COVID-19 Biomarkers and Advanced Sensing Technologies for Point-of-Care (POC) Diagnosis

被引:27
作者
Etienne, Ernst Emmanuel [1 ]
Nunna, Bharath Babu [1 ,2 ]
Talukder, Niladri [1 ]
Wang, Yudong [1 ]
Lee, Eon Soo [1 ]
机构
[1] New Jersey Inst Technol, Adv Energy Syst & Microdevices Lab, Dept Mech & Ind Engn, Newark, NJ 07102 USA
[2] Harvard Univ, Div Engn Med, Dept Med, Brigham & Womens Hosp,Harvard Med Sch, Cambridge, MA 02139 USA
来源
BIOENGINEERING-BASEL | 2021年 / 8卷 / 07期
基金
美国国家科学基金会;
关键词
COVID-19; biomarkers; COVID-19 sensing techniques; biomarker detection; biomarker sensing; future diagnostic trends;
D O I
10.3390/bioengineering8070098
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
COVID-19, also known as SARS-CoV-2 is a novel, respiratory virus currently plaguing humanity. Genetically, at its core, it is a single-strand positive-sense RNA virus. It is a beta-type Coronavirus and is distinct in its structure and binding mechanism compared to other types of coronaviruses. Testing for the virus remains a challenge due to the small market available for at-home detection. Currently, there are three main types of tests for biomarker detection: viral, antigen and antibody. Reverse Transcription-Polymerase Chain Reaction (RT-PCR) remains the gold standard for viral testing. However, the lack of quantitative detection and turnaround time for results are drawbacks. This manuscript focuses on recent advances in COVID-19 detection that have lower limits of detection and faster response times than RT-PCR testing. The advancements in sensing platforms have amplified the detection levels and provided real-time results for SARS-CoV-2 spike protein detection with limits as low as 1 fg/mL in the Graphene Field Effect Transistor (FET) sensor. Additionally, using multiple biomarkers, detection levels can achieve a specificity and sensitivity level comparable to that of PCR testing. Proper biomarker selection coupled with nano sensing detection platforms are key in the widespread use of Point of Care (POC) diagnosis in COVID-19 detection.
引用
收藏
页数:27
相关论文
共 50 条
  • [41] COVID-19 point-of-care testing in care homes: what are the lessons for policy and practice?
    Buckle, Peter
    Micocci, Massimo
    Tulloch, John
    Kierkegaard, Patrick
    Parvulescu, Paula
    Thompson, Carl
    Spilsbury, Karen
    Allen, A. Joy
    Body, Richard
    Hayward, Gail
    Buchan, Iain
    Gordon, Adam L.
    [J]. AGE AND AGEING, 2021, 50 (05) : 1442 - 1444
  • [42] Emerging Trends of Gold Nanostructures for Point-of-Care Biosensor-Based Detection of COVID-19
    Yadav, Akhilesh Kumar
    Basavegowda, Nagaraj
    Shirin, Saba
    Raju, Shiji
    Sekar, Rajkumar
    Somu, Prathap
    Uthappa, U. T.
    Abdi, Gholamreza
    [J]. MOLECULAR BIOTECHNOLOGY, 2024, 67 (4) : 1398 - 1422
  • [43] Prospective selected biomarkers in COVID-19 diagnosis and treatment
    Tabassum, Tahani
    Rahman, Ahsab
    Araf, Yusha
    Ullah, Md A.
    Hosen, Mohammad J.
    [J]. BIOMARKERS IN MEDICINE, 2021, 15 (15) : 1435 - 1449
  • [44] Point-of-Care Biosensor-Based Diagnosis of COVID-19 Holds Promise to Combat Current and Future Pandemics
    Parihar, Arpana
    Ranjan, Pushpesh
    Sanghi, Sund K.
    Srivastava, Avanish K.
    Khan, Raju
    [J]. ACS APPLIED BIO MATERIALS, 2020, 3 (11) : 7326 - 7343
  • [45] Graphene-based hybrid electrical-electrochemical point-of-care device for serologic COVID-19 diagnosis
    Mattioli, Isabela A.
    Castro, Karla R.
    Macedo, Lucyano J. A.
    Sedenho, Graziela C.
    Oliveira, Mona N.
    Todeschini, Iris
    Vitale, Phelipe M.
    Ferreira, Suzete Cleusa
    Manuli, Erika R.
    Pereira, Geovana M.
    Sabino, Ester C.
    Crespilho, Frank N.
    [J]. BIOSENSORS & BIOELECTRONICS, 2022, 199
  • [46] Delayed Diagnosis of Shoulder Septic Arthritis and Osteomyelitis During the COVID-19 Pandemic: The Role of Point-of-Care Ultrasound
    Driver, Lachlan
    McFadden, Kathleen
    Al Jalbout, Nour
    Shokoohi, Hamid
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (02)
  • [47] Magnetofluidic immuno-PCR for point-of-care COVID-19 serological testing
    Zhang, Pengfei
    Chen, Liben
    Hu, Jiumei
    Trick, Alexander Y.
    Chen, Fan-En
    Hsieh, Kuangwen
    Zhao, Yang
    Coleman, Branch
    Kruczynski, Kate
    Pisanic, Thomas R.
    Heaney, Christopher D.
    Clarke, William A.
    Wang, Tza-Huei
    [J]. BIOSENSORS & BIOELECTRONICS, 2022, 195
  • [48] Diagnostic yield of point-of-care ultrasound imaging of the lung in patients with COVID-19
    Gil-Rodrigo, Adriana
    Llorens, Pere
    Martinez-Buendia, Carmen
    Luque-Hernandez, Maria-Jose
    Espinosa, Begona
    Manuel Ramos-Rincon, Jose
    [J]. EMERGENCIAS, 2020, 32 (05): : 340 - 344
  • [49] Merging microfluidics with luminescence immunoassays for urgent point-of-care diagnostics of COVID-19
    Yuan, Huijuan
    Chen, Peng
    Wan, Chao
    Li, Yiwei
    Liu, Bi-Feng
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2022, 157
  • [50] Performance of the Flash10 COVID-19 point-of-care molecular test
    Li, Runqing
    Zhao, Xiuying
    Jiang, Kai
    Tang, Jie
    Yang, Song
    Hu, Jing
    Ma, Xuzhu
    [J]. SCIENTIFIC REPORTS, 2024, 14 (01):