Fast Pediatric 3D Free-Breathing Abdominal Dynamic Contrast Enhanced MRI With High Spatiotemporal Resolution

被引:82
作者
Zhang, Tao [1 ]
Cheng, Joseph Y. [1 ]
Potnick, Aaron G. [1 ]
Barth, Richard A. [1 ]
Alley, Marcus T. [1 ]
Uecker, Martin [2 ]
Lustig, Michael [2 ]
Pauly, John M. [1 ]
Vasanawala, Shreyas S. [1 ]
机构
[1] Stanford Univ, Stanford, CA 94305 USA
[2] Univ Calif Berkeley, Berkeley, CA 94720 USA
基金
美国国家卫生研究院;
关键词
pediatric dynamic contrast enhanced abdominal MRI; parallel imaging; low rank; compressed sensing; MOTION CORRECTION; RECONSTRUCTION;
D O I
10.1002/jmri.24551
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo develop a method for fast pediatric 3D free-breathing abdominal dynamic contrast enhanced (DCE) magnetic resonance imaging (MRI) and investigate its clinical feasibility. Materials and MethodsA combined locally low rank parallel imaging method with soft gating is proposed for free-breathing DCE MRI acquisition. With Institutional Review Board (IRB) approval and informed consent/assent, 23 consecutive pediatric patients were recruited for this study. Free-breathing DCE MRI with approximate to 1 mm(3) spatial resolution and a 6.5-sec frame rate was acquired on a 3T scanner. Undersampled data were reconstructed with a compressed sensing method without motion correction (FB-CS) and the proposed method (FB-LR). A follow-up respiratory-triggered acquisition (RT-CS) was performed as a reference standard. The reconstructed images were evaluated independently by two radiologists. Wilcoxon tests were performed to test the hypothesis that there was no significant difference between different reconstructions. Quantitative evaluation of contrast dynamics was also performed. ResultsThe mean score of overall image quality of FB-LR was 4.0 on a 5-point scale, significantly better (P < 0.05) than FB-CS reconstruction (mean score 2.9), and similar to RT-CS (mean score 4.1). FB-LR also matched the temporal fidelity of contrast dynamics with a root mean square error less than 5%. ConclusionFast 3D free-breathing DCE MRI with high scan efficiency and image quality similar to respiratory-triggered acquisition is feasible in a pediatric clinical setting. J. Magn. Reson. Imaging 2015;41:460-473.(c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:460 / 473
页数:14
相关论文
共 44 条
[1]  
Alley M., 2011, Proceedings of the 19th Annual Meeting of ISMRM, P1218
[2]   Matrix description of general motion correction applied to multishot images [J].
Batchelor, PG ;
Atkinson, D ;
Irarrazaval, P ;
Hill, DLG ;
Hajnal, J ;
Larkman, D .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (05) :1273-1280
[3]   Hierarchical adaptive local affine registration for fast and robust respiratory motion estimation [J].
Buerger, Christian ;
Schaeffter, Tobias ;
King, Andrew P. .
MEDICAL IMAGE ANALYSIS, 2011, 15 (04) :551-564
[4]   A SINGULAR VALUE THRESHOLDING ALGORITHM FOR MATRIX COMPLETION [J].
Cai, Jian-Feng ;
Candes, Emmanuel J. ;
Shen, Zuowei .
SIAM JOURNAL ON OPTIMIZATION, 2010, 20 (04) :1956-1982
[5]   Exact Matrix Completion via Convex Optimization [J].
Candes, Emmanuel J. ;
Recht, Benjamin .
FOUNDATIONS OF COMPUTATIONAL MATHEMATICS, 2009, 9 (06) :717-772
[6]  
Cheng J., 2013, PROC INT SOC MAG RES, P312
[7]   Nonrigid motion correction in 3D using autofocusing withlocalized linear translations [J].
Cheng, Joseph Y. ;
Alley, Marcus T. ;
Cunningham, Charles H. ;
Vasanawala, Shreyas S. ;
Pauly, John M. ;
Lustig, Michael .
MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (06) :1785-1797
[8]  
Cheng JY, 2013, P ISMRM WORKSH DAT S
[9]   MR Imaging of the Abdomen and Pelvis in Infants, Children, and Adolescents [J].
Darge, Kassa ;
Anupindi, Sudha A. ;
Jaramillo, Diego .
RADIOLOGY, 2011, 261 (01) :12-29
[10]  
Doneva M., 2011, Proceedings of the 19th Annual Meeting of ISMRM, Montreal, Quebec, Canada, P3057