ANALYTICAL VALIDATION METHOD FOR THE DETERMINATION OF SULFONYLUREA HERBICIDES IN WATER SAMPLES BY SOLID-PHASE EXTRACTION AND HPLC WITH DIODE-ARRAY DETECTION

被引:0
|
作者
Grahovac, N. [1 ]
Suturovic, Z.
Kondic-Spika, A. [1 ]
Sekulic, P.
Lazic, S.
Sunjka, D.
Jaksic, S. [1 ]
机构
[1] Inst Field & Vegetables Crops, Novi Sad 21000, Serbia
来源
PROCEEDINGS OF THE 13TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND TECHNOLOGY | 2013年
关键词
sulfonylurea herbicides; determination; surface water; HPLC-DAD; SOILS;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Pesticides having different structures and biological activities are widely used for agricultural and non-agricultural purposes. Due to their widespread use, pesticides need to be determined in various environmental matrices. A wide range of analytical techniques have been developed in order to identify the organic contaminants often present at trace levels in environmental samples. The aim of this work was to develop a reliable, rapid, robust and cost-effective method for the determination of five sulfonylurea herbicides (nicosulfuron, oxasulfuron, tribenuron methyl, triasulfuron and tritosulfuron) in spiked river water samples. The samples were diluted with 0.5% acetic acid (1:1) and purified by solid-phase extraction (SPE) on Oasis MAX cartridges. After the cartridges were sequentially washed with water, methanol, ethyl acetate, and acetonitrile, they were eluted with 0.1% formic acid in acetonitrile. Elutes were evaporated to dryness and reconstituted in acetonitrile. The purified extracts were analyzed by reversed-phase high-performance liquid chromatography with diode-array detection (HPLC-DAD) system. The best separation was achieved on a Zorbax Eclipse XDB-C-18 (50mm x 4.6mm x 1.8 mu m) analytical column with gradient elution at a flow rate of 1 mL/min. The analyte was monitored at 230 nm. The linearity of calibration curve within the tested concentration range exhibited correlation coefficients (r(2)) higher than 0.998. The accuracy of the method was acceptable since the average recoveries measured at two fortification levels were in the range of 92.5-97.5% (n=3). The precision of the developed procedure expressed as the relative standard deviations (RSDs) were lower than 4.76% in all cases. The repeatability of the retention time and peak area was checked by injecting standard solution ten times. The relative standard deviation of the retention time and the peak area was found to be less than 0.2% and 0.6%, respectively. The method was also validated by analyzing freshly spiked river water samples. The proposed analytical method might be successfully applied in monitoring of sulfonylurea herbicides (nicosulfuron, oxasulfuron, tribenuron methyl, triasulfuron and tritosulfuron) in surface water and groundwater samples.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Development and optimization of the determination of pharmaceuticals in water samples by SPE and HPLC with diode-array detection
    Pavlovic, Dragana Mutavdzic
    Asperger, Danijela
    Tolic, Dijana
    Babic, Sandra
    JOURNAL OF SEPARATION SCIENCE, 2013, 36 (18) : 3042 - 3049
  • [2] Development and validation of a solid-phase extraction method coupled to high-performance liquid chromatography with ultraviolet-diode array detection for the determination of sulfonylurea herbicide residues in bovine milk samples
    Seccia, Serenella
    Albrizio, Stefania
    Fidente, Paola
    Montesano, Domenico
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (09) : 1253 - 1259
  • [3] Solid-phase extraction of sulfonylurea herbicides from water samples with single-walled carbon nanotubes disk
    Niu, Hongyun
    Shi, Yali
    Cai, Yaqi
    Wei, Fusheng
    Jiang, Guibin
    MICROCHIMICA ACTA, 2009, 164 (3-4) : 431 - 438
  • [4] Solid-phase extraction of sulfonylurea herbicides from water samples with single-walled carbon nanotubes disk
    Hongyun Niu
    Yali Shi
    Yaqi Cai
    Fusheng Wei
    Guibin Jiang
    Microchimica Acta, 2009, 164 : 431 - 438
  • [5] Magnetic polydopamine modified with deep eutectic solvent for the magnetic solid-phase extraction of sulfonylurea herbicides in water samples
    Wang, Dan-Dan
    Zhao, Yue
    Yang, Mei-Nan Ou
    Guo, Hao-Ming
    Yang, Zhong-Hua
    JOURNAL OF CHROMATOGRAPHY A, 2019, 1601 : 53 - 59
  • [6] Determination of sulfonylurea herbicides in soil extracts by solid-phase extraction and capillary zone electrophoresis
    Chen, ZL
    Kookana, RS
    Naidu, R
    CHROMATOGRAPHIA, 2000, 52 (3-4) : 142 - 146
  • [7] Determination of sulfonylurea herbicides in soil extracts by solid-phase extraction and capillary zone electrophoresis
    Z. L. Chen
    R. S. Kookana
    R. Naidu
    Chromatographia, 2000, 52 : 142 - 146
  • [8] Trace analysis of sulfonylurea herbicides in water samples by solid-phase extraction and liquid chromatography-tandem mass spectrometry
    Fenoll, Jose
    Hellin, Pilar
    Sabater, Paula
    Flores, Pilar
    Navarro, Simon
    TALANTA, 2012, 101 : 273 - 282
  • [9] Analysis of etorphine in postmortem samples by HPLC with UV diode-array detection
    Elliott, SP
    Hale, KA
    FORENSIC SCIENCE INTERNATIONAL, 1999, 101 (01) : 9 - 16
  • [10] Determination of Sulfonylurea Herbicides in Grain Samples by Matrix Solid-Phase Dispersion with Mesoporous Structured Molecularly Imprinted Polymer
    Ting Liang
    Lei Gao
    Dongli Qin
    Ligang Chen
    Food Analytical Methods, 2019, 12 : 1938 - 1948