Cutting balloon angioplasty for undilatable venous stenoses causing dialysis graft failure

被引:34
作者
Bittl, JA [1 ]
Feldman, RL [1 ]
机构
[1] Munroe Reg Med Ctr, Ocala Heart Inst, Ocala, FL 34474 USA
关键词
hemodialysis; bridge graft; Brescia-Cimino fistula; percutaneous transluminal angioplasty; venous stenosis;
D O I
10.1002/ccd.10484
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Dialysis fistulas and bridge grafts frequently develop outflow stenoses in the venous limb, leading to graft failure. The venous stenoses are fibrotic and require percutaneous transluminal angioplasty with high-pressure balloons. We have encountered venous stenoses in 3 out of 219 hemodialysis patients with graft failure that were undilatable with 6-8 mm high-pressure balloons inflated to more than 24 atm. In each of these cases, treatment with a 4 mm cutting balloon successfully facilitated subsequent balloon dilation at lower pressures.
引用
收藏
页码:524 / 526
页数:3
相关论文
共 5 条
[1]  
[Anonymous], 2001, Am J Kidney Dis, V37, pS137
[2]  
Aruny JE., 1996, HDB INTERVENTIONAL R, P115
[3]   Percutaneous therapy of dialysis access failure [J].
Bittl, JA .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2002, 56 (02) :157-161
[4]   Longitudinal comparison of dialysis access methods: Risk factors for failure [J].
Hodges, TC ;
Fillinger, MF ;
Zwolak, RM ;
Walsh, DB ;
Bech, F ;
Cronenwett, JL .
JOURNAL OF VASCULAR SURGERY, 1997, 26 (06) :1009-1019
[5]  
2002, CUTTING BALLOON MONO