822
[4]   Comparison of two commercial systems (Vitek and MicroScan-WalkAway) for antimicrobial susceptibility testing of Pseudomonas aeruginosa isolates from cystic fibrosis patients [J].
Burns, JL ;
Saiman, L ;
Whittier, S ;
Krzewinski, J ;
Liu, ZL ;
Larone, D ;
Marshall, SA ;
Jones, RN .
DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2001, 39 (04) :257-260
[5]   Clinical evaluation of the Vitek automated system with cards GNS 122 and 127 and VTK-R07.01 software for antimicrobial susceptibility testing of Pseudomonas aeruginosa [J].
Chandler, LJ ;
Poulter, M ;
Reisner, B ;
Woods, G .
DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2002, 42 (01) :71-73
[6]  
*CLIN LAB STAND I, 2006, M100S16 CLSI
[7]  
Clinical and Laboratory Standards Institute, 2006, M2A9 CLSI
[8]  
Clinical and Laboratory Standards Institute, 2006, M7A7 CLSI
[9]  
*COLL AM PATH, 2004, SURV 2004 D C BACT F
[10]   Evaluation of the automated phoenix system for potential routine use in the clinical microbiology laboratory [J].
Donay, JL ;
Mathieu, D ;
Fernandes, P ;
Prégermain, C ;
Bruel, P ;
Wargnier, A ;
Casin, I ;
Weill, FX ;
Lagrange, PH ;
Herrmann, JL .
JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (04) :1542-1546