The small-animal radiation research platform (SARRP): dosimetry of a focused lens system

被引:45
作者
Deng, Hua [1 ]
Kennedy, Christopher W.
Armour, Elwood
Tryggestad, Erik
Ford, Eric
McNutt, Todd
Jiang, Licai
Wong, John
机构
[1] Johns Hopkins Med, Dept Radiat Oncol & Mol Radiat Sci, Baltimore, MD 21218 USA
[2] OSMIC Inc, Auburn Hills, MI USA
关键词
D O I
10.1088/0031-9155/52/10/007
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A small animal radiation platform equipped with on-board cone-beam CT and conformal irradiation capabilities is being constructed for translational research. To achieve highly localized dose delivery, an x-ray lens is used to focus the broad beam from a 225 kVp x-ray tube down to a beam with a full width half maximum (FWHM) of approximately 1.5 mm in the energy range 40-80 keV. Here, we report on the dosimetric characteristics of the focused beam from the x-ray lens subsystem for high-resolution dose delivery. Using the metric of the average dose within a 1.5 mm diameter area, the dose rates at a source-to-surface distance (SSD) of 34 cm are 259 and 172 cGy min(-1) at 6 mm and 2 cm depths, respectively, with an estimated uncertainty of +/- 5%. The per cent depth dose is approximately 56% at 2 cm depth for a beam at 34 cm SSD.
引用
收藏
页码:2729 / 2740
页数:12
相关论文
共 11 条
[1]   A preliminary investigation of cell growth after irradiation using a modulated x-ray intensity pattern [J].
Bromley, Regina ;
Davey, Ross ;
Oliver, Lyn ;
Harvie, Rozelle ;
Baldock, Clive .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (15) :3639-3651
[2]   Weak energy dependence of EBT gafchromic film dose response in the 50 kVp-10 MVp X-ray range [J].
Butson, MJ ;
Cheung, T ;
Yu, PKN .
APPLIED RADIATION AND ISOTOPES, 2006, 64 (01) :60-62
[3]   Energy dependence of response of new high sensitivity radiochromic films for megavoltage and kilovoltage radiation energies [J].
Chiu-Tsao, ST ;
Ho, Y ;
Shankar, R ;
Wang, L ;
Harrison, LB .
MEDICAL PHYSICS, 2005, 32 (11) :3350-3354
[4]   Precise radiochromic film dosimetry using a flat-bed document scanner [J].
Devic, S ;
Seuntjens, J ;
Sham, E ;
Podgorsak, EB ;
Schmidtlein, CR ;
Kirov, AS ;
Soares, CG .
MEDICAL PHYSICS, 2005, 32 (07) :2245-2253
[5]  
Henke B. L., 1982, Atomic Data and Nuclear Data Tables, V27, P1, DOI 10.1016/0092-640X(82)90002-X
[6]   Normal tissue radiobiology: From the laboratory to the clinic [J].
Hill, RP ;
Rodemann, HP ;
Hendry, JH ;
Roberts, SA ;
Anscher, MS .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (02) :353-365
[7]  
ICRU, 1992, Photon, Electron, Proton and Neutron Interaction Data for Body Tissues
[8]   In-field and out-of-field effects in partial volume lung irradiation in rodents: Possible correlation between early dna damage and functional endpoints [J].
Moiseenko, VV ;
Battista, JJ ;
Hill, RP ;
Travis, EL ;
Van Dyk, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (05) :1539-1548
[9]   In vitro response of tumour cells to non-uniform irradiation [J].
Suchowerska, N ;
Ebert, MA ;
Zhang, M ;
Jackson, M .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (13) :3041-3051
[10]   HOW WATER EQUIVALENT ARE WATER-EQUIVALENT SOLID MATERIALS FOR OUTPUT CALIBRATION OF PHOTON AND ELECTRON-BEAMS [J].
TELLO, VM ;
TAILOR, RC ;
HANSON, WF .
MEDICAL PHYSICS, 1995, 22 (07) :1177-1189