Single photon emission computed tomography (SPELT) could achieve the functional image of the organ of interest, so the diseases can be found much earlier. Cone-beam SPELT reconstruction can improve the photo density and spatial resolution of the reconstructed image. A simple method for cone beam reconstruction is to rebin the cone-beam projection data into 2D sinograms and use 2D reconstruction method to obtain the 3D reconstructed images. In this paper, we proposed two rebinning methods for cone-beam SPELT reconstruction with non-uniform attenuation, these two algorithms both can obtain good reconstruction results, especially when reconstructed slice is close to the mid-plane.
引用
收藏
页码:337 / 340
页数:4
相关论文
共 50 条
  • [41] CONE BEAM SPECT RECONSTRUCTION WITH CAMERA TILT
    MANGLOS, SH
    JASZCZAK, RJ
    GREER, KL
    PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (05): : 625 - 631
  • [42] Cone fitted non-uniform prestress field
    He, Diqiu
    Qian, Yuqiang
    Jinshu Kuangshan/Metal Mine, 2000, (04): : 54 - 55
  • [43] Quantitative multi-pinhole small-animal SPECT: uniform versus non-uniform Chang attenuation correction
    Wu, C.
    de Jong, J. R.
    van Andel, H. A. Gratama
    van der Have, F.
    Vastenhouw, B.
    Laverman, P.
    Boerman, O. C.
    Dierckx, R. A. J. O.
    Beekman, F. J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (18): : N183 - N193
  • [44] Non-uniform attenuation correction in SPET using a modified conjugate gradient reconstruction method
    Knesaurek, K
    Machac, J
    NUCLEAR MEDICINE COMMUNICATIONS, 1997, 18 (05) : 431 - 436
  • [45] PRACTICAL ATTENUATION COMPENSATION METHOD FOR CONE BEAM SPECT.
    Manglos, Stephen H.
    Jaszczak, Ronald J.
    Floyd, Carey E.
    Greer, Kim L.
    Coleman, R.Edward
    IEEE Transactions on Nuclear Science, 1986, NS-34 (01) : 294 - 298
  • [46] Uniform LFM Reconstruction From Non-uniform Data
    Zhang, Xuebo
    Liu, Xvbo
    Jin, Zhou
    Liu, Yaqian
    2021 14TH INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING, BIOMEDICAL ENGINEERING AND INFORMATICS (CISP-BMEI 2021), 2021,
  • [47] Single-slice rebinning reconstruction in spiral cone-beam computed tomography
    Bruder, H
    Kachelriess, M
    Schaller, S
    Stierstorfer, K
    Flohr, T
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (09) : 873 - 887
  • [48] DIRECT CONE BEAM SPECT RECONSTRUCTION WITH CAMERA TILT
    LI, JY
    JASZCZAK, RJ
    GREER, KL
    COLEMAN, RE
    CAO, ZJ
    TSUI, BMW
    PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (02): : 241 - 258
  • [49] A RECONSTRUCTION ALGORITHM FOR HELICAL CONE-BEAM SPECT
    WENG, Y
    ZENG, GL
    GULLBERG, GT
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) : 1092 - 1101
  • [50] Image reconstruction from truncated data in SPECT with uniform attenuation
    Noo, Frederic
    Defrise, Michel
    Pack, Jed D.
    Clackdoyle, Rolf
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2288 - 2292