We present measurements on biomolecular surface multilayers using an integrated optical sensor based on the Mach-Zehnder interferometer (MZI). The sensor design is unique in that it incorporates a three-waveguide coupler structure at the interferometer output which gives advantages in terms of signal referencing and in establishing and maintaining a sensitive operating point. The sensor performance is characterized with respect to bulk superstrate index and by the formation of multiple protein adlayers using a biotin-avidin-based biochemical system. The detection limit for protein loading is estimated as 5 pg/mm(2).
引用
收藏
页码:583 / 592
页数:10
相关论文
共 50 条
  • [1] Integrated optical dual Mach-Zehnder interferometer sensor
    Hua, P
    Kawaguchi, K
    Wilkinson, JS
    CLEO(R)/PACIFIC RIM 2001, VOL I, TECHNICAL DIGEST, 2001, : 156 - 157
  • [2] Integrated optical dual Mach-Zehnder interferometer sensor
    Hua, P
    Luff, BJ
    Quigley, GR
    Wilkinson, JS
    Kawaguchi, K
    SENSORS AND ACTUATORS B-CHEMICAL, 2002, 87 (02) : 250 - 257
  • [3] Integrated optical Mach-Zehnder interferometers as simazine immunoprobes
    Drapp, B.
    Piehler, J.
    Brecht, A.
    Gauglitz, G.
    Luff, B.J.
    Wilkinson, J.S.
    Ingenhoff, J.
    Sensors and Actuators, B: Chemical, 1997, B39 (1 -3 pt 2) : 277 - 282
  • [4] New integrated-optical Mach-Zehnder modulator
    Tonchev, SH
    Kuneva, MK
    OPTOELECTRONIC INTEGRATED CIRCUITS IV, 2000, 3950 : 246 - 251
  • [5] Integrated optical Mach-Zehnder interferometers as simazine immunoprobes
    Drapp, B
    Piehler, J
    Brecht, A
    Gauglitz, G
    Luff, BJ
    Wilkinson, JS
    Ingenhoff, J
    SENSORS AND ACTUATORS B-CHEMICAL, 1997, 39 (1-3) : 277 - 282
  • [6] Design of Integrated Optical Mach-Zehnder Interferometer Biosensor for Ideal Surveillance Rapid Diagnostic Test
    Khor, Kang Nan
    Shahimin, Mukhzeer Mohamad
    2014 IEEE CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES), 2014, : 948 - 953
  • [7] Integrated Mach-Zehnder interferometer based on ARROW structures for biosensor applications
    Prieto, F
    Sepúlveda, B
    Calle, A
    Llobera, A
    Domínguez, C
    Lechuga, LM
    SENSORS AND ACTUATORS B-CHEMICAL, 2003, 92 (1-2) : 151 - 158
  • [8] Temperature stability of integrated optical asymmetric Mach-Zehnder modulators
    Zhou, Yi
    Qiu, Wei
    Chen, Yixin
    Zhongguo Jiguang/Chinese Journal of Lasers, 1994, 21 (02): : 102 - 105
  • [9] Optical refractometry using a, monolithically integrated Mach-Zehnder interferometer
    Maisenholder, B
    Zappe, HP
    Kunz, RE
    Moser, M
    Riel, P
    TRANSDUCERS 97 - 1997 INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS AND ACTUATORS, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 1997, : 79 - 80
  • [10] A GAS SENSOR BASED ON AN INTEGRATED OPTICAL MACH-ZEHNDER INTERFEROMETER
    FABRICIUS, N
    GAUGLITZ, G
    INGENHOFF, J
    SENSORS AND ACTUATORS B-CHEMICAL, 1992, 7 (1-3) : 672 - 676