ANALYTICAL VALIDATION METHOD FOR THE DETERMINATION OF SULFONYLUREA HERBICIDES IN WATER SAMPLES BY SOLID-PHASE EXTRACTION AND HPLC WITH DIODE-ARRAY DETECTION

被引:0
|
作者
Grahovac, N. [1 ]
Suturovic, Z.
Kondic-Spika, A. [1 ]
Sekulic, P.
Lazic, S.
Sunjka, D.
Jaksic, S. [1 ]
机构
[1] Inst Field & Vegetables Crops, Novi Sad 21000, Serbia
来源
PROCEEDINGS OF THE 13TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND TECHNOLOGY | 2013年
关键词
sulfonylurea herbicides; determination; surface water; HPLC-DAD; SOILS;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Pesticides having different structures and biological activities are widely used for agricultural and non-agricultural purposes. Due to their widespread use, pesticides need to be determined in various environmental matrices. A wide range of analytical techniques have been developed in order to identify the organic contaminants often present at trace levels in environmental samples. The aim of this work was to develop a reliable, rapid, robust and cost-effective method for the determination of five sulfonylurea herbicides (nicosulfuron, oxasulfuron, tribenuron methyl, triasulfuron and tritosulfuron) in spiked river water samples. The samples were diluted with 0.5% acetic acid (1:1) and purified by solid-phase extraction (SPE) on Oasis MAX cartridges. After the cartridges were sequentially washed with water, methanol, ethyl acetate, and acetonitrile, they were eluted with 0.1% formic acid in acetonitrile. Elutes were evaporated to dryness and reconstituted in acetonitrile. The purified extracts were analyzed by reversed-phase high-performance liquid chromatography with diode-array detection (HPLC-DAD) system. The best separation was achieved on a Zorbax Eclipse XDB-C-18 (50mm x 4.6mm x 1.8 mu m) analytical column with gradient elution at a flow rate of 1 mL/min. The analyte was monitored at 230 nm. The linearity of calibration curve within the tested concentration range exhibited correlation coefficients (r(2)) higher than 0.998. The accuracy of the method was acceptable since the average recoveries measured at two fortification levels were in the range of 92.5-97.5% (n=3). The precision of the developed procedure expressed as the relative standard deviations (RSDs) were lower than 4.76% in all cases. The repeatability of the retention time and peak area was checked by injecting standard solution ten times. The relative standard deviation of the retention time and the peak area was found to be less than 0.2% and 0.6%, respectively. The method was also validated by analyzing freshly spiked river water samples. The proposed analytical method might be successfully applied in monitoring of sulfonylurea herbicides (nicosulfuron, oxasulfuron, tribenuron methyl, triasulfuron and tritosulfuron) in surface water and groundwater samples.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Molecularly imprinted polymer layer-coated silica nanoparticles toward dispersive solid-phase extraction of trace sulfonylurea herbicides from soil and crop samples
    Peng, Yan
    Xie, Ying
    Luo, Jing
    Nie, Li
    Chen, Yun
    Chen, Lina
    Du, Shuhu
    Zhang, Zhongping
    ANALYTICA CHIMICA ACTA, 2010, 674 (02) : 190 - 200
  • [42] Simple and sensitive determination of atrazine and its toxic metabolites in environmental water by carboxyl modified polyacrylonitrile nanofibers mat-based solid-phase extraction coupled with liquid chromatography-diode array detection
    Cao, Weixin
    Yang, Biyi
    Qi, Feifei
    Qian, Liangliang
    Li, Jian
    Lu, Lingeng
    Xu, Qian
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1491 : 16 - 26
  • [43] Rapid determination of sixteen sulfonylurea herbicides in surface water by solid phase extraction cleanup and ultra-high-pressure liquid chromatography coupled with tandem mass spectrometry
    Yan, Cuimin
    Zhang, Beibei
    Liu, Wenyuan
    Feng, Feng
    Zhao, Yonggang
    Du, Hui
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (30): : 3484 - 3489
  • [44] Continuous solid-phase extraction and gas chromatography-mass spectrometry determination of pharmaceuticals and hormones in water samples
    Azzouz, A.
    Souhail, B.
    Ballesteros, E.
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (17) : 2956 - 2963
  • [45] APPLICATION OF THE COMBINED USE OF HPLC DIODE-ARRAY DETECTION AND CAPILLARY GC NITROGEN PHOSPHORUS DETECTION FOR THE RAPID ANALYSIS OF ILLICIT HEROIN AND COCAINE SAMPLES
    HERNANDEZ, AF
    PLA, A
    MOLIZ, J
    GIL, F
    GONZALVO, MC
    VILLANUEVA, E
    JOURNAL OF FORENSIC SCIENCES, 1992, 37 (05) : 1276 - 1282
  • [46] A "half" core-shell magnetic nanohybrid composed of zeolitic imidazolate framework and graphitic carbon nitride for magnetic solid-phase extraction of sulfonylurea herbicides from water samples followed by LC-MS/MS detection
    Qi, Yan
    Wan, Mengfei
    El-Aty, A. M. Abd
    Li, Hui
    Cao, Liping
    She, Yongxin
    Shao, Yong
    Jin, Fen
    Wang, Shanshan
    Wang, Jing
    MICROCHIMICA ACTA, 2020, 187 (05)
  • [47] On-line coupling of automatic solid-phase extraction and HPLC for determination of carotenoids in serum
    Ferreiro-Vera, C.
    Mata-Granados, J. M.
    Quesada Gomez, J. M.
    Luque de Castro, M. D.
    TALANTA, 2011, 85 (04) : 1842 - 1847
  • [48] A “half” core-shell magnetic nanohybrid composed of zeolitic imidazolate framework and graphitic carbon nitride for magnetic solid-phase extraction of sulfonylurea herbicides from water samples followed by LC-MS/MS detection
    Yan Qi
    Mengfei Wan
    A. M. Abd El-Aty
    Hui Li
    Liping Cao
    Yongxin She
    Yong Shao
    Fen Jin
    Shanshan Wang
    Jing Wang
    Microchimica Acta, 2020, 187
  • [49] Dispersive solid-phase extraction followed by dispersive liquid-liquid microextraction for the determination of some sulfonylurea herbicides in soil by high-performance liquid chromatography
    Wu, Qiuhua
    Wang, Chun
    Liu, Zhimei
    Wu, Chunxia
    Zeng, Xin
    Wen, Jialin
    Wang, Zhi
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (29) : 5504 - 5510
  • [50] Determination of Polycyclic Aromatic Hydrocarbons in Water Samples Using Solid-Phase Extraction Procedure and High-Performance Liquid Chromatography With Fluorescence Detection
    Ghanmi, Safouane
    Ben Hassine, Sihem
    Bouabdallah, Sondes
    Driss, Mohamed Ridha
    Touil, Soufiane
    SEPARATION SCIENCE PLUS, 2025, 8 (01):