Pre-tension effects from tightening the ligature on spinous process fracture risk in interspinous process device implantation

被引:7
作者
Park, Won Man [1 ]
Choi, Dae Kyung [1 ]
Kim, Yoon Hyuk [1 ]
Kim, Kyungsoo [2 ]
机构
[1] Kyung Hee Univ, Dept Mech Engn, Yongin 446701, Gyeonggi Do, South Korea
[2] Kyung Hee Univ, Dept Appl Math, Yongin 446701, Gyeonggi Do, South Korea
关键词
Lumbar spine; Biomechanics; Finite element analysis; Interspinous process device; Pre-tension of ligature; FINITE-ELEMENT-ANALYSIS; LUMBAR MOTION SEGMENT; MECHANICAL RESPONSE; ADJACENT SEGMENTS; ANNULUS FIBROSUS; IN-VITRO; DISC; COMPLICATIONS; INSTABILITY; BEHAVIOR;
D O I
10.1007/s12541-014-0632-2
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Ligatures are used with many types of interspinous process devices to prevent instability in flexion movement by wrapping around upper and lower spinous processes. In this study, the effects of the pre-tension by tightening the ligature on the spinous process fracture were investigated using a finite element method. Five different interspinous process devices, Coflex-F-A (R), Wallis((TM)), Diam((TM)), Viking, and Spear(A (R)), were chosen, and implanted after creating a defect consisting of bilateral facetectomy with a resection of the ligamentum flavum. Flexion and extension motions were simulated with various pre-tension values of the ligatures in the range of 0 to 400 N at 100 N increments. While stability at the surgical level in the flexion increased with increasing pre-tension of the ligatures, the spinous process fracture risk also increased with increasing ligature pre-tension. Furthermore, the fatigue life of the spinous process also decreased. Thus, the amount of pre-tension of the ligatures should be carefully selected depending on the materials and design of implants.
引用
收藏
页码:2597 / 2604
页数:8
相关论文
共 32 条
  • [1] ANALYSIS OF COMPLICATIONS IN PATIENTS TREATED WITH THE X-STOP INTERSPINOUS PROCESS DECOMPRESSION SYSTEM: PROPOSAL FOR A NOVEL ANATOMIC SCORING SYSTEM FOR PATIENT SELECTION AND REVIEW OF THE LITERATURE
    Barbagallo, Giuseppe M. V.
    Olindo, Giuseppe
    Corbino, Leonardo
    Albanese, Vincenzo
    [J]. NEUROSURGERY, 2009, 65 (01) : 111 - 120
  • [2] Beer F. P., 2009, MECH MATER, P60
  • [3] Biomechanics of the lumbar spine after dynamic stabilization
    Bellini, Chiara Maria
    Galbusera, Fabio
    Raimondi, Manuela T.
    Mineo, Gittseppe V.
    Brayda-Bruno, Marco
    [J]. JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2007, 20 (06): : 423 - 429
  • [4] Dynamic interspinous process stabilization: review of complications associated with the X-Stop device
    Bowers, Christian
    Amini, Amin
    Dailey, Andrew T.
    Schmidt, Meic H.
    [J]. NEUROSURGICAL FOCUS, 2010, 28 (06) : 1 - 6
  • [5] Creep contributes to the fatigue behavior of bovine trabecular bone
    Bowman, SM
    Guo, XE
    Cheng, DW
    Keaveny, TM
    Gibson, LJ
    Hayes, WC
    McMahon, TA
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1998, 120 (05): : 647 - 654
  • [6] Multi-segment FEA of the human lumbar spine including the heterogeneity of the annulus fibrosus
    Eberlein, R
    Holzapfel, GA
    Fröhlich, M
    [J]. COMPUTATIONAL MECHANICS, 2004, 34 (02) : 147 - 163
  • [7] Kinematic evaluation of lumbar fusion techniques
    Esses, SI
    Doherty, BJ
    Crawford, MJ
    Dreyzin, V
    [J]. SPINE, 1996, 21 (06) : 676 - 684
  • [8] Interspinous spacers in the treatment of degenerative lumbar spinal disease: our experience with DIAM and Aperius devices
    Fabrizi, Antonio P.
    Maina, Raffaella
    Schiabello, Luigi
    [J]. EUROPEAN SPINE JOURNAL, 2011, 20 : 20 - 26
  • [9] INTERLAMINAR SHEAR STRESSES AND LAMINAE SEPARATION IN A DISC - FINITE-ELEMENT ANALYSIS OF THE L3-L4 MOTION SEGMENT SUBJECTED TO AXIAL COMPRESSIVE LOADS
    GOEL, VK
    MONROE, BT
    GILBERTSON, LG
    BRINCKMANN, P
    NAT, R
    [J]. SPINE, 1995, 20 (06) : 689 - 698
  • [10] Hilibrand Alan S, 2004, Spine J, V4, p190S, DOI 10.1016/j.spinee.2004.07.007